Common error codes in gas-fired boilers
![]()
Contents
- Gas prospects
- Reason nine. Fault in the control panel (board)
- Installation details
- How do you clear error 01 on an Immergaz gas boiler?
- A bit more about electricity
- Meaning of error E01
- Electronics
- What is error code E01 in relation to Baxi boilers?
- Automation
- Causes of faults during boiler operation
- Errors and their codes
- The most common error codes for Baxi boilers
Gas prospects
The use of gas for heating houses and flats is currently one of the most promising trends in the development of utility networks. Boiler manufacturers offer so many options that you can choose the right unit for absolutely any room. BAXI boilers are a case in point.
Non-destructive
deterrence of
rodents,
wildlife
and snakes.
BAXI gas boilers can be installed in any room. They are suitable both for installation in flats and for heating a large country house. Naturally, the room in which the mini-boiler room is installed must meet the relevant requirements:
- The room must have a volume of at least 15 cubic metres.
- Ceiling height – at least 2.2 metres.
- Good ventilation, capable of ensuring a threefold air change.
Existing requirements regarding chimney installation can be disregarded if you choose a BAXI boiler with a sealed combustion chamber to heat your home. Such a unit is a fully-fledged mini-boiler room, which has all the necessary components and does not adversely affect the building’s environmental performance. Models from this manufacturer vary in terms of performance, so BAXI boilers can be used for heating and hot water supply in a variety of spaces.
Reason number nine. Fault in the control panel (board)

If you have ruled out all previous causes or have rectified the faults listed, and the Baxi boiler still displays error E01, you should contact the service centre to have the circuit board itself diagnosed. This circuit board contains all the modules it needs; if one of them fails, all the others will trigger an E01 error.
It follows that the problem may once again lie in incorrect assembly or faulty components supplied by the manufacturer during the soldering of the motherboard itself.
Installation details
Installing an appliance – particularly indoor wall-mounted models – may seem very straightforward at first glance. In practice, however, this is not entirely true. BAXI boilers use gas as a fuel, and whilst gas has many undeniable advantages, it remains a hazard. Gas appliances require a professional approach. A single installation error, even the smallest one, can lead to serious consequences. The appliance should only be installed by qualified personnel with the necessary expertise.
Even a brief list of the consequences that can lead to the disruption of gas supply looks daunting. The most common are:
- The system freezing in winter.
- Explosions.
- Fires.
- The release of carbon monoxide into the air in living spaces.

Front-panel display
BAXI boilers, like any modern gas appliance, are of course fitted with safety systems, but even automation cannot always cope with errors made by a non-professional. When it comes to less serious consequences, the main problem with DIY installation is incorrect boiler operation. For example, the boiler may fail to switch on and display error codes, even though all its components are functioning correctly.
BAXI gas boilers – portable appliances. They cannot operate without being connected to the mains. The connection requirements are very straightforward; they are no different from the rules for installing standard domestic electrical appliances. … The unit is connected to a 220V mains supply and must be earthed … It is also best to leave the earthing to the experts. Although a lack of earthing does not lead to serious consequences, it can affect the device’s functionality. The device often displays error codes and the burner fails to ignite due to minor faults in the electrical connection.
If it is not possible to earth the equipment completely (such cases do occur), a stabiliser must be installed to ensure galvanic isolation. In some cases, the potential may pass through the gas pipe. This situation is already becoming dangerous, and the connection must be made via a special adapter with dielectric properties.
How do you clear error 01 on an Immergaz gas boiler?
The Immergaz boiler has suddenly stopped working; the display shows error code 01. I have cleaned the burner and reset the unit’s settings, although I realise this is pointless. When I restart the boiler, it starts up, the burner ignites and then goes out. Then the ignition cycle repeats and the error reappears. Where should I look for the fault? The gas valve is broken. If damage is found, the gas valve must be replaced. The ionisation electrode is not working properly or is out of order. Check for carbon deposits on it. If necessary, adjust the distance between the burner assembly and the ignition electrode. The gas valve is broken. Check the gas valve coils for any potential short circuits or open circuits. If any faults are found, replace the gas valve.
The gas valve is stuck. Connect the rubber hose to the coupling on the front of the valve and apply firm pressure. Incomplete ignition. Adjust the ignition power via the service menu. Fault or malfunction of the control board. The ignition transformer has stopped working. Restart the appliance. If the fault reoccurs, the control board must be replaced.
Check the earthing. The cladding must be potential-free. Excessive moisture can cause the appliance to shut down. Clean any condensation from the combustion chamber, the ionisation electrode and the burner. Ignition electrode fault. The control board has detected a flame, but combustion is not taking place. Check the ignition electrode connection. There may be loose contacts or breaks. Check the electrical circuit from the ignition electrode to the control board for a short circuit. The ignition electrode is touching the gas burner. Faulty control board. It needs replacing.
Similar questions
- How to reset error code A5 on an Arderiya gas boiler
- How to clear error code 108 on an Ariston gas boiler
- How can I reset error code E10 on a Baksi boiler?
- Why might a Beretta gas boiler overheat and make a loud humming noise?
- Why is the pressure in a Bosch gas boiler dropping?
- For some reason, the Buderus boiler is not operating in hot water mode
- Why is the pressure dropping in a Celtic gas boiler?
- Why has my Daewoo dual-circuit boiler started to make a buzzing noise and overheat?
- How to resolve error E4 in an Electrolux boiler
- Why is the Ferroli gas boiler not providing hot water?
- For this reason, the Immergas boiler keeps switching on and off whilst heating
- Why has my Junkers wall-mounted gas boiler started to make a buzzing noise and overheat?
- Why does the Navien boiler display error 10, and how can it be fixed?
- For this reason, the Neva Lux gas boiler displays error code 03 – how to fix it
- How to resolve error F22 on a Proterm gas boiler
- Why is the Rinnai boiler not working for domestic hot water?
- Why does the Vilant gas boiler display error F36, and how can it be fixed?
- Why does the Wisman gas boiler display error code F4?
- The Electrolux gas boiler is losing pressure; this is a fault
- What is the fault if a Ferroli gas boiler displays error code F05, and how can it be fixed?
- Why has the Arderia boiler started displaying error E2, and how can it be fixed?
- Why was the Ariston gas boiler constantly switching on and off in heating mode?
- For some reason, the Baksi gas boiler isn’t maintaining pressure
- Why did the Bosch gas boiler start displaying error code C6, and how can it be fixed?
- The pressure in the Buderus boiler is dropping; this is a fault
- Why does the Arderia boiler keep switching on and off whilst heating up?
- What is the problem if an Ariston gas boiler displays error 607, and how do you reset it?
- How to fix error code F28 on a Vilant boiler
- Why is the Wisman boiler not providing hot water?
- How to resolve error 43 on a Rinnai boiler
- Because of this, the Neva Lux boiler started to heat up and make a loud buzzing noise
- Why is the Proterm boiler not working for domestic hot water?
- How to resolve error 01 on an Immergaz gas boiler
- For some reason, the Navien boiler is not operating in hot water mode
- How to resolve error E1 on an Electrolux boiler
- How to fix error code F37 on a Ferroli boiler
- How can I resolve error 6A on a Buderus gas boiler?
- Because of this, the Daewoo gas boiler stopped maintaining pressure
- Why is my Bosch gas boiler not working when supplying hot water?
- What is the fault with the Baksi boiler if it displays error code E01?
- My Beretta gas boiler isn’t maintaining pressure – what could be the reason?
- What is the fault with the Arderia gas boiler if it has started displaying error A6?
- The pressure is dropping in the Ariston gas boiler – what are the reasons?
- What are the reasons why a Rinnai boiler might overheat and make a buzzing noise?
- Why did the Wisman boiler keep switching on and off whilst heating?
- For this reason, the Arderia boiler does not operate in DHW mode
- What are the reasons why the Ariston wall-mounted boiler started displaying error code 501?
- What is the problem if a Baksi boiler displays error E03, and how can it be fixed?
- Why does the Buderus boiler display error 3C, and how do I reset it?
- Why does the Proterm boiler frequently switch off and on whilst heating?
- What is the fault with an Ariston boiler if it displays error code 607?
- How can I resolve error code 10 on my Navien boiler?
- What is the problem with an Electrolux boiler if it displays error code E3?
- How to fix error F36 on a Vilant gas boiler
- What is the problem with a Proterm gas boiler if it displays error code F25?
- How to resolve error code F5 on a Wisman gas boiler
- What is the problem with a Ferroli boiler if it displays error code F05?
- How to fix error E03 on a Baksi boiler
- What is the fault with a Bosch boiler if it displays error code C6?
- What is the fault with a Buderus gas boiler when it displays error code 3C?
- What is the problem if a Rinnai boiler displays error 99, and how can it be fixed?
- Why does the Beretta boiler display error code A03, and how can it be fixed?
- Why does the Junkers boiler keep switching on and off in heating mode?
- Why does the Daewoo boiler keep switching on and off whilst it is heating up?
- Why does the Bosch boiler keep switching on and off whilst it is heating up?
- Because of this, the Thermon boiler frequently switches on and off whilst heating up
- Because of this, the Celtic cauldron keeps switching on and off as it heats up
- What is the fault with a Westen gas boiler if it displays error code E01?
- How to resolve error code A01 on a Corestar gas boiler
- How to fix error code F1 on a Senor Duval gas boiler
- How to clear error code A6 on a Celtic gas boiler
- What is the fault with the Elsotherm boiler if it has started displaying error code E1?
- What are the reasons why the Bugatti gas boiler started displaying error code E01?
- How do I resolve error code E2 on a Motan boiler?
- Why does the pressure drop in an Immergaz boiler?
- For some reason, the Kiturami gas boiler has stopped maintaining pressure
- The pressure in the Korea Star gas boiler is dropping – what are the reasons?
- Why does the Mora boiler fail to maintain pressure?
- The pressure in the Navien boiler is dropping; this is a fault
- The pressure is dropping in the Proterm gas boiler – what are the reasons?
- Why does a Rinnai boiler fail to maintain pressure?
- Why does an Ariston boiler display error code 101?
- How to fix error F20 on a Proterm boiler
- What are the reasons why a Daewoo gas boiler displays error code E3?
- How to fix error code 16 on a Navien boiler
- Why does the Electrolux boiler display error code E2?
- How to resolve error F20 on a Vilant gas boiler
- What is the problem with the Beretta boiler if it has started displaying error code A02?
- How to resolve error F2 on a Wisman boiler
- Why does the Neva Lux boiler display error code 02?
- How can I fix error A03 on a Ferroli boiler?
- What are the reasons why a Baksi gas boiler displays error code E02?
- How to fix error E9 on a Bosch gas boiler
- What are the reasons why a Buderus gas boiler displays error code 2E?
- How to fix error E3 on an Oasis boiler
- Why does the Rinnai boiler display error 16?
- Heating boiler pipework
- STS boilers
- KBT solid fuel boilers
- Peresvet pellet boiler
- Raton steel floor-standing boiler
- Termológia solid fuel boiler
- Errors and faults in the Termet gas boiler
- Repair of Thermon boilers
- Repair of Nova boilers
- Hermann Boiler Servicing
- A comparison of the Lemax Premium-20 and Danko-20s gas boilers
- Maintenance of Daewoo boilers
- Demrad boiler faults
- Mora boiler faults
- Repair of a Westen boiler
- Faults with Immergaz boilers
- Types of solid fuel boilers
- Models and designs of combi boilers
- Oil-fired and dual-circuit boilers
- Cast-iron coal-fired boilers
- Boilers with simulation burners
- Imported boilers for heating systems
A bit more about electricity
As well as the need for earthing, there are other considerations to bear in mind when connecting boilers:

Baxi Luna 3 Comfort 240 fi
- The gas boiler unit operates reliably within a voltage range of 170–250 V. If the voltage drops, the boiler switches off; if the voltage rises, the varistor will blow.
- The sine wave in the mains supply must be free from interference. Such appliances do not cope well with power surges. Experts recommend connecting additional voltage stabilisers. It is not necessary to use a UPS when installing gas heaters.
- The connection must be to a separate machine.
- In phase-dependent models, it is important to ensure that the zero and phase conditions are satisfied.
Meaning of error E01
Code e01 is one of the most problematic. It indicates the absence of a burner flame, even though one may actually be present but of low intensity. In any case, the ionisation sensor cannot rectify this – the control board will issue a command to shut down the Baksi – the boiler will stop when the alarm is triggered. It is therefore necessary to look for the cause of error e01 in external factors or in the ignition and flame monitoring components.
The recommended procedure described below, based on the principle of proceeding from simple to complex, is the same for all Baksi gas boilers, regardless of the model.
How to diagnose the cause of error E01
Step 1 – Testing the gas pipework
- A typical installation for private homes involves fitting shut-off valves (a tap or valve), a shut-off valve, a meter and a filter to the pipework leading to the boiler. If the property has a gas cooker, it is easy to check that ‘blue fuel’ is coming through: simply light the burner.
What can you do if there’s no flame?
- Check the position of the circuit’s locking controls. It may be that the owner previously shut off the pipes, left the house for a long time and forgot about it. Once the mains power is disconnected, the shut-off valve is activated. Gas pipes are usually fitted with normally closed valves; these are operated manually. These are the most common causes of error code E01 on a Baksi boiler. There is nothing that can be done about the control panel – it is sealed. To check this, we will need to call a representative from the utility company.
With an independent gas supply, the regulator may freeze or burst. There is no need to call in a specialist here – you can sort out the problems yourself.

Autonomous gas supply to a gas boiler
- Insufficient pressure in the pipework is another likely cause of error E01. If the pressure falls below the critical level for the Baksi boiler, the valve will shut off the gas supply to the burner. Professionals use a differential pressure gauge for diagnosis.
The user can determine the pressure level on the same hob. All burners must be lit without exception, and the intensity and stability of the flame tongues must be assessed. It is likely that the gas cylinder or cylinder bank has reached its maximum reserve of ‘blue fuel’. Alternatively, the main filter may be excessively dirty. Simply cleaning it often resolves the Baksi E01 error.
Step 2 – Troubleshooting boiler problems

Diagram of a Baxi boiler
- Ionisation sensor. There are many reasons why no signal from it is reaching the control board. It is not difficult to check this and rectify the problem yourself.
- Chain problem: lack of contact, short circuit or broken wires. If you hear a distinctive clicking sound when trying to ignite the boiler but no spark is visible, this is definitely a fault with the insulation.
- Electrode fouling. Depending on the Baksi series, the electrode is either combined with the ionisation sensor or the two are separate. Cleaning away soot, carbon deposits and dust allows you to resolve boiler error E01. Any alcohol-based liquid can be used to remove these deposits.

Baxi boiler ignition electrode
- Weak spark. There are several possible reasons: incorrect electrode position (the electrode has been ‘knocked out of place’ whilst cleaning the Baksi burner), the gap does not match the factory setting, or a problem with the transformer.
In practice, some ‘tradespeople’, on the advice of so-called experts, bend the electrode to increase the intensity of the spark. This is absolutely out of the question! The gap size is specified in the documentation for the Baksi boiler; simply find the relevant section in the instructions and adjust everything to the correct setting. However, you should not bend the electrode pin (it is fragile), but rather the component that secures it.
- Humidity. If the Baxi is installed in a room with excessive humidity, condensation may form whilst the appliance is out of operation. This causes error code e01. Drying the inside of the boiler (with the casing removed) using a stream of hot air will resolve the problem.
- Burner. It must be serviced regularly. If the boiler is installed in a room with high levels of dust, this should be done more frequently than recommended by the manufacturer, Baksi. The nozzle openings gradually become clogged with dust and soot, reducing the gas flow rate and causing error code E01 to appear. Cleaning the burner is done using a soft brush and a vacuum cleaner – it’s nothing complicated.

Baxi gas boiler burner
- Lack of oxygen. This problem is usually dealt with by other sensors, but when the air intake duct is blocked, it becomes one of the causes of the Baksi E01 error. It is mainly observed when a coaxial flue is connected to the boiler as a result of frost build-up: it will need to be warmed up.

Restricted access to the chimney
- Gas valve … The procedure for adjusting it is set out in the Baksi manual. A fault can be identified by checking the continuity of the winding. The resistance (in kOhm) should be: 2.85 between pins 1 and 2, and <1.35 between pins 4 and 5. It is not difficult to replace it yourself, but you will encounter difficulties with the adjustment: you will need the differential pressure gauge mentioned above. It does not fall into the category of domestic appliances, so you must consult a specialist.
- VK 4105G M – M MainFour gas valve (5702340) Baxi Baxi
- HONEYWELL VK4105M 5033 (5665220) gas valve for Baxi Baxi
- SIT 845 SIGMA gas valve (5653610) Baxi Baxi
Gas valves for Baxi boilers
In fact, this is all a user can do to restore the Baksi boiler to working order when error E01 appears on the display. This error can also be caused by other faults: in the diode bridge, the ignition unit, the gas fittings (valve), or components on the circuit board (capacitors, relays). However, testing such boiler units and troubleshooting is a job for a professional. The control module must not be inspected or repaired at home: this should only be done in a specialist workshop.
Please note!
A new Baksi control board costs between 8,300 and 10,100 roubles (depending on the boiler series). Diagnostics and repair at a service centre cost around 3,400–3,800 roubles (as of 2018).
Electronics
At the heart of the boiler lies sophisticated electronics. It is this system that ensures the appliance operates normally and switches it off in the event of a fault. The automation system informs the owner of a problem by displaying an error code. These alphanumeric codes essentially describe the problem. They indicate what is causing the disruption to the unit’s operation and how the situation can be rectified.
Before we discuss the most common error codes, it is worth noting that DIY interventions and attempts at repair are not the best solution. Troubleshooting without the involvement of a specialist is only permitted within the limits set out in the manufacturer’s instructions.
What is error code E01 in relation to Baxi boilers?

The flame sensor electronics are designed to shut down the boiler in the following situations:
- a disruption to the gas supply or insufficient pressure in the main gas pipeline system;
- ionisation sensor fault;
- compromised integrity of electrical connections or problems with contacts;
- control board fault;
- incorrect connection of the mains supply (boilers are phase-dependent);
- low pressure in the heat exchange system;
- problems with the pump.
How to fix error E01
You can find out how to rectify any Baxi e 01 faults in the user manual, which lists possible problems and explains how to resolve certain faults yourself. If you read the gas boiler operating instructions carefully, you will realise that simply rotating the plug by 180° (phase change) allows you to activate the ignition system. But this is one of the things that anyone can do. However, there are tasks that must still be carried out only by a Gas Master with the necessary experience.
For example, cleaning the contacts can restore the flame monitor’s function. A problem with the pump failing to start may be resolved simply by turning it. A similar situation with the pump occurs when the boiler is first started up, or if there is dirt in a system that is already in operation; this may also be accompanied by error code e01 on a Baksi gas boiler. Low pressure in the heat exchanger may be caused by a low level of the fluid used as the heat transfer medium and by air entering the system.
If, after trying the options listed above and restarting the boiler, it does not restart or switch on in normal mode and error E01 appears on the display, then you will need to call a technician. Repairs relating to a lack of gas supply, low pressure or the gas valve responsible for regulating the gas supply should be carried out by specialists familiar with the specifics of gas equipment operation. Inspections of the electronics, safety control systems and the adjustment of control systems should be carried out by a specialist with extensive practical experience in carrying out similar work on ‘BAXI’ gas boilers of various models. In the case of boilers with combined ignition, a fault in the control board’s electrical circuit may be a possible cause.

You can find plenty of tips on how to resolve any problems that arise. However, according to reviews by experts who provide heating system maintenance and repair services, attempts to fix problems yourself often lead to the complete failure of individual components and the system as a whole.
Automation
The automation of boiler systems is highly varied. Some of these systems are pre-installed by the manufacturer. This category includes all sensors and electronic devices that ensure the safe operation of the system.
The simplest example is a sensor that monitors the normal gas flow. When the gas supply is cut off, the sensor is triggered and the boiler switches off automatically. It will restart once the gas supply is restored.
Systems designed to ensure operational safety also include:

Boiler plant
- Anti-freeze protection (activates when the outside temperature falls below 5 degrees).
- Protection against blockages in the circulation pump system.
- Protection against the three-way mixing valve becoming blocked during prolonged periods of inactivity.
- Protection against limescale build-up in the heat exchanger and boiler.
- Overheating protection.
- Voltage protection in the mains supply.
- Parasitic flame control.
- Checking the combustion and draught.
- Coolant pressure control.
In addition to the pre-installed automatic systems, it is possible to install further electronic equipment:
- Outdoor temperature sensor.
- Room temperature sensor.
- Thermostat.
- Electronic thermostat.
- Remote panels.
- Weather-dependent sensors.
- Remote control buttons.
- Water quality sensors, etc.
Causes of faults during boiler operation
In most cases, error E01 indicates only a few of the reasons listed. The most common is that there is no ignition inside the burner, and a signal is sent directly from the flame control sensor to the main screen of the control panel. This is a simple electrode – a sensor that detects whether there is a flame in the combustion chamber; if there isn’t, the boiler is shut down. The fault occurs regardless of whether the gas supply is fully operational or whether there are faults in the combustion system. The main reasons why error E01 appears in a Baxi boiler are listed below.
- There is no gas supply to the tank, the pressure in the tank is insufficient, or there is a fault with the valve through which air is supplied.
- The boiler’s power supply was connected incorrectly and the phases of this connection are out of sequence (as a rule, all tanks are phase-dependent).
- Loss of signal from the control unit to which the ioniser is connected.
- Dirt or damage to the flame sensor panel inside the tank (the most common fault).
- Control board fault.
- Insufficient draught or a blockage in the air supply to the tank, to ensure proper combustion.
The boiler control system will only stop functioning correctly after three attempts to start the storage tank. The tank will then need to be emptied. To do this, once the faults have been rectified, you must press the R button on the control panel (for ‘Reset’). Users can attempt to check for and rectify certain causes of boiler faults themselves, such as air entering the tank or faults caused by dirt build-up. Below, we will examine all the reasons why a Baxi boiler displays error code E01 and what to do in such a situation.
Errors and their codes

A fracture of the pneumorel
All error codes can be broadly divided into two groups:
- Complete shutdown of the equipment.
- Putting the device into standby mode.
In most cases, a complete shutdown will require the unit to be restarted manually. This will occur in the event of serious faults that may endanger people’s health and lives. … Such faults include a loss of traction, overheating of the equipment, a lack of gas supply, etc. In rare cases, the fault may resolve itself without human intervention, and the automation system will restart the equipment automatically.
Error E01
E01 is one of the most common faults. This code appears when the flame monitor is activated. Possible causes of the fault include:
- Shortage of gas supplies.
- Lack of agreement between phase and neutral in phase-dependent models.
- Lack of contact with the flame sensor.
- A fault or contamination of the sensor itself.
- Faults in the ignition system.
- Fault with the gas valve or the electronic control board.
- Insufficient air supply for normal combustion.
- Insufficient gas pressure in the system.
Gas burner
: If error code E01 appears, you must check that the sensor is connected correctly and that the gas supply is working (often the gas supply is cut off for trivial reasons, such as the gas valve being closed).If these are in order, press the R button for 2–3 seconds. If the error was triggered accidentally, the appliance’s operation will return to normal. If the error recurs, contact the service centre. It is possible that issues with error code E01 are related to the electronics, and any tampering by a non-professional could be fatal to the boiler.
Error E10
E10 is another common problem. Unlike error E01, it is related to the sensors that monitor water circulation in the system and the operation of the pumping unit. The automation system will operate in the following cases:
- A drop in the coolant pressure in the system.
- Lack of contact between the board and the pressure switch.
- Faulty pressure switch.
- Fault with the pump unit sensor.
- Pump fault.
- A blocked filter system in the heating circuit.
- A clogged heat exchanger.
Cause of error E10
It is also not always advisable to fix error E10 yourself. Of course, if the pump is not working, the only way to resolve the problem is to replace it, which is entirely possible to do without the help of specialists. You can clean the filter system yourself. All other faults should be rectified by a specialist.
Errors E96, E97, E98
The occurrence of error codes E96, E97 and E98 indicates only one thing – urgent intervention by a specialist is required. Unlike other faults (E01 or E10), tampering with the boiler’s operation in the event of such faults is strictly prohibited. The reason for this prohibition is simple – these three codes appear when the electronic display is malfunctioning.
The most common error codes for Baxi boilers
The most common error codes for Baxi gas boilers are as follows:
- Error e01 – the cause is a fault in the flame control sensor;
- Error e03 – the traction sensor is at fault;
- Error E25 – temperature sensor faults;
- Error e35 – problem with the flame control electrode.

Baksi boiler error 03e
Below, we will examine the causes of these and other faults in the unit’s operation, and provide recommendations on how to rectify them.
A00
Error code a00 is not an error in itself and appears on the display when the ‘Info’ function is active. This code regularly changes to the inlet temperature reading on the Baxi Luna 3 and Baxi Luna 3 Comfort boilers, as well as the Baxi Ekofor 24,
E00
Error code e00 indicates a fault with the circuit board. You will need to call out a service engineer to repair it.
E01

On the Baxi Mainfour 240F (Mine For 240F), Baxi Main 24 FI (Main 24 FI), Eco Four Baxi, etc., there is no ignition on start-up and no gas supply. The fault was caused by the flame monitor being triggered. Press and hold the ‘R’ button for three seconds. If ignition does not occur, contact the service department.
This may be due to a fault in the ignition system, the electronic control board, an incorrect gas valve setting, a fault with the flue, or a drop in gas pressure in the pipework.
E02
The thermostat has switched off. If nothing happens after pressing and holding the ‘R’ button for a few seconds on Baksi Luna 3 Comfort wall-mounted models, error code e02 is active, and you should also contact a service organisation. This may be caused by the water overheating, a faulty signal from the sensor, a lack of contact between the sensor itself and the coolant, or poor coolant circulation.
E03
On the Baxi Mine 5 and Baxi Mainfour 24 models, error e03 may be caused by an incorrect setting for parameter F43. In other models, this is due to a fault in the thermal relay or draught sensor. This may be caused by blocked flues, failure to follow flue installation guidelines during fitting, or a fault in the fan or pneumatic relay.
The same result will occur if there is no contact between the board and the fan, or between the board and the pneumatic relay. Check that the flue is not blocked and that there is contact on the above-mentioned components. If you are unable to diagnose the cause, call a technician.
E04
The signal is triggered by the flame sensor detecting a periodic loss of flame at the burner. This error (e04) may be caused by a loss of tight contact between the wire and the ionisation electrode, a fault in the flue, a blocked or incorrectly positioned electrode, voltage fluctuations in the mains supply, or a fault in the circuit board.
E05
The signal comes from the heating circuit temperature sensor. When the boiler displays error code e05, it is most likely that either the sensor itself has failed, the circuit board has burnt out, or there is no contact between the sensor and the circuit board. Check the contact on the circuit board and on the sensor.

Boiler temperature sensor
E06
Fault with the hot water supply temperature sensor in a dual-circuit boiler. Error e06 is caused by a faulty sensor, a lack of contact between the circuit board and the sensor, or a fault with the circuit board. You must check the contacts.
E10
This is displayed when there is no signal from the hydraulic pressure switch or when the water pressure sensor is triggered. For the Baxi Main Four, Main 5, Baksi Ekofor 24 F, Eco Four Baxi, Fourtech, Luna-3 and Luna-3 Comfort models, error e10 indicates that the water pressure in the system has dropped, the relay is not functioning, and there is no contact in the relay board.
12E
The occurrence of error code 12e in Baksi slim 1.150 i units indicates the absence of a signal from the differential hydraulic pressure switch. This fault may occur if the heating system is air-locked, the diaphragm is damaged, the pump is blocked or the microswitch is faulty. Check the diaphragm and the pump, and bleed the air from the system.
E25
The temperature is rising too quickly, by more than one degree per second. Error e25 occurs if the batteries in a dual-circuit air-in system are faulty, the pump or heating circuit sensor is damaged, the circuit board is faulty, or there is no contact between the circuit board and the pump’s connecting cable. To rectify this, you must check that the above-mentioned components are functioning correctly.

Mayevsky’s crane for venting air from the battery
E26
The temperature has exceeded the set point by more than 20 degrees. Error e26 occurs for the same reasons as e25 and can be resolved using similar methods.
E27
Incorrect positioning of the temperature sensor in dual-circuit boilers. Error e27 is caused by a fault with the sensor or its incorrect installation. How to rectify this fault: check the sensor’s operation and its position.
E32
Error e32 indicates that a large amount of limescale has built up in the heat exchanger. To resolve this, you must remove the limescale from the heat exchanger. If you wish to clean it using a descaling agent, you must remove the heat exchanger, first drain the water from it and then close the water and gas supply valves.
E35
A parasitic flame will appear until the flame sensor is used to open the gas valve. Error e35 occurs when water is present on the circuit board, the gas valve is depressurised, the mains supply parameters do not meet the requirements specified in the unit’s manual, or the circuit board is out of order. In this situation, installing a stabiliser and earthing is usually the most effective solution.

Boiler plate
E40
A blocked flue or insufficient gas supply pressure. There can be many causes of error code e40; the main ones are a lack of gas, a draught problem in the chimney, insufficient air, malfunctioning ionisation sensors, exhaust fumes, a faulty gas valve, or the hob is not working. You can check the flue yourself; it is best to leave the rest of the diagnosis to a professional.
E41
Error e41 has the same causes and solutions as e40.
E42
Indicates a loss of flame. Error e42 occurs when the flue is blocked, there is no contact between the control board and the fan, the fan is faulty, or the flue installation regulations have not been followed. You can check the draught in the chimney yourself, but for everything else it is best to call in a specialist.
E96
If the mains voltage drops, error code e96 will appear on the Baxi Main Four display. In this case, restarting the unit may help. If the problem persists, contact a specialist from the service company. On the Baxi SLIM unit, this code appears when there is a fault with the control panel. In this case, the only solution is to call a specialist.

Baxi Main Four boiler
E97
If the frequency setting of the power supply signal to the board is incorrect, error e97 will be displayed. To resolve this, change the frequency.
E98
Error e98 occurs when there is a fault in the control unit, usually caused by stuck contacts in the gas supply valve relay. A call to a specialist will help in this situation.
E99
Error e99 is similar to e98, as is the solution.
128
If the flame goes out whilst the boiler is running, error code e128 will be displayed. This happens when the ionisation current parameter is below normal. In this case, you will need to seek assistance from a specialist.
E133

If the gas supply is interrupted, error code e133 will appear on the Baxi Luna HT-1-450 display. To restart the appliance, press and hold the ‘Start’ button for a few seconds.
168
The system displays error code e168 when the power supply is unstable, usually when the voltage spikes. In this case, a specialist is required to identify the specific fault.