Series and Parallel Battery Connections
![]()
When using independent power sources, situations often arise in which several cells connected in a particular way need to be used together. This requires some knowledge of how current flows in circuits with several power supplies. This article describes the nuances of different methods of connecting batteries into a combined battery pack.
Why Connect Batteries?
Some self-powered devices require current and voltage values that are difficult to provide using available standard galvanic power sources.

Typically, this means a need for a higher output current, increased voltage or greater capacity. To solve these problems, different configurations of connections between current sources must be created, each with its own characteristics.
Battery Connection Options
There are three schemes for connecting batteries into assemblies with the required parameters:
- Series – the voltages of all the batteries are added together;
- Parallel – the capacity adds up;
- Combined series-parallel – to increase both capacity and voltage.
All of them have particular features you need to know to ensure the safety and long-term operation of the batteries and the devices they power.
The main requirement for all connection methods is to avoid using batteries manufactured with different technologies in the same assembly (for example, Li-ion and Ni-Mh cannot be connected together).
Series Battery Connection
To ensure sufficient voltage and an acceptable operating time for electrical appliances, battery packs are often used in which the anodes and cathodes of the individual cells (sections) are connected in sequence by conductors.

The anode and cathode of the power sources at the ends of the resulting combined battery pack form its common positive and negative terminals. For a battery pack made from cells connected in series, the resulting voltage equals the sum of the voltages of the current sources used. The resulting capacity of the pack equals the capacity of the weakest connected battery. During operation of such an assembly, the same current flows through every cell, during both charging and discharging.
Connecting six batteries in series, each with a voltage of 1.2 volts and a capacity of 1200 mAh, produces an assembly of 6×1.2 = 7.2 V with a capacity of 1200 mAh.
If cells with different capacities are used in the assembly, those with a lower capacity will have a higher internal resistance than the others. The voltage drop across them will be greater, causing the weakest cell to discharge quickly during the process.
At the same time, the more powerful batteries in the assembly will continue to function and the assembly will keep operating. This will deeply discharge the weakest battery, reducing its service life and capacity.
When such an assembly is charged, the weakest battery is charged before the other cells. Because the others have not yet been charged, however, charging current continues to flow through it, causing overcharging and overheating. This is particularly dangerous for batteries containing lithium compounds because of their increased sensitivity to overcharging and deep discharge.
Important! Ultimately, constantly repeated deep discharge and charging of the weak cell in an assembly will quickly cause it to fail. Cells of the same capacity should therefore be used in a series connection. This can only be achieved by using power sources made by the same manufacturer, preferably from the same batch.
It is better to charge each power source in the assembled battery pack separately, or to use balancing charging with voltage control (current control) on each cell.
Parallel Battery Connection
In this case, all the anodes are connected by one common conductor and all the cathodes of the connected batteries by another. This circuit is used when the current from the assembled battery pack needs to be increased.

The total capacity (current supplied) of the resulting assembly equals the sum of the capacities (currents passing through) of the connected power sources. Its voltage will equal the voltage of the cell with the greatest electromotive force and will be the same across all the sources in the resulting battery pack.
Connecting six batteries in parallel, each with a voltage of 1.2 volts and a capacity of 1200 mAh, produces a 1.2 V assembly with a capacity of 6 x 1200 = 7200 mAh.
Warning! If several otherwise identical sources with different voltages are connected in parallel, current flows from the source with the higher voltage to the cell with the lower voltage.
This has a destructive effect on those with a lower capacity. Because of these current flows, connecting disposable batteries in parallel is prohibited: it charges the lower-voltage cells, causing them to overheat, leak electrolyte or explode.
If a high-voltage source with a low capacity is connected in parallel to a cell with a greater capacity but a lower voltage, the weak battery is electrically short-circuited through the lower internal resistance of the stronger battery. As a result, a large current flows in the weak source, gradually destroying it.
If the higher voltage is on the battery with the greater capacity, the weak cell is forcibly charged, which also has a harmful effect on it. For this reason, before assembling a battery pack, it is recommended to equalize the voltage of each of its cells to the same value.
Important! To eliminate the destructive effect of currents flowing between batteries connected in parallel, batteries with the same voltage must be used.
Series-Parallel Battery Connection
If you take account of the rules for connecting batteries into series and parallel assemblies, you can create complex combined configurations that use both methods at the same time. This allows you to increase the resulting capacity and voltage, which is particularly necessary in independent power supply systems, electric vehicles and other devices with high electrical current consumption.

A combined battery pack can be assembled in two ways:
- The required number of series-connected assemblies with the required voltage are assembled and then combined into a single battery pack using parallel connections.
- Battery packs are made from batteries connected in parallel to provide the required capacity, and these are then connected in series until the required voltage is reached.
Important! You need to understand that even if all connection rules are followed, it is impossible to select batteries with completely identical characteristics. This will inevitably lead to an imbalance in capacity and voltage values, which over time will cause increased wear on the weaker batteries.
Connection Precautions
Several safety precautions must be followed with all battery connection methods:
- Observe safety precautions when operating electrical equipment to prevent electric shock (the main thing is to avoid creating a current path through the human body):
- observe the connection polarity;
- do not create short circuits;
- disconnect the batteries when assembling them;
- connect the charger to the battery while the charger is disconnected from the mains;
- work should be carried out in suitable insulating clothing and footwear, without metal objects that could fall and short-circuit the contacts;
- do not touch battery contacts with your hands, especially with both hands on different poles (this is very dangerous with powerful high-voltage batteries);
- use a special tool with insulated parts;
- do not work when in poor health;
- allow for the currents flowing through the assembled battery pack and the load, and use conductors with a suitable cross-section;
- when connecting cells into a single battery pack, ensure a reliable contact that is insulated against external influences;
- ensure reliable protection of assembled battery packs against short circuits and moisture;
- use batteries with the same characteristics and degree of wear;
- carefully check the assembled battery pack for connection errors.

What Can Cause Battery Connection Errors? To eliminate errors when connecting batteries, it is recommended to use special connectors that prevent incorrect connections, such as T-Plug adapters. If batteries in the same assembly are connected incorrectly, faults can occur with very serious consequences:
- in a parallel connection, a short circuit is created, causing a violent chemical reaction in the batteries that very quickly leads to electrolyte leakage, deformation of the casing, fire or an explosion;
- if connected in series with the wrong polarity, the circuit is open, but when a load is connected, a reverse current may flow through the incorrectly connected cell and damage it;
- a prolonged short circuit in one or more batteries inevitably causes the insulation to ignite, conductors to melt, a violent reaction inside the battery, electrolyte leakage, deformation of the casing, fire or an explosion;
- after a brief short circuit across the contacts, the battery remains operational, but deterioration of the electrodes inside it may reduce its capacity;
- if conductors that are not designed for the operating currents are used, they overheat and their insulation melts, which can cause a short circuit and its resulting consequences.