The Most Common Boiler Faults and Error Messages: Protherm, Buderus, Attack and More
![]()
Contents
Whether we choose a solid-fuel, gas or electric boiler, they all have one thing in common: a moment can always come when an error message appears. You probably know the feeling: unfamiliar numbers start flashing on the display, sometimes combined with letters. Have you lost the service number, or is nobody answering? Has the instruction booklet gone missing? No problem. We have compiled the most common boiler error messages for exactly these occasions. However, it is always important to contact a service technician who can inspect your boiler professionally, help resolve the issue and prevent further problems. We have therefore also included websites where you can find contact details for a more effective solution.

Boiler Types, Common Faults and How to Prevent Them
There are three basic boiler types in most common use:
- gas boiler
- electric boiler
- solid-fuel boiler
Choosing the right boiler depends on several factors:
- the number of people in the household
- the equipment’s location
- the building’s heat loss
- other factors
It is therefore important to consult a specialist who can help you decide. The right choice prevents many problems and avoids wasted money. Choosing the wrong boiler is a frequent cause of error messages.
The Most Common Boiler Faults
The most common gas boiler faults include:
- a closed gas shut-off valve
- flat batteries in the room thermostat
- a non-working electrical socket near the gas thermostat
- a splitter adapter used in the gas boiler’s electrical socket
- insufficient water in the central heating circuit
- a dusty environment or neglected servicing
Tip: If your boiler is out of action, an electric radiator can provide a temporary alternative. See our review and selection of the best radiators currently on the market.
How to Prevent Boiler Faults
The most important thing is regular boiler servicing. If servicing and preventive inspections are neglected, you can be more than certain that error messages will appear more often. Preventive inspections cost €20–100, but when performed regularly, one per year is sufficient. It is certainly a better investment than buying a new boiler.

Regular preventive inspections help avoid unpleasant faults. A service technician can show you how to respond in emergencies and explain your options. Above all, consider your household’s safety. Find a local service technician and entrust your boiler to them. This is the best way to get rid of boiler error messages.
The Most Common Boiler Error Messages
An unpleasant situation can arise when our heating fails and the house suddenly becomes cold or there is no hot water. The boiler display reports an error and you do not know what to do. The best solution is to call a service technician. Until they arrive, however, you can try checking the basic settings. We have compiled the most common boiler error messages that may also occur in your home.
PROTHERM

Protherm is a German brand within the Vaillant Group that has manufactured boilers in Skalica since 2001. Its water-heating boilers are assembled using electronic work procedures, making assembly easier and reducing the risk of mistakes. They have a large number of brands to their name.
- F0 Loss of Heating Water Pressure — heating water pressure has fallen below 0.6 bar, and the boiler shuts down automatically. Top up the pressure to 1–2 bar, after which the boiler resumes operation itself.
- F1 Return-Pipe Sensor Open Circuit — check that the sensor is connected correctly and has no fault. If correctly connected but not working, call a service technician. The sensor may be damaged.
- F3 Heating Water Temperature Increase — heating water has exceeded the maximum 95 °C. Switch the boiler off and on; operation resumes once the water cools. There may also be a problem with the connection to the cylinder electronics. Check it is correct. If resetting does not help, call a technician. A clogged pump or filter may be responsible. In older boilers, F3 = F20.
- F4 Hot Water Temperature Sensor Open Circuit — the boiler leaves normal operation, and hot water cylinder heating stops. Space heating should not be affected. Check sensor resistance and the cables from the control board to the sensor. If everything is in place, call a technician.
- F5 Outdoor Sensor Fault — the outdoor sensor has probably short-circuited or become disconnected. Check its connection. The fault also appears if weather-dependent boiler control is selected without an outdoor sensor installed. In that case, change the boiler control setting.
- F6 Internal Sensor Open Circuit — check the sensor connection and settings. For this fault, it is best to call service. The sensor may be damaged and need replacement.
- F10 Heating Water Outlet Sensor Short Circuit — check that the sensor is correctly connected and its cable undamaged. If nothing is apparent, call service: the sensor may be faulty and need replacement.
- F20 (F3) Boiler Overheating — the boiler overheated, shuts down and resumes once cool. If the message recurs, call service; the filter may be blocked.
- F22 Insufficient Water — the heating-water system contains too little water, and the boiler shuts down automatically. Top up the heating circuit with the correct amount and reset the boiler. It is best to call a service technician to do this correctly.
- F28 (F1) Flame Loss — the flame went out because gas supply to the boiler was interrupted. Switch it off, wait briefly and switch it on again using the main switch (RESET).
*Messages may differ in older versions: F3 = F20 and F1 = F28.
Service Contact
Avoid problems by contacting service technicians who can advise and help you. On protherm.sk, use the search in Contact: Sales, Installation, Service to find assistance in your area.
BUDERUS

Buderus belongs to Bosch Thermotechnology, as do Junkers and Bosch. Few brands worldwide can boast a history exceeding 280 years. Johann Wilhelm Buderus founded it in 1731 as a foundry near Laubach in Upper Hesse.
Today, Buderus offers comprehensive heating-system solutions for flats and family houses as well as medium and large buildings. These include natural gas and propane equipment and systems using renewable energy. The company also supplies hot water storage cylinders, radiators and controls for every system type, giving customers a complete system from one supplier.
Errors 1…
- “-” (dash) Outdoor Temperature Sensor Not Detected (U054 xx–U154 xx boilers) — check the outdoor sensor and connecting cable for an open circuit, or contact a Buderus service technician; this applies to all error codes.
- “1C” Flue Gas Leakage at the Draught Diverter (U054 xx–U154 xx) — check the flue route and have a chimney sweep inspect it. Check the air supply to the boiler, the entire boiler, heat exchanger cleanliness and gas valve settings. Call a Buderus service technician: this is absolutely essential, as flue gas escaping into the room can cause serious health problems and, in most cases, death of people in the home!!!
- “1C” Flue Gas Sensor Faulty or Unresponsive (GB boilers), or flue gas temperature above 105 °C (GB 022) — replace the flue sensor and check combustion and flue gas temperature. Call a Buderus service technician.
- “1H” Flue Gas Leakage from the Burner Chamber (U054 xx–U154 xx) — check the flue route and have a chimney sweep inspect it. Check boiler air supply, the entire boiler, heat exchanger cleanliness and gas valve settings. Call a Buderus service technician, shut the boiler down and ventilate!
- “1P” Flue Gas Temperature Sensor Not Detected / burner-chamber temperature sensor not detected (U054 xx–U154 xx) — check the flue sensor and cable for an open circuit; do the same for the burner-chamber sensor and cable.
Errors 2…
- “2C” Safety Sensor Above 95 °C (GB112) — check heating water flow through the boiler, bleed it and check pump operation; Buderus service.
- “2E” Heating-System Filling Pressure Too Low — check system pressure and top up to about 1 bar; the heating water pressure sensor may be faulty.
- “2F” Insufficient Temperature Rise After Startup — if temperature has not changed within 13 seconds of burner startup, check sensors and their mounting and the circulation pump. Call a Buderus service technician.
- “2L” No Heating Water Flow Through the Boiler Before Startup / pump not working — check the expected pressure rise as the pump starts. Clean or replace a faulty or blocked heating water pressure sensor. Free or replace a faulty circulation pump; Buderus service.
- “2P” Temperature Gradient Too High (U054 xx–U154 xx), or the flow sensor measured heating water rising by more than 5 °C/s (GB 022, 112) — check expansion vessel filling pressure and top up if needed; check the pump, bypass and return strainer. Check boiler water flow and whether radiators are closed. Call a Buderus service technician.
- “2U” No Heating Water Flow Through the Boiler / the difference between flow and return sensor readings exceeds 40 K — check water flow, pump and return strainer, bleed the boiler and call a Buderus service technician.
- “2Y” Circulation Pump Tachometer Signal Missing — the circulation pump is probably faulty. Call a Buderus service technician.
Errors 3…
- “3A” Fan Speed Too Low (U054–U0154), fan cuts out during operation (GB 132), or fan speed signal unusual for the operating phase (GB022) — check fan and wiring; Buderus service.
- “3C” Fan Not Running (U054–U154), or zero volumetric airflow (GB 132, 122) — check fan cable and connector, replace the fan; Buderus service.
- “3E” Volumetric Airflow Not Interrupted for 24 Hours — the boiler fan is probably faulty.
- “3L” Boiler Fan Not Working — Probably Faulty / fan speed signal missing during preparation or operation (GB 022) — check wiring and replace fan; call a Buderus service technician.
- “3P” Fan Rotating Too Slowly — replace the fan; Buderus service.
- “3U” Differential Pressure Switch Did Not Close During Purging (GB 122) — check wiring and hoses to the differential switch; Buderus service.
- “3Y” Differential Pressure Monitor Does Not Open with Fan Disconnected — check the differential pressure monitor, wiring and connecting hoses. Check the flue too, cleaning or repairing it if necessary; Buderus service.
- “3Y” (GB 022, GB 132) Fan Rotating Too Quickly / fan running too slowly or too quickly — check wiring and replace fan; Buderus service.
Errors 4…
- “4A” Flow Sensor Reports Above 105 °C — check circulation pump operation and heating water flow through the boiler, including strainer, closed heating-line valve and trapped air. Call a Buderus service technician.
- “4C” Emergency Thermostat (STB) Activated — check heating-system pressure, boiler water flow, boiler temperature sensor and pump operation. Bleed the boiler. Check the heat-block temperature limiter and cable for an open circuit and replace if necessary. Do the same for the flue gas temperature limiter and cable. Check and replace the fuse if necessary; Buderus service.
- “4E” Short Circuit Between Safety Sensor and Flow Sensor / or internal error — check wiring and replace sensor; Buderus service.
- “4F” Safety Sensor Above 100 °C (GB 112) — check heating water flow through the boiler, including pump, filter and wiring; check the safety sensor; Buderus service.
- “4L” Safety Sensor Short Circuit / or boiler sensor measured above 130 °C — check boiler wiring and water flow, replace sensor; Buderus service.
- “4P” Loose Contact or Faulty Safety Sensor — check boiler wiring and replace sensor; call a Buderus service technician.
- “4U” Flow Sensor Short Circuit — check boiler wiring and replace sensor; Buderus service.
- “4Y” Outlet Temperature Sensor Faulty — check the temperature sensor and connecting cable; Buderus service.
Errors 5…
- “5C” Logamax plus GB112 Disconnected After Connecting a PC or Handheld Terminal — switch boiler power off and on. If this does not help, call a Buderus service technician.
- “5L” EMS Communication Interrupted (U054 xx–U154 xx) — check connecting cable and controller; Buderus service.
Errors 6…
- “6A” No-Flame Indication / the boiler did not ignite within the safety time — check that gas reaches the boiler, for example by testing the cooker flame. If connected through a splitter adapter, plug the boiler directly into the socket. Check that the condensate trap is clear and inspect ignition and ionisation electrodes and gas valve; Buderus service.
- “6C” Flame Detected After Gas Shutdown / ionisation signal despite no flame — check the ionisation electrode and gas valve assembly and whether a splitter adapter is used; Buderus service.
- “6H” Flame Loss When the Main Gas Valve Opens (GB112) — check gas flow and dynamic pressure, for example for a partly closed gas supply valve. Call a Buderus service technician.
- “6L” Flame Extinguished During Warm-Up / flame loss during operation — check dynamic gas pressure, condensate trap clearance and flue route, including passage and intake/exhaust tightness; Buderus service.
- “6P” Ignition Glow On Too Long — call a Buderus service technician.
Errors 7…
- “7A” UBA Undervoltage or Overvoltage (GB112) — check the electrical connection and remove extension leads and splitters. Verify mains voltage, call a Buderus service technician and an electrician.
- “7C” Mains Power Interrupted After a Fault Message — press the restart button.
- “7F” Faulty F3 Fuse or UBA System Error (GB112) — call a Buderus service technician.
- “7H” UBA Voltage Spike (Overvoltage) — have the electrical installation checked; Buderus service.
- “7L” Timing Error in the UBA Controller — call a Buderus service technician.
Errors 8…
- “8L, 8Y” (GB 112) External Switching Contact Activated (for example, an underfloor heating temperature monitor or low gas pressure) — check whether a safety-chain contact is open; Buderus service.
- “8Y” Jumper 161 on Terminal Block ST8 Not Detected — connector unplugged, jumper missing or external limiter released; Buderus service.
Errors 9…
- “9A” Communication Fault Between UBA and KIM — Buderus service.
- “9A, 9F, 9H, 9P” (GB 112) System Error: Faulty UBA — Buderus service.
- “9C” (GB 112) Incorrect UBA Wiring Connection — check UBA controller wiring; Buderus service.
- “9F” Gas Valve Assembly Contacts Open Circuit — Buderus service.
- “9H” UBA Controller Fault — Buderus service.
- “9L” Control Valve Fault (U054 xx–U154 xx), incorrect gas valve assembly wiring (U054 xx–U154 xx), control panel fault (GB022), open-circuit gas valve contacts (GB022), incorrect gas valve wiring or UBA system error (GB112) — check the control valve and cable; call a Buderus service technician.
- “9P” UBA Controller Fault / control panel fault on GB022 — Buderus service.
- “9U” Faulty KIM — Buderus service.
- “9Y” Communication Fault Between the Logamatic BC10 Base Controller and UBA / gas valve assembly short circuit on GB022 — Buderus service.
Other Errors…
- “C0 (CO)” No Connection to the Internal Water Pressure Sensor / pressure too high at 5.7 bar, or pressure sensor open-circuit or short-circuited — check sensor wiring and replace the pressure sensor.
- “CA” (GB 162) Return Water Temperature 105 °C — check heating water flow, pump and filter; replace the heating water sensor and call a Buderus service technician.
- “CL” (U054 xx–U154 xx) Faulty Hot Water Temperature Sensor / incorrectly fitted hot water sensor — check sensor and cable for an open or short circuit. Check the mounting position; if necessary, remove the sensor and refit it with heat-conducting paste.
- “CP” (U054 xx–U154 xx) Cylinder Sensor Not Detected — check cylinder sensor and connecting cable.
- “CU” Return Water Temperature Sensor Short Circuit — check wiring and heating water sensor; replace the sensor if necessary; Buderus service.
- “CY” Return Water Temperature Sensor Open Circuit (GB 162) — check wiring and sensor; Buderus service.
- “E1, E4, EA, EC” (GB 022) Control Panel Fault — Buderus service.
- “E1, EA, EC, EF, EH, EL, EY” Internal UBA Controller Fault — Buderus service.
- “EA” Burner Controller Fault — Buderus service.
- “EC” (U054 xx–U154 xx) Coding Plug Not Detected / internal error — insert the coding plug correctly, measure and replace it if necessary. Check that connector contacts and ignition wiring are firmly seated; replace the control board if necessary.
- “EF” (GB 022) KIM Contact (EEPROM Platinum Contacts on the Control Panel) loose or short-circuited — Buderus service.
- “EL” (U054 xx–U154 xx) Incorrect Reference Voltage — replace the control board.
- “EP” Fault Reset Button Held for More Than 30 Seconds (U054 xx–U154 xx), or incompatible UBA installed (GB112) — briefly press the fault reset button again, for no more than 30 seconds. Call a Buderus service technician.
- “0Y” (GB 022) Flow Sensor or Safety Thermal Cut-Out Sensor Measured an Instantaneous Temperature Above 95 °C — check sensor wiring and boiler water flow, bleed the system and boiler; the sensor may be faulty. For repeated faults, call a Buderus service technician.
- “P” Appliance Not Defined — set the appliance type using service function E.1.
Service Contact
The descriptions and solutions for boiler faults are for guidance only!!! Avoid problems by contacting trained service technicians who can advise you and help resolve the issue. Use the search on buderus.com/sk to find local assistance. Find the nearest Buderus service technician.
JUNKERS & BOSCH

Junkers focuses on a full range of products in heating technology. It is part of Bosch Thermotechnology. Its products are known worldwide, and it encompasses 7 leading brands.
- A2 Flue Gas Leakage from the Burner Chamber — the heat exchanger must be checked; it may be dirty. Call a service technician.
- A3 Problem with Fan or Pressure Switch Connections — check that connections are correct and undamaged.
- A3 Flue Gas Temperature Sensor Not Detected — check the flue gas safety monitor and its connection.
- A4 Flue Gas Leakage Monitor Damaged — check the flue gas temperature sensor and connecting cables for an open circuit.
- A7 Hot Water Outlet Sensor Problem — check the sensor and its connections are correct.
- A7 Hot Water Temperature Sensor Problem — the temperature sensor may have short-circuited. Check it and call a service technician.
- A9 Hot Water Temperature Sensor Incorrectly Installed — check the mounting position; if necessary, remove the sensor and refit it with heat-conducting paste. A service technician should be called to ensure proper handling.
- CE Low Heating-System Pressure — increase system pressure to 1.5 bar. Call a service technician.
- EA Flame Fault — check that the gas tap is open, gas supply pressure, mains connection, ignition electrodes and cable, and ionisation electrodes and cable. Calling a service technician is best.
Service Contact
For expert advice and proper repair, contact service technicians who will register your boiler and help with problems. At junkers-servis.sk, you can find contacts who will advise on resolving and preventing faults.
VIESSMANN

The Viessmann Group is a German brand that is one of the international manufacturers of heating, industrial and refrigeration systems.
- AB Control Mode – temperature sensor failure. Check the wiring and contact a service technician.
- EE Burner in Fault Mode – the flame is too weak when the burner starts. Check the supply and ignition. Contact a service technician.
- 80 Burner Control Unit in Fault Mode – the system is cooling down. The burner control unit has been locked out and the heating water temperature sensor has short-circuited. Try restarting the boiler. Be sure to contact a service technician.
- A9 Open Them Device Communication Error – check the connection. Contact a service technician if the Open Them device needs replacing.
- F1 Maximum Flue Gas Value Exceeded – check the heating system fill level and circulation pump. The system needs to be bled. Contact a service technician.
- F2 Burner Fault – the control unit is in fault mode and the system is cooling down. Check the heating system fill level and circulation pump, and bleed the system. Restart the appliance and call a service technician.
- F2 Coding Card – the coding card has not been inserted correctly or does not match the control unit.
- F4 Burner Fault – no flame signal. Check the ignition and ionisation electrodes and their connecting cables. Measure the gas pressure and check the gas regulator and ignition. Then restart the boiler.
- F5 Pressure Switch Fault – the pressure switch shows no pressure, there is an electrical connection fault, the gas valve is closed or there are gas supply problems. Contact a service technician.
- F9 Low Speed at Burner Start-Up – check the fan, its connections, power supply and controls. Restart the boiler.
- F10 Exhaust Air Temperature Sensor – the exhaust air temperature sensor is faulty. Contact a service technician.
- FD Burner Control Unit Fault – the system is cooling down and the burner control unit has been locked out. Heating water temperature sensor fault. Contact a service technician.
Service Contact
For your safety and that of your family, find a service technician and prevent problems. You can find information about service technicians in your area at viessmann-partner.sk.
VAILLANT

Vaillant is a German brand that has been on the market for more than 140 years. It has won several awards and continues to improve.
- F20 Temperature Limiter – the wiring is incorrectly positioned or a contact is loose. Check the connection. Call a service technician.
- F22 Water Shortage – there is too little or no water in the boiler, the water pressure sensor is faulty, or the cable to the pump or water sensor is loose or damaged. Call a service technician.
- F24 Temperature Rising Too Quickly – the pump is blocked, pump performance is reduced, there is air in the appliance, the pressure is too low, or the gravity brake is blocked or incorrectly installed. Call a service technician.
- F26 Gas Valve Not Working – check the connection to the gas valve stepper motor. There may also be a problem with the connector on the circuit board or a broken contact. Faulty electronics can also cause this error. Contact a service technician.
- F28 Ignition Failure – the gas meter is not working or the gas pressure monitor has been activated, there is air in the gas, the hydraulic pressure is too low, the condensate route is blocked, the wrong gas nozzle is fitted or the appliance is incorrectly earthed. Try restarting the appliance. Contact a service technician.
- F29 Repeated Ignition Failure – the gas supply has been temporarily interrupted, the condensate route is blocked or the ignition transformer has failed. Restart the appliance. Contact a service technician.
- F36 Flue Gas Circuit Fault – contact a service technician. Flue gases may be escaping into the air.
- F61 Gas Valve Activation Fault – the gas valve cannot be activated. Check the cables and connections. Call a service technician, as the valve may be damaged and need replacing.
- F75 No Pressure Rise Detected When the Pump Starts – the water pressure sensor or pump is faulty, there is air in the heating system or too little water in the appliance. Check the adjustable bypass. Call a service technician.
Service Contact
Do not wait for the boiler to fix itself. Find a specialist in your area and do not risk your safety. On the company website vaillant.sk, use the partner search to easily find a service technician near you who can help resolve the problem and prevent further ones.

ATTACK

A Slovak company that manufactures heating equipment. It has a 19-year tradition and satisfied customers. Its range includes various types of boilers, including gas, solid fuel and pellet boilers, storage tanks and more.
- E02 Boiler Pressure Faults – the boiler pressure is outside the operating limits or the pressure sensor is faulty. Check the pressure and call a service technician.
- A01 Burner Fault – ignition and ionisation electrode fault, a damaged gas valve or a blocked trap. Check the electrode wiring, whether the gas valve is correctly positioned, the gas supply pressure and whether the trap is clean.
- A03 Overheating Protection Activated – the heating sensor is faulty, water is not circulating in the appliance or there is air in the distribution system. Check that the heating sensor is correctly positioned and working, check the circulation pump and filter, or bleed the distribution system.
- F13 Flue Gas Sensor Fault – the sensor is faulty, the cables have short-circuited or the wiring is broken. Check the wiring or replace the sensor. Contact a service technician.
- F37 Incorrect Water Pressure in the Appliance – the pressure is too low: fill the system. The water pressure sensor is not connected or is faulty. Check the pressure sensor.
Service Contact
The best way to resolve a boiler problem is to contact a service technician. The attack.sk website provides a service technician network, where you can easily find help in your area.