Symptoms of faults in Proterm floor-standing boilers and how to repair them
![]()

Proterm gas boilers are popular with consumers for their reliability, European quality and reasonable price. Among floor-standing models, the Bear series is well known, whilst among wall-mounted models, the Cheetah range is considered the most versatile. Models with the letter code MOV are fitted with an open combustion chamber, whilst those with the code MTV are fitted with a closed combustion chamber. Consider how to set up Proterm gas boilers.
Proterm Cheetah heating modes
The Proterm Cheetah gas boiler can operate in several modes:
- “Heating” – press the MODE button once and the display will show the “radiator” symbol along with the current pressure reading in the heating system. In this mode, the unit operates solely to provide heating, whilst the DHW function is switched off.
- “Summer” – activated by pressing MODE twice. The display shows the pressure in the heating system together with the “tap with a drop of water” symbol. In this mode, the boiler operates solely to supply hot water.
- “Holiday” – press the MODE button three times and the OFF symbol will appear on the pressure display. In this mode, the heating and domestic hot water systems are not operational, but all the appliance’s safety features remain active.

The desired heating or hot water temperature can be adjusted using the ‘+’ and ‘-’ buttons.
The settings are configured as follows:
- The DHW temperature is controlled as follows: when the ‘+’ or ‘-’ button is pressed, the ‘tap with a drop of water’ symbol and ‘ºC’ begin to flash. The desired temperature can be set within a range of 38ºC to 60ºC.
- The heating temperature can also be adjusted using the ‘+’ and ‘-’ buttons. After pressing one of them, press the MODE button; the ‘radiator’ symbol and ‘ºC’ will flash. Then use the “+” and “-” buttons to set the optimum heat transfer fluid temperature within the range of 38–85ºC.

Operating a Proterm Cheetah gas boiler without thermostats is not particularly economical. To maximise savings, it is recommended that you purchase a room thermostat.
Documents relating to this issue



The boiler is installed in a frost-protected room near the flue. The permissible ambient temperature for boiler operation is between +3°C and +45°C.
The combustion air supplied to the appliance must be technically free of chemicals that may contain, for example, fluorine, chlorine or sulphur. Aerosols, paints, solvents, cleaning agents and adhesives contain substances that may cause corrosion when the appliance is operated under adverse conditions, including within the flue system. The combustion air must not contain mechanical impurities, e.g. building dust, sand, etc.
For the extraction of combustion products from PROTHERM 20, 30, 40 and 50 KLZ boilers, the ‘PROTHERM PT 20 (30, 40, 50) SEMITURBO’ accessory can be used, which ensures forced extraction of combustion products.
This device enables cast-iron boilers to be operated in situations where it is not possible to use a standard flue gas outlet into a chimney. The extension is connected to the boiler’s flue gas outlet. The extension’s flue gas outlet allows the use of components from the Protherm chimney catalogue for wall-mounted boilers.
The maximum length of the flue is 10 equivalent metres (1 equivalent metre = 1 metre of straight pipe or one 90° elbow).
PLEASE NOTE:
When using the PROTHERM PT 20 (30, 40, 50) fan extension, the flue gas thermostat terminals must be bypassed before starting the boiler. In this operating mode, the air pressure switch – which is included with the PT 20 (30–50) chimney extension – acts as a safety feature. The boiler extension may only be installed and operated by a specialist from a Protherm-certified organisation.
When carrying out maintenance work whilst the fan extension is connected to the mains (even if the mains switch is turned off), you must follow the safety instructions!
It is advisable to monitor any deviation from the initial water pressure in the heating system using the pressure gauge on the boiler control panel, as indicated by the red arrow on the gauge. If the pressure in the heating system drops, locate and repair any leaks, bleed the heating system, or check the expansion tank.
The boiler expansion vessel must be adjusted in accordance with the parameters of the heating system – this ensures that the heating system and all its components are protected during operation against undesirable stress caused by sudden changes in pressure.
When filling the built-in DHW boiler, you must open the cold water inlet to the boiler and the DHW outlet pipe from the boiler. As soon as water begins to flow out of the DHW pipe, this means that the boiler is completely filled with water.
Note:

It is recommended to install a slag trap from the heating system upstream of the boiler (i.e. on the return pipe of the heating system). The slag trap may be combined with a sump; it must be fitted with access hatches.






How does the Proterm Cheetah work when connecting thermostats?
When operating the Protrem Cheetah gas boiler without a room thermostat, the heating of the rooms depends on the temperature setting of the heating medium.
Once the Proterm gas boiler has been connected to a thermostat, you can set the desired heating temperature. This must be set at a level that the unit can maintain, regardless of the outside temperature. The controller will only regulate the heating within the selected range.
Please note! In the room where the room controller is installed, radiators must not be fitted with thermostatic valves.
The Proterm unit, fitted with an on/off controller, is capable of maintaining the set heating temperature. The boiler receives a signal to switch on or off depending on the temperature in the room where the controller is located.
Once connected to the gas appliance’s continuous-control regulator, the output will vary continuously to maintain the set room temperature.
The room thermostat will regulate the temperature in the room and send a signal to the unit to switch it off if the temperature reaches the set point, or to switch it on if the temperature drops.

Equithermal control is the most advanced and accurate method … It is carried out by a thermostat fitted with an outdoor temperature sensor. When such a device is connected to a gas boiler, the boiler will regulate the temperature of the coolant depending on outdoor conditions.
If the unit is controlled by an equithermal controller, it is not recommended to set the maximum coolant temperature – this will significantly reduce the system’s efficiency.
Installation of a Proterm Medved gas boiler
The Proterm Medved floor-standing gas boiler has a simple design. Models are available that provide heating only, whilst others also produce hot water. Depending on its specifications, the Proterm Medved gas boiler is configured as follows:
- DHW temperature – press the MODE button; the indicator light in the top left-hand corner will start to flash and another LED will light up in the bottom right-hand corner. Use the button with the two upward-pointing arrows to set the desired boiler temperature within the range of 40–70°C. Confirm the selected temperature by pressing the MODE button.
- Heat transfer fluid temperature – in heating temperature setting mode, the indicator light flashes in the top left-hand corner. Use the button with the two upward-pointing arrows to set the desired heat transfer fluid temperature within the range of 45–85 ºC. Press the MODE button to confirm the selected value.
The temperature list includes the parameter -. When this is selected, the gas boiler switches to summer mode, in which the heating is switched off and the hot water supply remains operational.

When connecting an equithermal temperature controller to the boiler, additional settings must be made.
Symptoms of faults in Proterm floor-standing boilers and how to repair them
How do I adjust the gas valve on a Protherm Cheetah 23 MTV boiler? Error F28 – failed first ignition attempt. I took it apart a few times, did a bit of work on it, and it started up again. It’s not clear how to adjust the safety valve; it twists and sometimes unscrews. And how do you install the gas flow valve? The gas valve is configured via the service menu. A pressure gauge is connected and the maximum and minimum gas pressures are set. During boiler operation, the coolant temperature rises and the unit uses the gas valve to reduce the gas pressure at the burner (solenoid valve or stepper motor) – the flame is modulated. It is reduced to certain limits. If these limits are not sufficient, the coolant overheats and the unit switches off due to overheating. It then cools down and switches on again, beginning to cycle on and off. Conclusion: you must set the minimum gas pressure. As for the safety valve, it should hold at 3 bar and should not leak. Why is the Jaguar 24 JTV boiler displaying error F01? How can I fix this?
Error F01 indicates an overheating fault. When the water temperature in the heating system exceeds 98°C, the unit switches off and the RESET indicator and error code F01 appear on the display simultaneously. Open the unit; there is a button in the top right-hand corner that clears the error.
The Panther 30 KOV model is displaying error F6. A gas leak occurred during the first start-up. When the unit ignited, there was a flash. What is the cause? Error F6 indicates a fault with the internal flue gas sensor. This may be caused by the following reasons: A faulty sensor. Incorrect electrical connection. A faulty cable. Furthermore,
Could you advise on how to reduce the pressure in a Protherm 30 KLOM floor-standing gas boiler? And is it permitted to reduce the gas pressure? Does the unit have a regulator that adjusts the pressure of the gas mixture, or is this adjustment not necessary? The regulator must adjust the pressure of the fuel supplied to the boiler. If the pressure is too low, the burner will not ignite; if it is too high, you may notice the burner separating from the wick and the burner going out immediately after ignition. Here are the corrective steps. Preheat the boiler thoroughly. Open the flue gas outlet fully. Turn the main burner up to maximum; during this time, the flame will turn blue-yellow. Close the gas supply valve, which will extinguish the yellow flame. Then check the boiler’s operation in various modes. The Proterm 40 KLZ boiler begins to hum and heats up thoroughly, whilst the non-return valve is leaking. What is the fault? If the boiler unit has been connected correctly, the first thing to check is the expansion tank. There may be situations where it is more appropriate to relocate it to a different position. In addition, adjustments are made directly on the unit. In particular, the circulation of the coolant is checked or the gas valve is adjusted, as its incorrect setting is the cause of these operational difficulties. We had a Proterm Volk 16 KSO boiler installed at home. After a year of satisfactory operation, the pressure in the system began to drop. The expansion tank was drained of fluid, then pumped out and refilled with water. Everything was carried out according to the instructions, but after a short time the pressure began to drop again. No leaks were found in the system. We tried fitting a new valve, but it does not work. Why is the boiler unable to maintain the correct pressure? How do you test and adjust the expansion tank? There is no need to drain the heating medium from the heating circuit. Switch off the boiler. Then disconnect the valve nipple located on the expansion tank. If water starts to flow, the expansion tank must be replaced as appropriate. Once air begins to flow, the shut-off valve closes and the drain valve opens, allowing the coolant to be drained from the unit. Once the water has stopped flowing, connect a pump fitted with a pressure gauge to the connection and pump up to the pressure specified in the manual. Repeat this operation two or three times, as a small amount of fluid is regularly discharged during pumping, causing the pressure to drop. You must continue pumping until the pressure drop and water leakage stop. Then turn the cap back on, open the taps and fill the system with coolant. Switch on the unit and use the air bleed valve to remove any excess air from the system.
Please tell me, why does the Gepard 23 MTV boiler display error F75? It often switches off and the F75 error light comes on. How can I fix this? Error F75 appears after the pump has started five times without detecting a pressure increase of more than 50 mbar. The first step is probably to check the system for leaks. Suddenly, there’s a leak somewhere and there’s simply no pressure (or rather, just atmospheric pressure). If everything is in order, then a faulty sensor is most likely to blame. We installed a Proterm 23 MTV boiler. Almost immediately, error code F62 started to appear. Sometimes 1–3 times a day. Sometimes once every 2–3 days. After a restart, the unit starts up again. Winter is approaching – what should we do? How can I reset the error?
Error code F62 means that the gas valve is closed. These heating models do indeed have a gas valve that tends to stick. It is possible that the valve is working correctly but has been fitted incorrectly. Perhaps something is preventing it from working normally and stopping it from shutting off the gas in time. In all likelihood, you’ll need to lubricate the gas valve so that it doesn’t stick during operation and no longer causes this fault. What caused the appliance to click whilst operating at the set temperature? Let’s assume that the gas burner ignites, the temperature rises, and then a strange metallic clacking sound is heard. However, if you remove the screws securing the front panel, the knocking does not occur in this case. What has happened? From time to time, the appliance starts to crackle, rattle and pop, most often after the main gas burner has been switched off. A key cause of this fault is the uneven heating of the heat exchanger surfaces due to blockages or limescale build-up. You urgently need to clean the boiler. The Bear 60 PLO gas boiler won’t start. The gas burner assembly is in operating mode if you hold down the power button. However, the unit switches off as soon as you release the button. What is the cause of the fault? The problem is most likely a faulty thermocouple or a faulty gas valve. Alternatively, it could be the supply pipe. The gas pressure may be low, or the control board’s voltage may be very low. The flame has started to smoke heavily and the gas burner continues to burn constantly; it won’t go out. The temperature cannot rise above the set level, yet the flame continues to burn. There is a lot of soot on parts of the unit. The gas supplier claims this is due to a lack of draught. What can be done? Most likely, the air flow has decreased. Maintenance is essential. Dismantle the gas burner assembly, and clean and wash the burner and nozzles. The heat exchanger must be cleaned from the outside.
Panter Series 17. After ignition, the piezo igniter switches on again for a few seconds. It switches off regularly (1–2 times a day) due to an F1 error. Why is the appliance displaying this error? It is possible that the draught in the flue is significantly higher than the recommended 3–5 Pa. In this case, the pilot burner flame bends and the flame control electrode is at the edge of the pilot flame. When the flame flickers, a false signal indicating that the flame has gone out is sent, and the ignition unit shuts off the gas supply and initiates re-ignition. This is corrected by adjusting the position of the flame control electrode, with its tip bent slightly upwards. This is most likely the cause, because in the event of draught problems, ignition will not occur and the appliance will clearly display error F1. The gas boiler will not switch on due to error F83. An engineer I know connected a sensor directly, but the error persisted. What is happening? Error code F83 indicates that there is no heating medium in the system, as its temperature does not rise whilst the burner is running. The pressure drops below 0.3 bar. One reason for this is air in the heating system. It is also possible that the temperature sensors have failed, sending an incorrect signal to the control board. Why does the Panther 25 KTO boiler make a lot of noise when the burner is running at full power? What would you advise in this case? If the increased noise is related to the burner’s operation, it is likely caused by a faulty gas valve or bypass. Also, as the load increases, the gas meter may operate noisily. The heating system can also produce significant noise: air-conditioning ducts and radiators, or poorly installed shut-off valves. Within the unit itself, noise is often caused by a clogged heat exchanger, an unlubricated fan bearing, or a circulation pump operating at high pressure. Recently, a start-up problem has arisen. For some unknown reason, the main burner won’t ignite, but there’s a flame at the ignition device. I just can’t get my head round what might have happened. The ignition unit is probably faulty. We recommend that you check the unit and clean the ignition assembly. We use a Proterm Grizzly boiler at home. It had a problem about three days ago. It goes out as soon as the wind blows on the igniter. I’ve replaced the thermocouple twice, but it hasn’t helped at all. What could be the reason? When the main burner starts working, this causes a reduction in the gas supply to the ignition device, which means the control unit is triggered. You need to increase the fuel flow to the igniter. This may occur intermittently due to low pressure in the heating system. There may also be a lack of chimney draught if it has been designed incorrectly.
What is the problem if the Protherm Bear 40 KLZ boiler won’t start and displays error code F75? The pressure remains normal; there are no leaks. I’ve tried switching it off at the mains, but the fault persists. Can you tell me what the reason is? This situation usually occurs when the fluid pressure in the heating circuit is low. In this case, you need to check the pressure switch. The problem is likely to lie with it. This can occur intermittently as a result of low pressure in the heating system. There may also be a lack of chimney draught if the chimney has been designed incorrectly.
What is the problem if the Protherm Bear 40 KLZ boiler won’t start and displays error code F75? The pressure remains normal; there are no leaks. I’ve tried switching it off at the mains, but the fault persists. Can you tell me what the cause is? This situation usually occurs when the fluid pressure in the heating circuit is low. In this case, you need to check the pressure switch. The problem is likely to be with it.
Leopard 24 model. Why is error code F7 appearing? I’ve checked the sensors and the circuit board – there are no obvious faults. What could it be? Error F7 indicates a fault with the control board. This code signifies a communication fault between the display and the circuit board. Check the following: Try restarting the appliance. Check the circuit between the circuit board and the display for any breaks or short circuits. The live wire is reversed with the neutral; replace the plug. The pressure in the cooling system has fallen below the permitted minimum. Top up the system to 1–2 bar. The Proterm Cheetah gas boiler won’t switch on. The gas supply has been shut off for repairs. After the gas was turned back on, the appliance did not start automatically. I started it manually, and it works fine. Is this how it’s supposed to be? If no one is at home, could everything freeze up? How is this problem resolved? A restart usually occurs automatically following a power cut. In the event of a temporary lack of gas, the gas valve is activated because the appliance does not detect a flame and considers the gas pressure to be insufficient, but there is simply no gas in the system, as in your case.
Have a look at the manual on how to adjust the gas valve; it should tell you what to do to get the unit to restart itself. The gas valve may be faulty or not working properly. Still, the boiler has a reset button on the control panel (which lights up when there is no flame) and an emergency thermostat (a button in a recess under the cover). Try pressing it – this will reset the unit. The Panther KTO 25 single-circuit boiler is in operation with the boiler connected. The burner is burning continuously without switching off, whilst the display shows the set temperature of 54 degrees. Then the unit started to switch off completely, displaying error F29; after a restart (reset), it switches on and operates again without interruption. What could be the fault? Regarding error F29 – it seems the valve is stuck. The gas valve needs adjusting. It wouldn’t hurt to check the flue as well, as the boiler is atmospheric. If that doesn’t work, then most likely there was a spike in gas pressure and the gas valve failed. The solution to the problem is to replace the gas unit:
Proterm Lynx 23 BTVE. I switch it on, the fan starts, then the pump, then the gas valve clicks, the piezo ignition fires, then the gas ignites on the burner and goes out straight away. The piezo stops beeping immediately and the red indicator light flashes. I reversed the polarity on the stabiliser and tried running it without the stabiliser – nothing changed. I then cleaned the ignition and ionisation electrodes, the piezo, and pressed the button on the temperature sensor. Gas is being supplied, judging by the meter; the temperature in the room where the appliance is located is +15, whilst outside it is -3. Pressure is 1.5 bar. What is the fault? First, try cleaning the ignition and ionisation electrodes; the appliance should then work. Why does our boiler stop switching off once the desired temperature is reached? It heats up to 89 degrees, after which a fault occurs. After a restart, the situation occurs again. The control board is probably faulty, the temperature sensor is damaged, or the safety sensor button is faulty. It cannot be ruled out that the automatic controls have malfunctioned. In October of that year, I commissioned a Medved 20 PLO floor-standing boiler. After about five months, a problem arose. I’m trying to set the temperature cycle, but it won’t hold it. Please tell me, why isn’t the temperature holding? It seems the automatic control system has failed, and if the temperature rises to 62 degrees, the jets stop working. The automatic control system needs to be configured for it to function correctly. Another possible reason is that the selected boiler output is not suitable for the area to be heated.
Why hasn’t the Proterm TLO 30 boiler switched on? It also frequently displays error code F3. How can I fix this? This fault usually occurs as a result of problems with the thermostat or temperature sensor, or due to faults in the main circulation circuit. It appears that the fluid in the heat exchanger is overheating. If the temperature sensor and thermostat are working properly, the problem lies with the control board. You will need to replace it.
The Protherm 40 KLOM floor-standing dual-circuit boiler starts up briefly but then shuts down with error F1. It began operating following a recent power cut. How can this problem be resolved? In units of this model, error F1 is often associated with the thermostat overheating and can be resolved by restarting the unit using the STB button. It is also possible that the polarity in the mains supply has been reversed due to electrical work, which is critical for phase-dependent models. Another error indicates that the gas supply to the gas valve has been cut off due to a loss of flame. This loss is signalled by the ionisation electrode, which may have become blocked. In the worst-case scenario, the main board has failed due to a sudden surge in voltage, which occurs when the unit is connected to the mains without a stabiliser or UPS. The boiler is two years old. The first problem is that when the hot water is switched on, it does not switch off automatically; neither the heating circuit nor hot water is available until it switches off once the operating heating temperature is reached. The second problem is that the power cuts out regularly. The unit switches off, but always restarts automatically when the power is restored. The last time, it failed to restart and displayed error code F84. The pressure in the cooling system is 1.4 bar. I pressed the reset button and it started up straight away. What could be the problem? Error code F84 may indicate a constant temperature difference between the flow and return sensors (NTC2, NTC5). Cause: The temperature, flow and return sensor is reversed or disconnected. Faulty temperature sensor – Check the temperature sensor connector. Check the sensor (replace it if necessary). Regarding the activation of the heating circuit – it is possible that the settings give priority to the heating circuit – check this. Why does the Proterm Cheetah 23 gas boiler immediately display error F29 when switched on? I have removed the cover; the electrodes are clean and the phase-neutral connection is in place. Gas and water pressure are normal. I have dismantled the gas valve – it is clean; I tested the valve coil – it is working. When the appliance is switched on, there is no spark at the electrodes. What could be the cause? And when should the flue fan switch on? Error F29 – The flame goes out during operation and subsequent attempts to reignite it are unsuccessful. Interruption in the gas supply, incorrect earthing of the appliance. The gas valve needs to be dismantled and thoroughly cleaned. Most likely, the issue lies with the regulator that controls the gas supply. If microparticles get into it, it will not open. Clean it, even if it appears clean, and lubricate it – the boiler should then work. The fan should switch on and the unit will then ignite. Can anyone help sort out the problem with the chimney? The very next day, backdraught is observed, whilst the smoke immediately enters the kitchen. I built the chimney myself. It consists of a metal pipe. It seems there’s a fault somewhere. The main factor may be an incorrectly designed chimney. Sometimes the flue becomes contaminated with combustion products, which significantly reduces its efficiency. It’s also necessary to check the ventilation openings in the house. Please tell us how you can check the 3-way valve? I think this component isn’t opening properly. The radiators further away aren’t drawing heat for heating, and in DHW mode, the heating supply pipe beneath the boiler is getting hot. That’s correct; you need to check the 3-way valve for rust on its spindle in the intermediate position. On the other hand, we recommend that you have the heating system checked.
When the hot water tap is fully open, the unit starts to whistle and vibrate; when the water flow decreases, the noise subsides. What could this be? It usually indicates a clogged heat exchanger after prolonged use; the heat exchanger is failing. Over time, it becomes clogged with dirt and limescale. This causes such noises, and when the unit heats up, it releases air bubbles that hum and whistle – it definitely needs cleaning. Both heat exchangers should be flushed – the central heating and the DHW ones. After flushing, everything should work properly.
Proterm 40 klz. Summer. The DHW temperature is set to 50 degrees, but the unit overheats and displays an F3 error. The NTC sensor has been replaced. No improvement. What is the reason? The pump rotor has definitely failed. The pump has a plug – unscrew it; in the opening, you can see the end of the rotor with a screwdriver slot. Turn the rotor by hand using a screwdriver until it starts to turn freely. Start the unit. If the pump seizes up, this is due to overheating, and an error will then occur. You’ll need to remove the cover from the boiler. The reset button is located directly on the sensor housing, almost at the very top on the left-hand side. If everything is in order with the heating pump, you should check the condition of the heating filter and the domestic hot water heat exchanger. The reason is the same, namely blockage of the working components. And your symptoms – once it has cooled down, the fault resets itself. Very often, the electronics fail precisely because of unstable voltage or a sudden power cut. For many people, this problem disappeared after installing a voltage stabiliser. What causes the Proterm Jaguar boiler to display error F04? It switches on, then fails to switch on again. This has happened many times. It stops for a while, then the error light comes on again. Error F04 is resolved by replacing the DHW temperature sensor. This code indicates a problem with ionisation. We will need to repair the circuit board and check the optocoupler and other components. The unit runs for about two to three minutes, then the gas burner goes out and error F36 is displayed. It comes back on for about a minute, the gas burner reignites, and the appliance operates normally for another three to four minutes, and so on, many times. According to the manual, this fault indicates that the draught sensor has been triggered, but the flue is clear of blockages and the flue gases are being vented normally. Can’t work out what the problem is? In your case, the likely causes of the lack of draught are: a fault with the draught sensor. There is no contact between the control board and the draught sensor. Condensation, as well as an incorrect connection of the pipework to the pneumatic relay. A problem with the fan. It is most likely running at low speed.
The Protherm 30 TLO boiler was buzzing whilst switched on and is now rumbling even louder. Initially, the noise disappeared quickly, but now it can be heard for longer. Did this happen for a short time; have you observed such a problem? The excessive noise can be explained by the presence of limescale inside the heat exchanger casing, which does not heat up evenly due to variations in wall thickness. The more the heat exchanger is fouled, the louder the unit sounds and the more heat transfer decreases. I have this model installed. Today, when starting up, the pilot light ignites for a few seconds, the main burner fails to ignite, and the unit starts to shut down. How can this fault be rectified? The ignition mechanism is probably faulty, or there may be a problem with the burner. Just to be on the safe side, check that the phase sequence is not lost when connecting to the mains. The Proterm Medved 50 KLOM
gas boiler has been commissioned. Over the last week, error code F1 (ignition) has been flashing almost daily. After restarting it using the reset key, the unit occasionally starts up without any problems, but this is quite rare. Just yesterday, I removed the air vent and it started working better. What is the problem? If it starts showing a draught fault, it is essential to open the safety covers. This will help draw in air from the room. Then check the flue for ice and remove it if necessary. If the fault is related to combustion, you need to check whether there is a gas supply to the room.
A Jaguar JTV 24 wall-mounted dual-circuit boiler has been installed. Connected. The unit switches on, but after a minute displays error F01 and stops working. Bleed the air. No change. What is happening? When the water temperature in the heating system exceeds 98C, the unit switches off and, at the same time, indicators appear on the display showing that it is returning to its original state. Check the pressure in the system; the instructions for this model state that the unit will not operate at pressures above 2.5 bar. Perhaps this is the reason. The unit has determined that this limit has been reached and has therefore activated the protection mechanism. To reset the overheating protection, you therefore need to press the red button under the plastic cover – this should do the trick. We are using the same boiler. The unit immediately raises the temperature above 98 degrees, but then shuts down with an error. Later, once it has cooled down, it manages to switch itself on again. What is the reason? The overheating shutdown indicates a disruption in the circulation process. First, you need to check the radiator valves. They must remain open. Next, check whether the dirt filter is blocked, and you should also ensure that the heat exchanger is free of limescale.