Heating pipes: a brief overview of materials and types of electrical installation
![]()
Contents
- Choosing a heating system
- Types of heating in a private house
- Calculating the volume of coolant
- Calculation of a house’s heating system
- Circulation of the heating medium
- Filling and commissioning a closed heating system
- Methods of laying heating pipes
- Basic rules for installing heating pipes
- Advantages and disadvantages of corrugated steel pipes for heating
- Collector heating circuit (beam, fan).
- Requirements
- Two-pipe system
- Methods of connecting radiators
- Single-tube circuit (“Leningrad”)
- Materials used in heating pipes
- Plastic heating pipes, PVC and flexible polymer pipes
- Heating equipment
- Registers
- Choosing a heating system layout
- Other components of the heating system
- Tips for connecting batteries in a diagonal configuration
- Heat carrier
- How is the coolant replaced in the heating systems of various types of heating systems?
- Preparatory work
- Radiator wiring diagrams
Heating is the most important aspect of building services, without which it is impossible to live comfortably in a holiday cottage. The heating system in a private house must be installed correctly, and that is quite an art. To avoid making mistakes, it is necessary to be aware of many subtleties and nuances. Such knowledge can only be gained through a combination of theory and practical experience.
Nedeštruktívne
Technoogie
ktoré nikde nekúpiš.
If you have any questions about organising the heating system for your private home and would like to consult an engineer, please call or email us. Our specialists will be happy to answer your questions and explain any details you are interested in.
Choosing a heating system
Choosing a heating system for a holiday home is no simple matter. There are many pros and cons to weigh up. In this case, the following factors need to be considered and analysed:
- Fuel availability
- Reliability – the technologies used must be tried and tested
- The costs of both the heating system itself and its operation and maintenance
- The prevalence of the technologies on which a house’s heating system is based, and the availability of specialists for regular maintenance
- Sustainability
- Appearance and design compatibility
- Individual requirements and their feasibility without compromising the overall quality of the heating system
We have also tried to highlight the key points, which, once understood, will help you make an informed choice. If you have any questions, you are always welcome to contact us and ask for advice.
Types of heating in a private house
All heating systems can be classified according to the following parameters:
By fuel type
Depending on the type of fuel used, the following types of heating systems may be installed in private country homes:
- Gas (natural gas or liquefied gas)
- Electric
- Solid fuel (firewood, sawdust, pellets, coal, etc.)
- Liquid fuel (diesel, waste oil, etc.)
- Geothermal – systems based on renewable (alternative) energy sources
They all have their pros and cons. Natural gas is the best fuel for Moscow and the Moscow Region. If your country house can be connected to the gas mains, you should choose this option without hesitation.
By type of coolant
Depending on the type of coolant used in the heating circuit, a house’s heating system may fall into one of the following categories:
- Water
- Air
- Steam
- Combined – combining several types of coolant
In Moscow and the Moscow Region, the most common type of heating involves the use of water-heating systems. We will look at these in more detail.
Calculating the volume of coolant
Residents of blocks of flats may not be aware of the volume of coolant in the system, but in detached houses this information is very important:
1. Firstly, the expansion tank is selected based on the capacity of the heating system. Whilst exceeding the required size will not cause any particular problems, a tank that is too small will lead to constant overflow of the coolant and will need to be topped up regularly.

2. Secondly, it is very difficult to maintain a stable temperature for heating in rural homes, and this is impossible when using solid-fuel boilers. During a cold spell, it is not possible to leave the heating system filled with water, so the only solution to the problem is to use antifreeze. As the cost of antifreeze depends directly on the volume of coolant required, it is necessary to know the volume of the system.
There are two ways to determine the capacity of a heating system without resorting to complex calculation methods or regulatory documents:
1. The first method is possible if, before filling the closed heating system, a connection is made to the water supply via a bypass. The completely drained circuit (free of coolant and air) is filled with water whilst the taps and valves are closed. The amount of water used to fill the heating system can be determined using a meter fitted to the water supply system.
2. The second method involves flushing the system via the relevant valve and placing a container of known volume under the running water. When measuring the volume of coolant in this way, it is necessary to open the vent valves on each heating unit to ensure that no water remains in them, which could lead to measurement errors.
Calculation of a house’s heating system

To be absolutely sure that your holiday home’s heating system will work properly, you need to draw up a design. However, if the holiday home is small, you can do without a design. In this case, you need to carry out an engineering calculation of heat loss.
The essence of the calculation boils down to determining the required heat output. This characterises the amount of heat that needs to be supplied to each heated room in the cottage. The required heat output corresponds to the heat losses. Heat losses – the amount of heat that escapes from a country house through its building envelope (thermal envelope).
Heat loss calculations are carried out for each individual room and for the cottage as a whole. Based on these calculations, a boiler is selected, along with radiators or other heating appliances.
There is a simplified method that allows you to calculate the approximate heat output required for each room in a country house. To do this, multiply the room’s floor area by 100–130 W (depending on the number of external walls). However, this method provides approximate results that do not take a number of factors into account.
There are special formulae for making an accurate calculation. First, the thermal resistance R (in m² * °C / W) is determined. It is equal to the ratio of the thickness of the protective structures (in metres) to their thermal conductivity. This is a table value.
| Material | Thickness | R |
| Brick | 0.8 m | 0.6 |
| 0.7 m | 0.5 | |
| 0.6 m | 0.4 | |
| 0.3 m | 0.2 | |
| Log | 0.3 m | 0.6 |
| 0.2 m | 0.5 | |
| Beams | 0.2 m | 0.8 |
| 0.1 m | 0.4 | |
| Insulated frame | 0.2 m | 0.7 |
| Foam concrete | 0.3 m | 0.7 |
| 0.2 m | 0.5 | |
| Plaster | 0.03 | 0.04 |
| Ceiling or loft | 1.4 | |
| Wooden floor | 1.9 | |
| Wooden double doors | 0.2 |
A formula is then used to calculate the amount of heat loss (in watts) occurring in the heating circuit:
Q = S * (Tvn – Tnar) / R
S – the area of the heated room,
Tvn – desired room temperature,
Tнр is the minimum outdoor temperature during the coldest period of the year.
Heat energy is also lost through ventilation (both natural and forced). The amount of heat lost is calculated using the following formula:
Q = c * m * (Tvn – Tnar)
m is the mass of the air in the rooms (the product of the total volume of the rooms and the density of air); c is its heat capacity, which is 0.28 W/kg·°C.
To calculate the required total heat output, it is necessary to add up the heat losses through the walls, floor, roof and ventilation. The resulting total is multiplied by a factor of 1.3.
In addition to the thermal calculation, a hydraulic calculation can also be carried out. This serves as the basis for selecting pipe diameters and the parameters of the pump units. This calculation forms part of the heating design.
Circulation of the heating medium
Depending on how the coolant flows through the pipework, a house’s heating system can be designed in two ways:
Option with forced circulation of the coolant

For a forced-circulation heating system in a private house, a circulation pump must be installed in the heating system. It ensures that the heated fluid flows through the pipes to the radiators. In this case, there is no need for a pipe gradient. When radiators are installed in the system, Mayevsky valves must be fitted to them to bleed air locks. The cooled heat transfer fluid is returned to the boiler room via the return loop.
The advantages of the forced-circulation coolant option are:
- High flow rate of the coolant. As a result, the fluid in the return loop is hardly cooled at all. This allows you to optimise the use of fuel or electricity (depending on the type of boiler)
- The ability to set the temperature settings for each heating appliance
- Minimising the internal cross-sectional area of the pipework without reducing the flow resistance within the pipework
Version with natural circulation of the heating medium

Other names used for this system, which is based on this principle, include ‘gravity-fed’ and ‘convection-based’. Heating a private house using natural circulation of the coolant – a cost-effective option
The principle of operation is as follows. As water is heated, its density decreases. Consequently, the hot water in the supply circuit is pushed upwards by the heavier, cooled water in the return circuit.
To prevent water hammer caused by an increase in volume (and consequently in the pressure of the coolant within the system), an expansion tank is fitted at the top of the system. As a result, more heated fluid enters the radiators, whilst the cooled coolant returns to the boiler via the return circuit.
In this heating system for a private cottage, the principle of gravity operates alongside the principle of convection. To this end, a slight gradient is created in the supply circuit from the riser to the heating units, thereby increasing the flow of the coolant by gravity. Accordingly, the return circuit is sloped towards the boiler.
This method has several advantages:
- Low price
- No circulation pump requiring a power supply is needed. This allows for a heating system that is independent of the mains electricity supply (provided a suitable boiler is used)
The main disadvantages of this type of heating system are that a circuit with natural circulation of the coolant offers a low level of comfort and reliability.
Filling and commissioning a closed heating system
A forced-circulation heating system has several key functions:
1. When a system fitted with a boiler and a circulation pump is in operation, the pressure always exceeds atmospheric pressure.
2. Before the system is commissioned, it is subjected to a pressure test at a pressure one and a half times the working pressure. Pressing is particularly important for underfloor heating systems that are installed within the screed. It is important that the underfloor heating is pressure-tested by a specialist.
Before pouring coolant into a closed heating system, you must take these factors into account and consider the procedure for carrying out the work.
In buildings with a central water supply, the issue of pressure testing is resolved in a very simple way. To this end, the heating system is connected to the water supply via a bypass and is filled whilst the pressure is continuously monitored on a pressure gauge. Once the system has been pressurised and checked for leaks, any excess water is drained via a valve or air vent.
It is a completely different matter if water is poured into the heating circuit by hand, or if various types of antifreeze are used as the heat transfer fluid. Before pouring coolant into a closed heating system, in most cases it is sufficient to use a pump that allows you to top up the coolant and pressurise the circuit. The pump is connected via a valve, which closes once the required pressure has been reached.

However, it is possible to fill the system without a pump. To achieve a pressure of 1.5 atmospheres in the system, you can make use of the fact that this value corresponds to a 15-metre water column. With this in mind, before filling a closed heating system with coolant, you can solve the problem in the simplest way possible – connect a reinforced hose to the drain valve, raise it to a height of 15 metres and fill it with water.
The coolant in a country house’s heating system can be replaced using an expansion tank. This component is designed to accommodate excess fluid during thermal expansion. A diaphragm tank is a structure in which two chambers are separated by a movable diaphragm. One part of the tank holds the coolant, whilst the other contains air. Each tank is also fitted with a valve, which can be used to increase or decrease the air pressure.
The heating system is filled with water using the tank as follows:
1. First, all the air is completely removed from the tank; to do this, simply unscrew the plug. The pressure in standard tanks is 1.5 atmospheres.
2. Water is poured into the system. It is not necessary to fill the tank completely – the volume of air should be approximately 1/10 of the total volume of coolant in the system.
3. Air is pumped into the tank using any type of hand pump. The pressure is continuously monitored by a pressure gauge.
Methods of laying heating pipes
In a cottage’s heating system, pipes can be laid in two ways:
Open-lay method

In this case, they are laid along the walls, parallel to the skirting boards. They are visible along their entire length.
Advantages of this method:
- Access to pipework without dismantling structures
- Low heat loss
- Simple heating installation
Main disadvantages:
- Pipes often spoil the look of a room; they don’t fit in with the design
- To prevent bending and deformation, not all types of pipes can be used.
Concealed installation method

The pipework is embedded in the wall or floor, or clad with an external finish.
The main advantages of concealed pipework:
- The ability to conceal motorways so that they do not spoil the interior
- The ability to use pipes made from modern materials
The disadvantages include:
- Access to the pipework is difficult should it be necessary to carry out repairs, replace individual sections or rectify emergency situations
- Due to the high heat loss through the pipework, it is necessary to insulate it
Only reliable and tried-and-tested pipes should be used for concealed pipework. Cross-linked polyethylene pipes are the best option.
Coolant must only be filled using this method after the heating system has undergone a hydraulic test.
Basic rules for installing heating pipes
It is important to bear in mind that the pipework is laid after all heating appliances have been installed in their designated locations. The optimal sequence of installation is as follows:
Marking of heating pipe penetrations
It is better to do this in advance, before installation. During the marking-out process, installation difficulties caused by the cottage’s architectural and structural features are usually revealed. Once you are aware of them, you can prepare in advance to resolve them or alter the route of the lines.
Motorway crossing markings are most commonly applied to walls. In some cases, they may be painted on the floor, but in such cases they may be covered up by people walking through the area.
Fitting of the necessary technical openings and strobes
It is also better to complete this stage in advance across the entire front of the piece. When marking out, the positions of the necessary holes and the lightning conductors are determined.
The grooves can be cut out using a cutter. If this tool is not available, mark them out first with a grinder and then cut them out using a hammer drill.
Thermal insulation of pipework
This needs to be done if you are installing concealed pipework. The main purpose of insulation is to prevent heat loss and improve the efficiency of the system as a whole.
Insulation is carried out using a special thermal insulator, which is manufactured to fit the pipe’s diameter. It is fitted onto the pipes by hand at the installation site. Rubber-based thermal insulation is the most effective and durable. However, it is also more expensive than similar products.
Laying and securing pipes to building structures
Pipes must be secured not only where they are exposed but also where they are concealed within the heating system of a private holiday cottage.
In an open installation, the pipes are secured to the walls using special clips. Self-tapping screws or nails are used as fasteners (depending on the wall material).
Where concealed pipework is installed, the pipes are fixed to the wall in grooves or to the floor using special clamps or perforated tape. If the pipework consists of several pipes, for example those branching off from a manifold, they must be secured in loops. The fasteners used in this case are the same.
Connection to heating systems
Depending on the radiator’s design, pipework can be connected to it either directly or using a Multiflex hose. In either case, the connecting fittings included in the kit are used for the connection.
In a manifold system for a private house’s heating system, the connection is made not only to the heating appliances but also to the underfloor manifolds. As in the previous case, the connection is made using complete connection fittings.
Hydraulic and pneumatic tests
This is an essential part of the installation work. During this process, the system is filled with water or air. A positive pressure is then created within the system using a special pump or compressor (~1.5 bar when testing with water). An hour later, the results are recorded – there should be no drop in pressure.
If the pressure in the system drops during the test, any leaks are identified. Work is then carried out to rectify the causes of the leaks. Hydraulic tests are then carried out on the system again.
Sealing holes
The pouring of the floor screed and the sealing of the channels created by concealed pipework should only be carried out once the hydraulic tests have been successfully completed. This constitutes general construction work. The sealing of the chases is usually done by hand, most commonly using plaster.
Advantages and disadvantages of corrugated steel pipes for heating
As well as stainless steel, corrugated pipes can be made from plastic or cast iron (products with external ribbing). Plastic corrugated pipes are not the best option for carrying coolant. In heating systems, they are more commonly used as additional protection for main services, for example, where they pass through a concrete screed. Cast iron corrugated pipes withstand thermal loads well, but are gradually falling out of favour due to their heavy weight and the complexity of installation.
Therefore, flexible stainless steel heating pipes are the best choice amongst all types of corrugated pipes. Their use offers the following undeniable advantages:
- Corrugated stainless steel pipe is very easy to bend and requires no additional equipment or materials. The pipe can be bent without compromising the integrity of the walls, meaning the structure can take on almost any shape. Thanks to this corrugated feature, it is possible to install the heating pipework with a minimum number of bends and joints, which significantly reduces its cost;
- Stainless steel does not corrode, which means that the service life of such a system is several times longer than that of pipework made from ordinary ‘black’ steel. Furthermore, fluctuations in temperature and pressure are also not a problem for stainless steel heating corrugated pipes;
- Ease of installation is a feature that often attracts supporters of corrugated pipes for heating systems. Connections are made using brass fittings with O-rings made from various materials. When carrying out repairs to specific sections of the pipework, it will also be straightforward to replace a component of the system;
- When extensive work is required, the almost unlimited length of the pipe will be a significant advantage. Stainless steel corrugated pipes for heating are supplied in coils of up to 50 m. This should be sufficient for the installation of any pipework, but longer coils are also manufactured to order.

One of the most important advantages of corrugated pipes is their high flexibility, which allows you to save on bends and fittings.
Important! The maximum working pressure for stainless steel corrugated pipes is 50 bar; the critical pressure is 250 bar. The normal working pressure for hot media is 15 bar. Corrugated pipes for heating can easily withstand temperatures of up to 110 degrees, which is comparable to the properties of modern reinforced polypropylene constructions.
Like any other product, flexible stainless steel pipes for heating systems also have certain drawbacks. It is up to the buyer to decide how serious these are:
- low impact resistance. If corrugated stainless steel heating pipework is installed in areas of a house or flat where there is a risk of mechanical damage, it is recommended that a protective sleeve be used;
- Difficulties with removal. It is slightly more difficult to clean dust from corrugated structures than from tubes with smooth walls. Cleaning will need to be carried out with a brush or, better still, by enclosing the corrugated section in a protective box or screen beforehand;
- Not the most aesthetically pleasing external component. When developing the corrugated metal heating pipe, manufacturers paid greater attention to the products’ functionality than to their appearance. Stainless steel pipes can hardly be described as particularly attractive, but for those who are not satisfied with this drawback, there are many ways to conceal the heating pipes.
Collector heating circuit (beam, fan).
In a manifold system, each heater is connected to the manifold by two pipes – a supply pipe and a return pipe.
The main advantage of collector heating is that the circuit allows the temperature of the coolant to be regulated at each individual heating unit or in each of the circuits within the underfloor heating system.
When using heating pipes made from modern materials (such as cross-linked polyethylene or metal-plastic composite), there are no pipe joints between the manifolds and the heating units. This increases the reliability of the system. In this case, you do not need to worry about leaks forming in the cavities. The manifold circuit for heating a private house is installed exclusively as a concealed system. In holiday homes, this type of installation is more popular than others.
Requirements
The technical characteristics required of heating pipes are primarily determined by their operating conditions. Let’s find out under what conditions the heating system will operate.
Temperature
- For central heating systems, the limit is set by the current SNiP … In no engineering system of a residential building may the temperature exceed 95 °C. In pre-school facilities, the maximum temperature limit is even lower: no heating pipe or radiator should be heated to above 37 °C.
Meanwhile, in the real world: under certain conditions, coolant can still enter the radiators by bypassing the mixing chamber in the lift unit. Yes, this is a force majeure situation; nevertheless, the theoretical maximum that a paranoid flat owner should take into account is 140 C.
- In autonomous heating systems, the temperature does not usually exceed 75–80 degrees … Furthermore, long sections of heating pipework embedded in the screed can act as a water-heated underfloor heating system, for which a temperature of 35 degrees is sufficient.
Pressure
- For hot-water central heating systems, an operating pressure of 4.5–5.5 kgf/cm² is standard during the heating season … However, when designing the system, it is again advisable to take force majeure circumstances into account: in the event of a fault with the shut-off valves or poorly trained service personnel, a water hammer may occur, which can briefly raise the pressure to 20–25 atmospheres.
- Pipes in independent circuits are subjected to much lower loads … For these, the standard is 1–1.5 kgf/cm². The pressure is absolutely stable: in a closed system, with the owner exercising even a minimum of care, there is simply nowhere for water hammer to come from.
Two-pipe system
Heating a house using a two-pipe system involves connecting the radiators in series. At the same time, the pipes are shared by all the heating units.
There are two ways of implementing a two-pipe system:
Double-pipe transition (Tichelman loop)

The coolant flows in the same direction in both the forward and return circuits. The return loop begins at the first radiator and the supply loop ends at the last one. The correct flow of the coolant is ensured by selecting the appropriate pipe diameter. By using a Tichelman loop, you can achieve uniform heating of the rooms.
Double-barrelled, blind-ended

It differs from the previous type in that the coolant flows in multiple directions through the forward and return circuits, and consists of several branches. The final radiator in each branch is a dead end. The return circuit begins at this radiator.
A two-pipe closed heating system is more difficult to install than a looped system. Careful calculation of the system’s hydraulic components is required. Furthermore, it is essential to ensure that the load is evenly distributed across each branch. It is recommended that each branch be fitted with no more than five heating units.
The advantage of two-pipe systems is their low purchase price and operational reliability (compared with single-pipe systems).
One of the drawbacks worth highlighting is the need for a large number of connections to the heating pipes. This significantly reduces the system’s reliability and is particularly important in the case of concealed installation.
Furthermore, there is no option to adjust each heater individually, which often makes it impossible to set the desired temperature in a particular room.
In a dual-pipe electrical installation, the wiring can be laid either exposed or concealed. In the former case, copper or polypropylene pipes are usually used; in the latter, cross-linked polyethylene pipes are used. Cross-linked polyethylene is used because it ensures a more reliable connection between the pipe and the fittings.
Methods of connecting radiators
The main task when choosing a heating system is to identify the right option that offers the best balance between efficiency and cost. To this end, the designer has at their disposal various types of electrical installation, methods of connecting the radiators, the positioning of their inlet and outlet pipes, and their location in relation to the boiler, heat storage tank or hot water tank.
A single pipe
A single-pipe radiator connection is one of the cheapest ways to heat a property; in this system, heat is supplied sequentially to each radiator. From the outlet via the return pipe, the working fluid enters the boiler and, after being heated, is sent back to the radiators, thus completing a circular cycle.
The single-pipe system is widely used both in high-rise buildings and in private housing, for heating cottages and summer houses. Its advantages include minimal use of materials, whilst a significant disadvantage is uneven heating – the liquid entering the radiator is at the lowest temperature, being the very last in the circuit.

Fig. 2 Connection of radiators in a single-pipe system according to the Leningrad scheme
Various engineering solutions, which are used with equal effectiveness in both communal and private housing construction, help to address the problem of uneven heating in single-pipe systems. The correct connection of radiators to a single-pipe system involves choosing one of two popular ‘Leningrad’ layouts – with outlets connected at the bottom or diagonally.
In Leningrad, the sequential connection of radiators is implemented as follows: the pipework runs along the underside of the floor from the boiler outlet to the inlet, forming a closed loop, and all heat exchangers are connected to it in parallel. via the lower (upper) inlet and outlet fittings.
Connecting a radiator to a single-pipe heating system with a bypass is widely used in blocks of flats and private homes; to achieve this, inlet and outlet valve assemblies are fitted at one end, and a small-diameter vertical connector is cut between the supply and return pipes (bypass shown on the left in Fig. 9).

Fig. 3 Horizontal connection options for radiators in a two-pipe system
Double-barrelled
The use of two pipes helps to overcome the main drawback of a single-pipe system – uneven heating of the heat exchangers. In a two-pipe electrical installation, two pipes are used: the first supplies the heat transfer fluid to the heating appliances, whilst the second forms part of the return pipe and carries the cooled fluid back to the boiler. The temperature of the second pipe in a two-pipe heat exchanger system therefore differs in practice very little from that of the first. Two-pipe systems are not used very often in general housing construction; in private housing, however, there are several connection options, the main ones being dead-end and combined connections.
In a looped system, the radiators are connected in series from the boiler via the supply and return pipes; the further away a radiator is located, the longer the distance the heat transfer medium must travel to reach it. The final radiator in the circuit is connected at the point furthest along the pipe – this results in the radiators being heated unevenly in this configuration.
Single-tube circuit (“Leningrad”)
A single-pipe heating system is an outdated design, but it is still sometimes used. It uses a single pipe that forms a loop. Radiators are connected in series to this pipe. The coolant is supplied to the radiators via this pipe and returns to the boiler through it.
The only advantage of the ‘Leningrad’ system is its low cost. A significant drawback is the variation in coolant temperature across the radiators. The radiators furthest from the boiler do not heat up sufficiently. In today’s reality, the Leningrad system is practically never used for heating in private homes precisely for this reason.
Materials used in heating pipes
When designing the system, the material of the pipes is selected depending on the method of installation. This is due to their thermal expansion and elasticity.
For example, steel pipes can be installed both indoors and outdoors. Cross-linked polyethylene and metal-plastic pipes are recommended to be laid concealed. Laying them in the open is undesirable, as their significant deflection detracts from the aesthetics of the interior. It is recommended that polypropylene pipes be laid in the open. Otherwise, any leaks at the joints may not be detected in time.
Next, we will take a closer look at the main types of heating pipes and outline their main advantages and disadvantages.
Cross-linked polyethylene

Modern technologies for manufacturing pipes from this material make it possible to achieve high performance characteristics. Pipes manufactured using the cross-linking process are designated PEX.
Leading manufacturers of XLPE pipes produce extruded fittings for them. These are corrugated using a special tool. The resulting fittings are highly durable.
Advantages:
- Flexibility, tensile strength, and the ability to return to its original shape even after severe deformation
- Ability to withstand high pressure – up to 10–12 atmospheres
- Simple installation of a heating system using these pipes
- It withstands high temperatures and harsh environments
Disadvantages:
- UV vulnerability
- The softness of the coating (which can lead to mice and rats gnawing through the pipe walls). This is one of the reasons why such pipes are mainly used for internal installations. It is recommended that they be laid underground in metal casings.
- XLPE pipes and fittings are relatively expensive
- The high cost of a tool for joining pipes to fittings
Polypropylene

It is a lightweight material derived from petroleum products. Both the pipes themselves and the fittings are manufactured from it. The pipes are joined together by soldering.
Advantages:
- Low price
- Resistant to aggressive chemicals
- Ease of installation
- Low price of a soldering tool
Disadvantages:
- Deterioration of properties due to exposure to sunlight
- Flammability
- Sensitivity to high (above 70 degrees C) coolant temperature
- Short service life
The installation of a heating system in a private house using polypropylene pipes is carried out using an exposed layout for the internal heating system.
Modern polypropylene pipes are reinforced to improve their performance and reliability. The reinforcing materials are fibreglass or aluminium. The best option for heating applications is glass-fibre-reinforced polypropylene.
Metalloplast

The name of the material reflects its structure. It consists of layers of polyethylene, aluminium and an adhesive layer. Pipes made from this material are used with brass fittings.
Advantages:
- High strength
- Shelf life
- It is resistant to high temperatures, sunlight and harsh environments
- Flexibility
- Easy installation of metal-plastic pipes
Disadvantages:
- Poor pressure resistance in the system
- Relatively high costs
- Thermal deformation behaviour
- Delamination when the maximum permissible pressure is exceeded
- The high cost and versatility of the material-working tool
Heating systems in private homes using metal-plastic pipes are mainly used for internal installation.
Steel

This material is traditionally used in the manufacture of heating pipes. Until recently, almost all pipes used for space heating were made exclusively from this material. The pipework is connected by welding or using threaded fittings.
Advantages:
- High strength, resistance to mechanical stress
- The ability to withstand any temperature and pressure of the coolant
- Low price
- Low coefficient of thermal expansion
Disadvantages:
- The time-consuming and complex installation of a heating system in a private house using these pipes
- Lack of flexibility
- Susceptibility to corrosion
- Internal ‘overgrowth’
- Its service life (compared with modern materials) is relatively short – up to 15–20 years, depending on operating conditions.
Copper

Heating systems based on copper pipes are rare. This is because such pipes are expensive.
Advantages:
- High strength; resistance to mechanical stress, high temperatures and high pressure
- Long service life
- No corrosion
- Aesthetics (with open upholstery)
Disadvantages:
- High cost of materials
- Sensitivity to the presence of contaminants in the coolant and its composition
- The time-consuming installation of a heating system in a house
- Negative galvanic processes when joining certain materials
It should be borne in mind that it is not permissible to install copper pipes before steel pipes and radiators. This leads to adverse galvanic reactions. To prevent this, copper pipes must be laid after the steel sections along the flow of the coolant, or a galvanic seal must be made from a neutral material (such as bronze or brass).
Stainless steel
Heating a house with stainless steel pipes is considerably more expensive, but they do not have one of the main drawbacks – susceptibility to corrosion. As a result, stainless steel pipes last much longer and can be used in almost any heating system. However, they are very expensive and are used only in very rare cases.
Corrugated pipes
These are corrugated, flexible stainless steel hoses. They are not often used in heating systems. They are sometimes used as supply pipes to radiators or convector heaters when, for some reason, it is difficult to use standard pipes for this purpose.






Plastic heating pipes, PVC and flexible polymer pipes

No heating system can function properly without pipes. They are to the system what veins and arteries are to the human body. Therefore, the selection of pipes to be used in the heating system should be approached with the utmost care. Recently, plastic pipes have been used increasingly often for heating installations. They come in two types – polypropylene and metal-plastic. Of course, every type of plastic heating pipe has its own advantages and disadvantages. Let’s consider them in more detail.
Reinforced plastic pipes for heating systems

As the name suggests, metal-plastic piping is made not only from plastic, but also from metal. This means that the inner and outer surfaces of the plastic heating pipe are made of high-quality plastic, with a thin layer of aluminium between them. It is thanks to this layer that the pipework is able to withstand the high temperatures and pressure present in the system.
There are three types of metal-plastic pipes available on the market today: for cold water, for hot water and for heating. Reviews of these pipes vary greatly. Of course, they all differ in performance and price. These may include PVC pipes for heating, PP pipes for heating and others.
The ‘weak point’ of metal-plastic pipes can be said to be their joints. The fact is that the pipes are assembled using special threaded fittings, which are fitted with rubber seals to ensure a tight seal. The problem, however, is that constant exposure to high temperatures significantly shortens the service life of such seals. Consequently, 2–3 years after installation and commissioning, such a rubber seal should be replaced. Otherwise, a leak may occur at the most inopportune moment. It is therefore unacceptable to use this type of joint in heating systems where flexible heating pipes are laid inside walls.
The advantages of metal-plastic pipes include their low cost, availability and flexibility. Furthermore, polymer heating pipes are quite thin, making them virtually invisible within the interior.
Polypropylene pipes for heating systems

Recently, polypropylene pipes have been used more and more frequently in heating systems. And this is hardly surprising, as the number of advantages far outweighs the number of disadvantages. Firstly, plastic heating pipes are not joined using fittings with rubber seals – they are soldered using specialised equipment.
As a result, heating systems using plastic pipes are more durable – the absence of rubber seals significantly reduces the likelihood of leaks.
Another advantage of polypropylene pipes is their long service life (over 40 years).
Furthermore, fibreglass heating pipes are relatively affordable, both in terms of their availability (meaning they can be bought in almost any building supplies shop) and their price.
All these features make plastic heating systems the most sought-after option for private homes when installing heating systems. There are currently several types of pipes of this kind available on the market, namely:
- PN16 and PN25 – these two types are not used in heating systems as they have a relatively low permissible temperature limit. This means that, following prolonged contact with hot coolant, such pipework may become unusable.
- Composite pipework. It is the ideal solution for heating systems, as it withstands high temperatures and pressures perfectly. The advantage of composite pipework is that it is made from high-quality polypropylene with a thin metal layer. This means that it is, in fact, metal-plastic pipework in which polypropylene is used.

This means that a composite pipe differs from a standard polypropylene pipe in that it contains a metal insert, and from a metal-plastic pipe in that it is made of polypropylene. In fact, it is a kind of hybrid. At the same time, this type of pipe is highly resistant to high temperatures and pressure – which makes it ideal for heating systems.
Composite pipes are often referred to as stabilised and are divided into several types:
- deeply stabilised – that is, an intermediate layer which makes the pipe exceptionally ‘durable’.
- with an outer layer – the metal is situated quite close to the outer layer of the pipe.
There is a difference with these ovens, and it’s quite a big one.
Firstly, the metal coating on pipes with external stabilisation is more of a disadvantage – after all, the metal should be removed before soldering the pipes together in sections, as it simply prevents the joint from being as tight as possible.
If the intermediate layer is not removed, the pipe may delaminate in the future – and this leads to an urgent need to replace the damaged section. Plastic heating pipes with a deep-seated stabilising layer, on the other hand, do not have this problem – they are easy to solder and do not swell (or flake off) during operation.
Aluminium or fibreglass can be used as a stabilising material. Of course, HPVC heating pipes made from the second type of material are more expensive. However, there isn’t much difference – after all, both materials perform excellently in the roles assigned to them.
It should be noted that, despite their many positive qualities, plastic heating pipes still have a number of drawbacks. Firstly, however high-quality they may be (and whatever the manufacturer may claim), a slight degree of deformation does occur during operation. Furthermore, polyurethane heating pipes have a relatively high level of heat loss. However, this can be mitigated by a Merylon sleeve, which is often used when installing heating system pipework concealed within the structure. It significantly reduces heat loss and helps to minimise deformation.
Heating equipment
Various types of heating systems can be used to heat water in the home – radiators, convector heaters, air diffusers and underfloor heating. We will describe each of these systems in more detail below.
Radiators

Radiators are the most common type of heating appliance. They can vary in the number of sections (there are also non-sectional radiators) and in the materials used. The larger the front surface area, the more heat the appliance generates.
Radiators are categorised into the following types:
- Steel
- Panel
- Tubular
- Bimetallic cross-section
- Aluminium sectional
- Cast iron
They may have the following type of connection:
- Lower
- Side
- Diagonal
Convector heaters

As well as radiators, a house can be heated using water-filled convector heaters. Their operating principle is based on the fact that heated air rises and displaces cold air. This phenomenon is called convection, which is where the name of this device comes from. Convectors are usually installed beneath windows. The warm air flowing out of them creates a ‘curtain’ that blocks the flow of cold air from outside.
Depending on where they are installed, convector heaters can be:
- wall-mounted
- Standing on the floor
- Inserted
Wall-mounted appliances are fixed to the wall using special brackets. As they are lightweight, they can be installed on plasterboard partitions, unlike radiators.
Floor-mounted convector heaters are installed on the floor using the legs supplied. They are compact in size but offer high heat output.
Built-in convector heaters are installed in a recess beneath the floor. The grille at the top of the unit is flush with the floor. In some cases, this grille is decorated to match the style of the interior.
Depending on the type of convection, convector heaters can be categorised as follows:
- Natural convection
- Forced convection
In the first case, currents of warm air flow upwards, whilst cold air flows downwards due to the difference in density; here, however, they are heated by the converter. This process then continues cyclically, in a natural manner.
In models with forced convection, electric fans are built into the units. The operation of the fans accelerates the convection process and increases heat transfer.
Convector heaters generally look more aesthetically pleasing than radiators, and built-in models are completely hidden from view (apart from the grille). They are therefore often installed where design is a key consideration. They are also used where it is not possible to fit traditional radiators, e.g.
- In front of the glass balcony doors
- With ‘low windows’
Convector heaters are often used not only to heat living spaces, but also in swimming pools and conservatories.
Registers
Another type of heating system is radiators. These are welded or assembled structures made from metal (usually steel) pipes. The pipes are connected to one another by joints through which a coolant circulates. Cottages are rarely heated by radiators due to their unattractive appearance. Radiators are most commonly used in industrial facilities.
Heating a house with underfloor heating
In recent years, water-heated underfloor heating has been growing in popularity. If a room is large, radiators do not always heat the whole space effectively, particularly in the centre of the room. In this case, it is advisable to install underfloor heating in addition to radiators. The warm air rising from the underfloor heating will fill the entire space evenly.
Choosing a heating system layout
Heating system layouts refer to the ways in which heating pipes are laid and radiators are connected to them. The setting (balancing) of the heating system, the flow rate and the routing of the heating pipes depend on the type of heating system layout.
There are three basic types of heating system: single-pipe (Leningrad-style), two-pipe and radial.



A single-pipe heating system (Fig. 2) consists of a single pipe to which the radiators are connected. The pipe runs around the perimeter of the house and is connected to the boiler. In this layout, pipework usage is minimal. The disadvantage is that each subsequent radiator will provide less heat than the previous one, and it is very difficult to distribute the heat evenly amongst them.
A two-pipe heating system (Fig. 3) consists of two pipes: one supply pipe and one return pipe. The radiators are connected to the supply and return pipes. It can be seen that the radiators are connected in parallel and heat is distributed evenly amongst them. This layout is easy to adjust, which is why it is the most commonly used.
The beam layout (Fig. 4) differs from the two-pipe independent connection of radiators. Manifolds are used for this purpose. In this case, each radiator can be individually controlled, which helps to reduce heating costs. Under this layout, the underfloor heating is connected to a water-based system. The disadvantage is the high consumption of heating pipes.
Other components of the heating system
In addition to pipework and heating appliances, a house’s heating system may include the following components.
Circulation pump
A circulation pump is used in systems with forced circulation of the coolant. A circulation pump is installed on the return pipe between the boiler and the nearest radiator located along this pipe.
It works as follows. The pump motor is driven by a rotating impeller. The pump begins by drawing coolant from the circuit on one side and forcing it through the pipework on the other.
Expansion tank
It is a steel tank with two chambers inside. These chambers are separated by a membrane. One of them is designed to be filled with water, whilst the other serves as an air expansion joint.
Expansion tanks are installed in closed-loop heating systems to compensate for any water hammer.
Buffer capacity
Its purpose is to supply heated coolant and ensure that the heating system continues to operate for a certain period of time whilst the heat source is switched off.
Solid-fuel heating in the house works optimally when this tank is used. During the day, whilst the solid-fuel boiler is in operation, the coolant is heated in the buffer tank. And at night, the cottage can be heated from this tank whilst the boiler is switched off, as the coolant has not cooled down.
Tips for connecting batteries in a diagonal configuration
There are two main methods of heating homes – gravity-fed and forced circulation. In a gravity-fed system, hot coolant from the boiler rises independently through a riser pipe, at the end of which an open expansion tank is installed (usually located in the loft of a private house). The gravitational movement of the water occurs because the hot fluid, having expanded as a result of heating, has a lower density and is therefore pushed upwards by the cooler fluid below. The heated water then flows into the radiators installed below the expansion tank, with all supply pipes required to have a certain gradient.

Fig. 7 Gravity-fed two-pipe heating system – radiator connection diagram
Diagonal diagram in gravitational systems
In separate (gravity-fed) circuits, it is theoretically possible to use a series diagonal connection of radiators, with the inlet flow entering via their upper outlet and the outlet flow exiting via the lower outlet on the opposite side. Water can be channelled downwards from the last radiator back to the boiler, which is usually located in the basement. A significant disadvantage of this arrangement is the temperature difference between the radiators closest to the boiler and those further away; due to the series connection, thermostats are unable to compensate for this, which is why the number of battery units with this type of connection is limited.
This disadvantage can be avoided by using a parallel twin-pipe connection for the radiators to the supply and return pipes. With this connection, a separate pipe is connected to the top of the expansion tank on each radiator; similarly, separate pipes from each unit are connected to the boiler, forming a single system. In this system, it is possible to maintain the same temperature in each heat exchanger using thermostats or by balancing the flow via valves that regulate the volume of coolant flowing through each unit.
The main disadvantages of gravity circuits are the low height of buildings (no more than two storeys), the small number of heat exchangers that can be installed due to restrictions on pipe length, and the inability to install underfloor heating.

Fig. 8 Heating system with forced diagonal heating
Diagonal in forced systems
In forced circulation systems, an electric circulation pump (usually located in the return pipe) is connected to the pipework to circulate the coolant; this pump drives a stream of water via its impeller with blades. This means you do not need to install a slope, nor do you need to bring a large, open expansion tank into the loft (instead, a small, sealed hydraulic accumulator is fitted), and it is possible to fill the system with a toxic antifreeze mixture – ethylene glycol. As a diagonal connection is the most efficient (in terms of heat transfer) for radiators, it is used quite frequently, although it is less aesthetically pleasing than other options.

Fig. 9 Vertical ducting in multi-storey buildings
Heat carrier
The main types of heat transfer media used in heating systems are water, various antifreeze solutions and mixtures of these in specific proportions.
Antifreeze is a liquid consisting of an aqueous solution of ethylene glycol, propylene glycol or potassium acetate, with the addition of modifying additives. These lower its freezing point.
Heating a house using coolant to which special inhibitors have been added prevents oxidation, corrosion and limescale build-up. Their concentration can range from fractions of a per cent to 3–4 per cent by weight.
The choice of coolant is decided on a case-by-case basis, depending on the situation. If the likelihood of a boiler breakdown is low and there are no issues with the fuel, it is better to use water. Many boiler manufacturers prohibit the use of antifreeze; warranty claims are frequently rejected on this basis.
How is the coolant replaced in the heating systems of various types of heating systems?
Contents:
Reasons for filling and resetting the system; Starting the heating system in a block of flats; How to start an open gravity heating system; Filling and starting a closed heating system; Calculating the volume of coolant; Conclusion
When installing or repairing a heating system, sooner or later it becomes necessary to fill the circuit with coolant. Furthermore, it is sometimes necessary to carry out the reverse operation, i.e. to drain the coolant. Various situations arise, and there are a number of factors which determine the different methods that can be used to fill the system with water. This article will discuss how to change the coolant in a heating system.
Preparatory work
Before work begins on installing the heating system in a private house, preparatory work must be carried out. The aim of this is to minimise any downtime for the installation team during the installation process. The preparatory work includes:
- Ensuring the site is ready for construction – the heating circuit must be sealed, the premises must be cleared of building rubble, and sub-floors or timber sub-floors must be in place
- Layout of recesses for the installation of radiators and distribution boxes – where necessary
- Preparing the wall surface for fitting radiators – a smooth finish is best
- Complete refurbishment of the boiler room
- Cutting all the necessary holes in the floors, creating grooves and recesses
Radiator wiring diagrams
Every standard radiator has four outlets for connection to the pipework, the only exception being steel models with two lower outlets – this allows them to be integrated into any pipework layout that is most advantageous for the consumer in terms of cost and design. In addition to the diagonal method, other methods of connecting radiator heat exchangers to pipework are also used.
Lower
Metal radiators with a special unit at the bottom (telescopic) and a corresponding internal design can be connected to the heating system at the lowest point. This method of connection is sometimes also used in aluminium sectional radiators, but in such cases water is additionally fed into the upper branch pipe via a bypass bridge. In both cases under consideration, when connecting to the heating system, the heating units are connected from below on one side; therefore, this type of installation is referred to as ‘bottom single-sided’.
The popular method of connecting radiators in a single-pipe system – the ‘Leningrad’ system – is also carried out from below, by attaching the heat exchanger fittings to the main pipe. If you connect to the circuit from the bottom, the heat transfer efficiency of the Leningrad system drops to 88 per cent, with a further 10 per cent reduction when the pipes are positioned on one side only, as is appropriate from the bottom.
The main advantage of underfloor units is the aesthetic appearance of the radiators, without compromising the design of the pipework when installed beneath the screed.

Fig. 6 Side and bottom connections of a radiator in a two-pipe system for private homes