PROTHERM Boiler Fault Codes: Some Problems You May Be Able to Resolve Yourself
![]()
Contents
- PROTHERM FAULT F.0 (F.00)
- PROTHERM FAULT F.01 (F.1)
- PROTHERM FAULT F.10
- PROTHERM FAULT F.11
- PROTHERM FAULT F.20
- PROTHERM FAULT F.22
- PROTHERM FAULT F.23
- PROTHERM FAULT F.24
- PROTHERM FAULT F.25
- PROTHERM FAULT F.26
- PROTHERM FAULT F.27
- PROTHERM FAULT F.28
- PROTHERM FAULT F0, FO
- PROTHERM FAULT F1
- PROTHERM FAULT F2
- PROTHERM FAULT F3
- PROTHERM FAULT F4
- PROTHERM FAULT F5
- PROTHERM FAULT F6
- PROTHERM FAULT F7
- PROTHERM FAULT F9
PROTHERM FAULT F.0 (F.00)
Protherm fault F0 (F00)
- Open circuit — NTC sensor at the heating water outlet
Resolving Fault F 00 on a Protherm Boiler
- Check the boiler wiring
- Check the boiler outlet sensor
- Call a Protherm service technician
PROTHERM FAULT F.01 (F.1)
Protherm fault F01 (F1)
- Open circuit — NTC sensor on the heating water return
Resolving Fault F 01 on a Protherm Boiler
- Check the boiler wiring
- Check the sensor on the return to the boiler
- Call a Protherm service technician
PROTHERM FAULT F.10
Protherm fault F10
- Short circuit — heating water outlet NTC sensor (<130 °C)
Resolving Fault F 10 on a Protherm Boiler
- Check the boiler wiring
- Check the boiler outlet sensor
- Call a Protherm service technician
PROTHERM FAULT F.11
Protherm fault F11
- Short circuit — heating water return NTC sensor (<130 °C)
Resolving Fault F 11 on a Protherm Boiler
- Check the boiler wiring
- Check the sensor on the return to the boiler
- Call a Protherm service technician
PROTHERM FAULT F.20
Protherm fault F20
- The safety temperature limiter has switched off
- Maximum T1 or T2 temperature exceeded
Resolving Fault F 20 on a Protherm Boiler
- Check the sensor wiring
- Check the sensors at the boiler outlet and inlet
- Check the pump
- Check heating water pressure, at least 1 bar, and check for air in the boiler
- Call a Protherm service technician
PROTHERM FAULT F.22
Protherm fault F22
- Insufficient water in the heating system
Resolving Fault F 22 on a Protherm Boiler
- Check heating water pressure; approximately 1.2 bar is sufficient for most boilers
- Boilers with instantaneous hot water heating have an integrated heating-system filling tap
- Bleed the heating system
- Restart the boiler using the Reset button
- Call a Protherm service technician
PROTHERM FAULT F.23
Protherm fault F23
- Insufficient water in the heating system
- Too little heating water in the boiler
- The circulation pump is not working
- The difference between outlet and inlet is too large
Resolving Fault F 23 on a Protherm Boiler
- Check heating-system pressure and top up to 1.2 bar if necessary
- Bleed the radiators
- Check that the circulation pump works
- Call a Protherm service technician
PROTHERM FAULT F.24
Protherm fault F24
- Insufficient water in the heating system
- Temperature rising too quickly
- Too little heating water in the boiler
- The circulation pump is not working
Resolving Fault F 24 on a Protherm Boiler
- Check heating-system pressure and top up to 1.2 bar if necessary
- Bleed the radiators
- Check that the circulation pump works
- Check whether the pump output is set too low
- Check that the return-line strainer is clean
- Call a Protherm service technician
PROTHERM FAULT F.25
Protherm fault F25
- Safety shutdown due to flue gases
- The flue thermostat detected unwanted escape of flue gases outside the flue system.
Resolving Fault F 25 on a Protherm Boiler
- Check that the chimney works and contains no obstruction preventing proper draught.
- Check the air supply to the boiler!!!
- The whole boiler must be checked, including heat exchanger cleanliness and gas valve settings…
- Call a Protherm service technician
A Protherm service technician must absolutely inspect the boiler. Flue gases escaping into the room can cause serious health problems and, in most cases, death of people in the home!!!

PROTHERM FAULT F.26
Protherm fault F26
- Gas valve assembly fault
Resolving Fault F 26 on a Protherm Boiler
- Gas valve stepper motor fault.
- RESET the boiler. If the error recurs, the gas valve must be replaced.
- Call a Protherm service technician
PROTHERM FAULT F.27
Protherm fault F27
- The ionisation signal reports a flame even though the gas valve is off
- So-called extraneous light
Resolving Fault F 27 on a Protherm Boiler
- The gas valve may be faulty
- Flame monitoring malfunction; the electronics will probably need replacement
- Check the boiler power supply and remove any splitter adapter in the supply path
- Restart the boiler using the Reset button
- Call a Protherm service technician
PROTHERM FAULT F.28
Protherm fault F28
- The boiler cannot ignite a flame
- The boiler did not ignite within the safety time
Resolving Fault F 28 on a Protherm Boiler
- Check that gas reaches the boiler, for example by testing the cooker flame
- Physically check whether your gas meter is installed!!
- Check whether the boiler is plugged in through a splitter adapter; remove it if so
- Check that the condensate trap is clear on condensing boilers
- Possible fault in the ignition or ionisation electrode, gas valve or similar components
- Restart the boiler using the Reset button
- Call a Protherm service technician
PROTHERM FAULT F0, FO
Protherm fault F.0 (FO)
- No heating water flow through the boiler
Resolving Fault F 0 (FO) on a Protherm Boiler
- Check the boiler and heating system for trapped air; bleed if necessary
- Check whether the pump rotates; if necessary, free it using a flat-head screwdriver
- Check the return-line strainer and open all radiators to setting 5
- Call a Protherm service technician.
PROTHERM FAULT F1
Protherm fault F.1
- No-flame indication
- The boiler did not ignite within the safety time
Resolving Fault F 1 on a Protherm Boiler
- Check that gas reaches the boiler, for example by testing the cooker flame
- Check whether the boiler is connected through a splitter adapter; plug it directly into the socket
- Check that the boiler trap is clear and inspect the ignition and ionisation electrodes, gas valve and similar components
- Call a Protherm service technician.
PROTHERM FAULT F2
Protherm fault F.2
- Indicates a heating water sensor fault or heating water temperature below 3 °C.
- The boiler switches off and cannot be restarted
Resolving Fault F 2 on a Protherm Boiler
- Check the ambient temperature around the boiler
- The NTC sensor will probably need replacement
- Call a Protherm service technician.
PROTHERM FAULT F3
Protherm fault F.3
- Indicates heating water temperature above 95 °C.
- The boiler switches off and resumes automatically once the water cools.
Resolving Fault F 3 on a Protherm Boiler
- Check the boiler and heating system for trapped air; bleed if necessary
- Check whether the pump rotates; if necessary, free it using a flat-head screwdriver
- Check the return-line strainer and open all radiators to setting 5
- The NTC sensor may be faulty and will probably need replacement
- Call a Protherm service technician.
PROTHERM FAULT F4
Protherm fault F.4
- Indicates a DHW sensor fault.
- DHW cylinder heating stops, but space-heating mode is unaffected.
Resolving Fault F 4 on a Protherm Boiler
- Check the sensor inserted into the hot water cylinder, including whether there is water in the tank…
- The hot water sensor is probably faulty
- Call a Protherm service technician.
PROTHERM FAULT F5
Protherm fault F.5
- The flame continues for more than 5 seconds after the gas valve closes (TIGER v.17)
- Supply voltage below 170 V (TIGER v.17)
- An incompatible control board or user-interface display board is installed, on v.17 models
- Outdoor sensor fault, or weather-compensation parameters are set without an outdoor sensor connected
Resolving Fault F 5 on a Protherm Boiler
- Check whether heating-curve parameters E, P and U are set; set E-, P- and U-
- If using weather compensation, check the outdoor sensor
- Call a Protherm service technician.
PROTHERM FAULT F6
Protherm fault F.6
- The air pressure switch (KTZ, KTO, KTV) remains open
- The flue thermostat (KOZ, KTO, KTV) is open — flue gases leaking into the boiler room!!!!!
Resolving Fault F 6 on a Protherm Boiler
- Check the flue route; have a chimney sweep inspect it!!
- Check combustion air supply for chimney-connected type B boilers!!!
- The whole boiler must be checked, including heat exchanger cleanliness and gas valve settings…
- Call a Protherm service technician
For atmospheric, type B boilers with flue discharge into a chimney, inspection by a Protherm service technician is absolutely essential. Flue gases escaping into the room can cause serious health problems and, in most cases, death of people in the home!!!
PROTHERM FAULT F7
Protherm fault F.7
- Communication error
Resolving Fault F 3 on a Protherm Boiler
- Call a Protherm service technician.
PROTHERM FAULT F9
Protherm fault F.9
- Some boiler parameters may have lost their user or service settings.
Resolving Fault F 9 on a Protherm Boiler
- Call a Protherm service technician.