Selena Gas Water Heaters – Common Signs of Faults and How to Fix Them
![]()
Contents
- The gas flame won't light
- Operation of the Selena geyser – Measures to rectify major faults
- Action algorithm (step-by-step instructions)
- Features relating to the use of the device
- The gas flame goes out
- Main causes of faults and how to rectify them
- Step-by-step guide with photos for repairing a gas water heater

Professional experts maintain that gas appliances are potentially dangerous, which is why they should be repaired and maintained by qualified technicians. You can identify which parts are faulty yourself, which will help to quickly restore the gas appliance to working order; some problems can easily be fixed by yourself.
Faults that do not affect the basic operation of a gas water heater can be rectified by DIY enthusiasts themselves. It is important to be familiar with the list and descriptions of the most common faults and to follow the manufacturer’s recommendations.

The gas flame won’t light
If a piece of technical equipment fails to start, there may be several reasons for this.

A faulty lighter. If the lighter is faulty, it will not light; in this case, you must contact the gas supplier. A qualified technician will replace the faulty part; it is not advisable to try to replace it yourself – this is genuinely dangerous.

The latest models are fitted with electronic ignition, which means that if ignition does not occur, the gas supply is cut off by a valve and the flow of blue fuel is stopped.
The instructions for repairing gas water heaters explain what to do; sometimes, simply replacing the battery is enough. If the instructions do not contain any recommendations, the only option is to contact the service department.


If there is no draught, the gas water heater will never ignite; check the draught by holding a strip of paper against the ventilation grille – simply bring the paper close to the grille. We’ve noticed that the position of the strip doesn’t change – there really are draught problems. In this case, repairing the gas water heater yourself involves cleaning the ventilation shafts.
A metal brush at the end of a long, flexible wire will help you do this yourself, but you shouldn’t expect public service staff to approve of such actions.


If the diaphragm in the mechanism is worn out, the burner will not work; this component will quickly become deformed, regardless of the cost of the appliance – after a maximum of 5 to 8 years.
To make sure that the membrane is faulty, turn the water pressure up to the maximum; a DIY enthusiast can replace the part themselves.


Operation of the Selena geyser – Measures to rectify major faults
The house has a Selena SWH 20 SE3 gas instantaneous water heater. Please explain why it has started to heat the water poorly. What advice can you give me to resolve this problem? The first problem is a blockage in the heat exchanger. Limescale build-up on the heat exchanger makes it difficult to heat the water as required, and the appliance begins to heat the water unsatisfactorily. For this reason, the heat exchanger must be cleaned. Secondly, the heat exchanger is regularly overheating. This indicates incorrect use of the appliance. The rise in temperature contributes to limescale build-up, which prevents the liquid from heating up. In this situation, it is recommended that the heat exchanger be replaced. At home, we use a gas water heater from the aforementioned company. After four years of operation, the heat exchanger began to leak. The repair did not solve the problem, and after three months I bought a new unit. The plumber said it should be cleaned and serviced every year. I cleaned it and carried out preventative maintenance. As a result, this unit lasted three and a half years, and the cause of the fault was the same – a leak in the heat exchanger. What could be the reason for this? It’s likely that the water quality is poor, which is why the heat exchangers are leaking. The same model is installed at my holiday cottage.
Please help me understand why the water sometimes overheats? What sort of fault is this? The problem is likely due to incorrectly installed controls. It is recommended to install them for the summer season. Use the gas knob to minimise the gas flow to the burner and then increase the water flow into the water heater. There has been a problem with the Selena Turbo gas flow regulator. The pilot light comes on; I keep it in this position for about 5 minutes. I then switch it to operating mode, but the appliance goes out.
What is causing this? We recommend removing the casing, disconnecting the gas supply pipe to the wick and cleaning it. Generally speaking, this should be done at least once a year, preferably at the end of summer, when dust enters the gas pipe through open windows.
Please help me understand what the problem is when the gas water heater sometimes does not heat properly. What should we do? It is possible that the burner flame is unstable, which indicates a fault with the diaphragm, and the spindle pressure on the gas valve is very weak. You’ll need to remove the water block from the gas appliance. Next, remove the cover from the water unit and check the diaphragm for deformation; if it’s unusable, replace the whole unit. A year ago, a gas water heater of this model was connected to heat a private house. Recently, a problem with ignition has arisen. When hot water is requested, the pilot light ignites. It lights up and then suddenly goes out, after which the water heater restarts. This happens 2–3 times.
After that, the unit returns to normal operation. Can you work out why the pilot flame isn’t igniting the main burner? What could be causing this? Today, the unit operates on this principle: a spark is generated which ignites the wick. Next, the spark supply stops; the igniter operates for a few seconds and then switches off. The appliance reignites, the wick starts to burn, the spark discharge disappears, and after a moment the main burner ignites. It seems that the ionisation sensor is faulty. You must check it first. Naturally, it is better to replace it with a new one, but if it fails, you will need to clean it with sandpaper. Clean the burner with a metal brush as well.
After taking these steps, don’t forget to check that the wick has a bluish flame, not a yellow one. Furthermore, the flame must reach the ionisation sensor. The Selena SWH
flow-through water heater was installed and commissioned a year ago. However, a problem is systematically observed in winter: a lack of gas, and furthermore, the gas is not clean. How can this problem be resolved? The adjustment screw is located at the bottom of the unit. With the burner switched on, try turning it anti-clockwise to set the correct flame height. When summer comes, you can turn it back. If this does not solve the problem, then the pressure in the system is indeed insufficient. We have been using the
gas water heater for about 6 years. Two days ago, the ignition system stopped working, and when I try to light it with matches, the flame can go out immediately as the regulator switches to the heating position. What should I do in this case? I’ve faced the same problem. The technicians explained that the thermocouple is faulty. Tell me about the fault with the gas water heater. When the hot water tap is turned on, the unit switches off. I tried cleaning the thermocouple, but it didn’t help. We checked the diaphragm; it’s fine, but we replaced it with a new one anyway. There is a drop in water pressure, although not a significant one. What is the problem? It is possible that the draught is insufficient or that the draught sensor is faulty. You should check this. Sometimes, instead of a draught sensor, there is a curved tube at the top of the appliance. This supplies the air needed for combustion. If the draught is disrupted, flue gases – rather than air – will begin to enter the tube. As a result, there will not be enough oxygen for the burner, and it will therefore go out. It is also necessary to check the burner flame. It must completely enclose the thermocouple. If this is not the case, the thermocouple will heat up slightly and will not send an ignition signal to the main burner.
Recently, I have started to notice a serious fault: the Selena column with the turbocharger stops during operation. Please explain what the problems might be? The water block diaphragm may be damaged. It may be deformed or worn, so it should be replaced. You can also check the EMC valve, as it contains an electromagnetic coil which may be faulty. The coil cannot be repaired, only replaced. Please explain the fault with the gas water heater. Shortly after switching on, the unit eventually goes out, and after that the ignition system can only be reignited using matches. What should I do? The draught in the flue has probably decreased, causing the back-draught sensor to activate and the water heater to switch off. You need to check the flue. The water in the heat exchanger may also overheat when the temperature rises to 90°C. In this case, the overheating sensor is triggered, which extinguishes the burner flame. To reduce the water temperature, you need to turn down the gas supply to the main burner using the regulator.
I’d like to know why the gas flame starts burning and then goes out? How would you advise resolving this fault? In the first instance, the cause is a blockage in the flue. It probably contains a large amount of soot, and the combustion products are not being fully removed, which triggers the draught sensor. This opens the thermocouple and the appliance’s flame goes out. Another reason is strong draughts, which can extinguish the appliance’s flame if there is a draught in the room. Consequently, the safety mechanism is triggered and cuts off the gas supply. Strong gusts of wind should be avoided. Nevertheless, you should not completely restrict the supply of fresh air, as the appliance must be operated with a window open. If there is no fresh air, the draught will be weak and the flame will start to go out. There is a Selena SWH 20 E2 gas water heater in a private house. Please explain why it has started to overheat the water? What are the recommended steps to rectify this fault? A possible cause is excessively high pressure. Set the regulator for the heating medium temperature to the highest flow rate, and set the gas regulator to the position for minimum gas flow to the burner. This method helps to reduce the temperature of the water coming out of the water heater. Why might ignition be delayed and the gas burner make a loud cracking sound? The flame from the ignition mechanism is not reaching the main burner or is too weak. You need to clean the nozzle and the igniter. Then carry out the adjustment. Fault with the gas water heater. I try to switch it on, it sparks, but it won’t ignite. How can you fix this? The pilot nozzle is blocked. You need to clean it. The ignition electrode is in the wrong position. Adjust it. There is air in the gas pipe. Bleed the air out. We have installed and connected a Selena instant water heater. The problem is that the appliance starts up and switches off after a few seconds. This happens mainly at night, when the appliance has been idle for a long time. Furthermore, if it is constantly heating water, it no longer switches off. Pressing and holding the microswitch for a long time causes the water heater to ignite and it works fine for several days. What is the reason for this? There’s no need to keep pressing the microswitch; simply fit a new one, as yours is faulty. The appliance’s operation is roughly as follows. First, a spark is generated and sent to the igniter. An ionisation signal is transmitted, gas flows to the main burner and a flame appears. If there is no signal indicating that the pilot burner is working, the main burner will not ignite either. Your ignition unit sends a signal even though the main burner does not ignite.
Ignition has started, but there is no signal, so the gas flow stops. Try cleaning the electrode. A similar unit is being used. What causes the ignition device to go out at the moment of ignition? What might be the problem? The thermocouple is faulty. It needs replacing. The coil is faulty. Fit a new one. There was a query regarding the operation of the Selena water heater. The situation is as follows: the pilot burner ignites, but the main burner does not work. What should I do and how can I fix it? The water pressure has dropped. Set the required pressure in the system. To do this, we recommend turning the switch fully to the right. The diaphragm is worn out. Replace it. I am using a column in a private house. If you stop the water flow, the burner does not go out. What is the cause of the fault?
The gas valve flap is blocked. Check it. Flush it out if necessary. The water valve stem is difficult to move when opening. Dismantle the components, clean them and, if necessary, fit new ones. Check the inlet gas pressure. Adjust if necessary. Replace the pressure regulator in the cylinder. I just don’t understand why there is no spark when the appliance is switched on? The ignition wires have become disconnected. Reconnect the wires as required. Ignition element fault. This component needs to be checked and replaced. Broken ignition electrode. A replacement is required. We recommend turning the switch fully to the right. Worn diaphragm. Replace it. I’m using the unit in a private house. If you stop the water flow, the burner does not go out. What is the cause of the fault? The gas valve flap is blocked. Check it. Flush it out if necessary. The water valve stem is difficult to move when opening. Dismantle the components, clean them, and fit new ones if necessary. Check the inlet gas pressure. Adjust it if necessary. Replace the pressure regulator in the cylinder. I just don’t understand why there is no spark when the appliance is switched on? The ignition wires have become disconnected. Reconnect the wires as required. Fault with the ignition element. This component needs to be checked and replaced. Broken ignition electrode. A replacement is required. We recommend turning the switch fully to the right. Diaphragm worn out. Replace it. I’m using the unit in a private house. If you stop the water flow, the burner does not go out. What is the cause of the fault? The gas valve flap is blocked. Check it. Flush it out if necessary. The water valve stem is difficult to move when opening. Dismantle the components, clean them, and fit new ones if necessary. Check the inlet gas pressure. Adjust it if necessary. Replace the pressure regulator in the cylinder. I just don’t understand why there is no spark when the appliance is switched on? The ignition wires have become disconnected. Reconnect the wires as required. Faulty ignition element. This component needs to be checked and replaced. Broken ignition electrode. A replacement is required. If you stop the water flow, the burner does not go out. What is the cause of the fault? The gas valve flap is blocked. Check it. Flush it if necessary. The water valve stem is difficult to move when opening. Dismantle the components, clean them and, if necessary, fit new ones. Check the inlet gas pressure. Adjust it if necessary. Replace the pressure regulator in the cylinder. I just don’t understand why there is no spark when the appliance is switched on? The ignition wires have become disconnected. Reconnect the wires as required. Faulty ignition element. This component needs to be checked and replaced. Broken ignition electrode. A replacement is required. If you stop the water flow, the burner does not go out. What is the cause of the fault? The gas valve flap is blocked. Check it. Flush it if necessary. The water valve stem is difficult to move when opening. Dismantle the components, clean them, and install new ones if necessary. Check the inlet gas pressure. Adjust it if necessary. Replace the pressure-reducing valve in the cylinder. I just don’t understand why there is no spark when the appliance is started? The ignition wires have become disconnected. Reconnect the wires as required. Faulty ignition element. This component needs to be checked and replaced. Broken ignition electrode. A replacement is required. The water valve stem is difficult to move when opening. Dismantle the components, clean them and, if necessary, fit new ones. Check the inlet gas pressure. Adjust if necessary. Replace the pressure regulator in the cylinder. I just don’t understand why there is no spark when the appliance is started? The ignition wires have been disconnected. Reconnect the wires as required. Fault with the ignition element. This component needs to be checked and replaced. Broken ignition electrode. A replacement is required. The water valve stem is difficult to move when opening. Dismantle the components, clean them and, if necessary, fit new ones. Check the inlet gas pressure. Adjust if necessary. Replace the pressure regulator in the cylinder. I just don’t understand why there is no spark when the appliance is started? The ignition wires have been disconnected. Reconnect the wires as required. Ignition element fault. This component needs to be checked and replaced. Broken ignition electrode. A replacement is required. This unit needs to be checked and replaced. Broken ignition electrode. A replacement is required. This unit needs to be checked and replaced. Broken ignition electrode. A replacement is required. This unit needs to be checked and replaced. Broken ignition electrode. A replacement is required.
- Gas boilers
- Electric boilers
- Gas water heaters
- Faults and repairs to gas water heaters
- Water heaters
- Boiler error codes
- Troubleshooting boiler faults
- Troubleshooting water heaters
- Repair of indirect heating boilers
- Troubleshooting electric convector heaters
- BOSCH THERM 4000
Models WR-13, WR-13. Technical specifications. Installation. Maintenance and modifications.
- NEVA 4510
Design and main components. Installation and connections.
- NEVA 4511
The purpose of the main components and parts. Maintenance and replacement of parts.
- NEVA 4513
Adjustments and settings. Servicing.
- NEVA
Design features. Faults and maintenance.
- NEVA LUX 5514
Elements and components. Installation and assembly. Operation and modifications.
- NEVA REPAIR
The Neva VPG-12E gas water heater is in operation; when the hot water tap is turned on, the indicator light comes on, but the temperature does not rise above 20 degrees. The water pressure is normal; it does not respond to the flame booster control – once it reaches 18–20 degrees, it stays there. What could be the problem?
- ARISTON
I’ve connected the Ariston Marco Polo Gi7s water heater. Everything’s working. But the unit has switched on for the second time. That is to say, when you turn on the water, the water heater starts up, clicks, and then displays error E1. I then turned the tap off, turned it back on, and it started up again. It’s gas-fired. Is this possible because I turn off the gas after it has finished working?
- ELECTROLUX
My Electrolux 275 gas hob is playing up. When I turn on the hot water, all the lights come on and it works for 5–7 minutes, then there’s a click and it switches off, along with the igniter. Can you tell me what the problem is?
- OASIS
Fault with the Oasis TUR 20 gas water heater. In ‘Summer’ mode, the gas and water controls are set to maximum. It switches itself off after 5 minutes, and again after 30 minutes. In ‘Winter’ mode, regardless of the combination of controls, it switches off after 30–40 seconds. What could be wrong? The water supply is via flexible hoses. Could they be the cause? If so, what should I replace them with?
- VEKTOR
Tell me, I’ve got this problem: when the water’s turned off, the light comes on by itself, the temperature rises and it won’t switch off (I had to take the batteries out); I put the batteries back in (without turning the water on), and it comes on again – what should I do?
- ASTER
Please help me find the reason why my Astra 8910-02 gas water heater switches off from time to time when the hot water is on. I’ve cleaned the thermocouple until it’s sparkling clean, the diaphragm is in good condition, but just in case I replace it with a new one, the water pressure is lower than when the cold water is on. Any other suggestions?
- BOSCH
I installed and commissioned a Bosch WR 13 gas water heater. I switched the nozzles to LPG, removed the jumper from J6 – in other words, I switched to LPG mode – but the water heater isn’t working. Does anyone know what to do about this? When switched on, the green button lights up for a few seconds, then the red one starts flashing and only the fan comes on.
- JUNKERS
My Junkers gas water heater has started playing up. It runs for 15–20 minutes and then switches off. If you turn the water off and on again, the pilot light comes on but goes out after a few seconds; you can do this as many times as you like, but it won’t stay lit. After a short while, it works again, only for the whole process to repeat itself. The water pressure is fine, as is the gas pressure. What could be the reason?
Action algorithm (step-by-step instructions)

Unscrew the fasteners from the water unit.
To access the rubber diaphragm, you will need to remove half of the assembly; if the component is severely deformed, then this is the main cause of the problem. You can buy the part from a shop that sells spare parts for gas water heaters, but it is better to choose a silicone diaphragm, as it is more durable than a rubber one.


Check the condition of the filter on the water inlet; it must be cleaned whenever it becomes blocked. To clean the filter, unscrew the nut, remove the mesh and rinse it; if it is damaged, the filter element must be replaced.
Features relating to the use of the device
Therefore, to ensure that the Oasis gas water heater – the user manual for which is supplied with the product – operates efficiently, you must follow certain guidelines when using the appliance:
- Use only the type of gas specified in the technical recommendations;
- It is necessary to monitor the charge level of the batteries powering the device;
- To switch off the appliance, you must first turn off the water;
- If you are using the appliance for the first time, you must bear in mind that there may be air in the gas supply pipes, so the appliance may not ignite straight away;
- The water heating setting must be adjusted by turning the tap handle or the gas control knob on the body of the appliance;
- If you are going to switch off the appliance for an extended period, you must first turn off the hot water tap and the gas valve.
The gas flame goes out
When a domestic heater switches on for the first time but soon switches off again, the cause is often a fault in the bimetallic temperature sensor, which is needed to protect the appliance from overheating. If the temperature sensor is faulty, the appliance may fail to switch on, and the following scenarios may occur:

The gas burner ignites, the appliance switches on and works properly for a while, but then quickly goes out, after which it is no longer possible to reignite the heater. It takes 20 or 30 minutes before the appliance can be switched on again, but then the same thing happens.
If the sensor is too sensitive, this is a manufacturing fault. It is better to call a technician and have the device repaired under warranty than to struggle to get it working.


The appliance switches off randomly and sometimes fails to switch on. The insulation on the wire has worn away, causing a short circuit in the body; this triggers the safety valve, and the water heater stops working normally. In this case, the staff at the service centre will be able to help you.
Main causes of faults and how to rectify them
The designs of all gas water heaters are similar. Why not summarise all the problems and describe possible solutions? Because every brand has its own weaknesses. Then there are faults specific to particular brands. We have analysed user reviews to provide you with reliable information.
Manufacturing defects are extremely rare in Oasis water heaters.
External and internal factors can cause a malfunction:
- Incorrect installation and connection.
- Incorrect operation.
- Blockages in the flue and ventilation system.
- Problems with internal components: limescale, corrosion.
Below, we have outlined ways to resolve these issues.
The column is not lit
There could be many reasons; we’ll help you figure it out. The main thing is to pinpoint the fault correctly.
If the device does not ignite at all and no spark is produced, then:
- The batteries are flat. Automatic ignition devices are powered by the battery. When replacing them, use high-quality batteries with a good charge. If you find that they have leaked where they were installed, clean all the contacts and fit new batteries.
- Traction problems. For the appliance to operate normally, there must be a draught in the flue. If there isn’t, check the vent to see if it is blocked. This may be due to a foreign object, soot or dirt from outside. If possible, clear the vent. Ensure that the outside of the chimney outlet is not blocked.
How can you tell if there’s a draught? Light a match and hold it up to the vent in the flue. If the flame wavers, there’s a draught; if it burns steadily, there isn’t. You can also hold a piece of paper against the vent to check for draughts. If there is a draught, the sheet of paper will press against the terminal; otherwise, it will fall down.
- The water pressure regulator is set to the minimum level. A small amount of pressure is built up in the system to activate the diaphragm and open the gas valve. Turn the knob to the maximum setting.
- Low water pressure in the pipes. Does a trickle of water come out when you turn on the tap? Contact your water supplier and wait for the supply to be restored. If this happens frequently, it is advisable to install a circulation pump.
- The filter is blocked. Part of it is located at the inlet to the water unit and traps small particles of dirt carried in by the water flow. You will need to take the unit apart and rinse the filter under running water.
- The diaphragm is stretched. The component is used to operate the gas valve. When pressure builds up in the pipe, the diaphragm expands, pushes the stem and opens the valve. Over time, it wears out and needs replacing. You can read more about this here: ‘Water column of a gas column’.
- The microswitch is broken. It cannot be repaired, so it needs to be replaced.
- Problems with the electrical wiring. Remove the cover and check all the wires leading to the control box. If the insulation is damaged, replace the cable.
- Faulty solenoid valve in the gas unit. You must check it, inspect it and fit a new part.
The flame flares up and goes out
This happens when the electronic control unit does not receive an ignition signal; it then stops the ignition and cuts off the gas supply. This may be caused by a fault in the flame sensor or the build-up of carbon deposits on the sensor.
Solution: Gently clean the sensor with a fine-grit sandpaper (grade 0). In this case, you should not be too vigorous, so as not to damage the metal coating. If this procedure fails, the flame sensor must be replaced.
The column is leaking
A leak is a serious problem, but you can sort it out yourself.
The seal is leaking through the shaft. To check this, remove the cover and see where the water is coming from.
How to carry out a DIY repair:
- Remove the adjustment knobs by pulling them towards you.
- Unscrew the four screws securing the cover.
- Disconnect the display cables.
- Remove the batteries from the unit and detach it by unscrewing the screw at the bottom.
- Disconnect the water hoses.
- Unscrew the screws on the water valve and remove it.
- You have now reached the flush valve and its stem. When removing the old valve body, the seal may remain inside – this is not a major problem. Simply remove the seal from the new part and fit it.
- Assembly is carried out upside down.
A more serious problem is a leak in the radiator. A new heat exchanger costs almost as much as a new Oasis Turbo model. How can you save money? Seal the leaks by soldering them. Read more in the article ‘How to solder a gas water heater’.
The simplest way to repair a leak is if a hole has formed on the outside of the tube. In this case, you can use cold welding. Internal corrosion requires the use of a soldering iron or a blowtorch set to 170 degrees. A rosin or aspirin tablet works well as a flux.
Before you start work, prepare the radiator:
- Drain the pipe.
- Dry.
- Sand the soldering area with fine-grit sandpaper.
- Wipe with a degreaser.
You can start the repair. To prevent a fistula from forming, the solder should be 2–3 mm thick. Check the joint for green spots – these are potential fistulas. It is best to deal with them straight away.
The lights go out after a few minutes
This sort of fault is often linked to poor traction or overheating.
Solution: clean the flue; reduce the water temperature by adjusting the flame and pressure; do not dilute the hot water with the mixer tap.
A clogged heat exchanger
How to tell if a radiator is blocked:
- Long-term water heating.
- The stream isn’t hot, but it’s warm.
- Pieces of limescale come out along with the water.
A smell of gas can be detected whilst the heater is in operation

If you switch on the hob and notice a sharp, unpleasant smell of gas, switch off the appliance immediately, turn off the gas supply at the valve, ventilate the room and call the gas company.

Taking any action on your own is dangerous; you do not have the necessary qualifications.
The petrol gauge lights up and goes out
Gas water heater – this appliance is quite reliable and, if operated and maintained correctly, will last a long time. However, sooner or later everything breaks down and needs repairing. Faults in gas appliances should be entrusted to the reliable hands of professionals. Today, however, we’ll look at typical examples of faults that aren’t related to a malfunction of the appliance itself, and learn how to identify a particular fault even before the specialists arrive. The first reason why the flame might go out when lighting a gas hob could be a lack of draught in the ventilation duct.

A situation where the gas light doesn’t come on is, of course, a nuisance, but it’s too early to panic.
Step-by-step guide with photos for repairing a gas water heater