Combined gas and solid fuel boiler: types
![]()
Contents
- Gas-fired firewood
- Selection criteria for wood-fired gas boilers
- Coal gas
- Gas, coal and wood
- Characteristics of the operation of gas-fired wood-burning boilers
- Firewood – coal – pellets – gas
- How to ensure long-term operation of a solid-fuel boiler
- Gas pellets
- Do it yourself
- Firewood – pellets – gas
- Pyrolysis
Gas-fired firewood
The advantage of universal gas and wood-burning boilers lies in their autonomy: the system switches seamlessly to burning wood when there is no gas available. Also, if you wish, you can connect an underfloor heating system, as the boilers are supplied with the necessary connections and outlets.

Such universal ‘gas-wood’ boilers can be single-circuit or double-circuit, so it will not be difficult to connect the boiler to a water heating system or a flow-through water heating system.
The disadvantages include the large size of such units. They usually require a separate room for installation and are complicated to service. Such boilers are generally only manufactured as floor-standing models.
Combined gas-wood boilers for domestic use are subject to stricter requirements. The standards and operating regulations are set out in the PPB, SNiP and SP.
A combined gas and wood-fired boiler for a private home comprises the following components:
- Firebox. It is made of cast iron or steel. The boiler may have one or two fireboxes (the latter being more convenient). In the double-firebox version, firewood is burnt in the upper section, whilst a gas burner is fitted in the lower section.
- Hot water and heating circuits. These are manufactured by companies specifically for heating, or for heating to produce hot water (dual-circuit systems). Heating of the hot water supply using the instantaneous heating method.
A universal gas and wood-fired boiler promises savings. This can be seen from the table below.
| Fuel type | Approximate cost per 1 kW of energy, $ | Approximate price per 1 m³, $ | Approximate heating costs for a house with a volume of 450 m³, $ |
| Gas | 0.01 | 0.00047 | 0.2115 |
| Firewood | 0.02 | 0.0094 | 0.423 |
| Coal | 0.055 | 0.002585 | 1.16325 |
| Electricity | 0.03 | 0.00141 | 0.6345 |
| Diesel fuel | 0.04 | 0.00188 | 0.846 |
High-quality wood and gas-fired appliances are manufactured in Russia: “‘Zota MIX’, ‘Kupper PRO’ (‘Teplodar’), ‘Karakan’ (‘STEN’), ‘PARTNЁR’ (‘KOSTER’), ‘STS’ (‘Steel Systems for Solid Fuels’). As well as foreign companies: from Austria and Germany (“Wirbel”), the Finnish group “Jaspi” and others.
It should be noted that with foreign equivalents, it is less common to notice shortcomings in the assembly and automation of the unit. They are characterised by reliability and quality. However, the domestic manufacturer is constantly improving in line with buyers’ wishes.
The prices of ‘wood-gas’ combination boilers depend on the country of origin and the popularity of the brand. For example, a “KOSTER” model will cost an average of 23,000 roubles. Much will depend on the configuration, power rating and other specifications. But a “Jaspi” will set you back as much as 130,000 roubles. That’s a huge price difference, but unlike the Finnish model, where everything is controlled automatically, with the Russian equivalent you’ll have to adjust all the boiler settings yourself.
Selection criteria for wood-fired gas boilers
The key parameter of any heating system is its heat output; choosing the right one ensures a comfortable room temperature at the lowest possible cost. If you are not carrying out complex calculations, then when choosing a boiler you should bear in mind that 1 kW of heat output is required for every 30 m³ in a well-insulated room. A thermal calculation carried out by experts is more accurate and takes into account factors such as the room’s thermal insulation, the presence of other heating systems, and the room’s intended use.
As gas is one of the energy sources for this type of boiler, the pressure in the gas mains should be taken into account. The boiler’s output decreases when the gas pressure is low. In this case, a potential capacity shortfall must be taken into account.
The next important factor to consider when choosing a boiler is its intended use … If the boiler is to be used solely for heating, you can opt for a single-circuit unit. If you need to provide your home with a hot water supply, you should purchase a dual-circuit boiler. There are two types of this equipment: with a built-in boiler or with a built-in coil. The first type always has 40–60 litres of hot water ready. The second type of unit has a smaller hot water capacity than the boiler, but is more compact in size and weight, and is more fuel-efficient. You can always use a single-circuit boiler and connect an indirect heating boiler as an additional option.
When purchasing a boiler, you must ask for an official certificate. Without this document, it will be difficult to register the heating appliance and obtain permission to connect it to the gas supply network.
Coal gas
A universal gas-fired coal boiler is environmentally friendly and low-maintenance. However, if you choose this type of boiler, you will need to keep a constant eye on the level of solid fuel, as the coal runs out quickly. If you suddenly realise that the ‘two-in-one’ option doesn’t suit you, you can always replace the burner – and the boiler will then run on natural gas.
You can find more details about the features of the pellet boiler here.
Most often, a coal- and gas-fired combi boiler is fuelled with wood. For example, in the technical specifications for the ‘Birch B’ double-circuit model, the ‘fuel’ entry states ‘natural gas / coal’ (see table). However, buyers use this type of boiler for heating with firewood.
| Manufacturer and model | Characteristic |
| ATEM (Zhytomyr, Ukraine) Berezka V | The boiler is made of steel; it is versatile and completely independent of electricity. It serves as a cost-effective solution for heating summer cottages, utility rooms and outbuildings. ‘B’ series units are designed to produce domestic hot water. Fuel: natural gas / anthracite (coal). The heated area is 125 m². Rated heat output: 12.5 kW. Maximum gas consumption is 1.5 m³/h. Nominal gas pressure (min/max) – 1274 + 100 Pa (635/1794). Working water pressure – 0.1 MPa. Efficiency when using solid fuel is 78 per cent. Efficiency when using natural gas is 90 per cent. Weight – 119 kg. Domestic hot water consumption – 280 l/h. The combustion chamber is open (chimney). The system is a double-circuit design. |
Gas, coal and wood
The advantage of a gas-wood-coal boiler is that it does not rely on electricity. This allows you to create self-sufficient heating systems. Fuel for such a unit is available anywhere and, moreover, at a low price. The wood-coal-gas boilers from the manufacturers listed in the table below are easy to operate and feature an attractive design.
| Manufacturer and model | Characteristic |
| Hearth KSTG-10 (Russia) | This company has been on the market since 2003. It is a dynamically growing and reliable manufacturer. Boiler type: single-circuit. The combustion chamber is open. Installation – floor-mounted. Heating area – 200 m². Output – 20 kW. Fuel – natural gas. Type of solid fuel – wood, coal. Operating temperature – 95 ºС. Heat exchanger material – steel. Efficiency is 77%. Weight – 70 kg. |
| KSTGV-12.5 fire pit (Russia) | This model of coal, firewood and gas boiler is non-volatile and operates stably even at reduced gas pressure. Thanks to the optimal design of the combustion chamber, the boiler offers high efficiency. Built-in water heater providing hot water. Includes a gas pressure regulator. The boiler casing is resistant to temperature fluctuations. Type – double-circuit. The combustion chamber is open. Installation – floor-mounted. Heating area – 125 m². Output – 12.5 kW. Fuel type – natural gas. Solid fuel types – wood, coal. The boiler is built-in. Operating temperature – 95 ºС. Heat exchanger material – steel. Efficiency – 83%. Automatic shut-off – no. Weight – 120 kg. |
| Raton KS-T-12.5 (Belarus) | These boilers are designed for heating detached houses, buildings and premises equipped with a continuous hot-water heating system featuring natural circulation of the coolant and an open expansion vessel. Type – single-circuit. The combustion chamber is open. Installation – floor-mounted. Heating area – 130 m². Output – 12.5 kW. Type of solid fuel – wood, coal, peat. No display. Heat exchanger material – steel. Ignition is mechanical. Efficiency is 77 per cent. Weight – 138 kg. The service life of the boilers is at least 15 years. |
| Brestselmash KST 12.5 kW (Belarus) | Boilers manufactured by Brestselmash OJSC are classified, in terms of fuel type, as multi-fuel boilers designed to burn solid and gaseous fuels via a conversion process that does not require the boiler to be dismantled. Installation: floor-standing. Heating area: 125 m². Output: 12.5 kW. Fuel: natural gas. Types of solid fuel: wood, coal, peat. No display. Operating temperatures: up to 95 ºС. Heat exchanger material: steel. Efficiency: 90%. Weight – 180 kg. Designed for the supply of heat and hot water to residential and public service buildings equipped with natural circulation water heating systems, with an operating water pressure of up to 0.1 MPa (1.0 kgf/cm²) and a maximum water temperature at the boiler outlet of up to 95 °C. |
| PARTNЁR 24 boiler (Russia) | The advantages of this company’s products lie in their innovative and unique design. The manufacturer guarantees the quality of components, raw materials and other materials. This is a reliable, high-tech production process. The combustion chamber is sealed. Installation: floor-standing. Output: 24 kW. Type of solid fuel: wood, coal. Efficiency: 80%. Weight: 108 kg. Height: 79.5 cm. Width: 42 cm. |
Characteristics of the operation of gas-fired wood-burning boilers
As one of the boiler’s energy sources is solid fuel, it is necessary to keep a close eye on the cleaning of the chimney.
Operating a gas-fired wood-burning boiler involves work relating to the delivery and loading of firewood, and the loading is carried out manually. The boiler will not be in operation for more than four hours.
When buying firewood, its moisture content should be taken into account; this should not exceed 20 per cent. It is better to buy firewood from a specialist shop.
Continuous heating and hot water supply are made possible by automation. If one type of fuel (solid) runs out, the combi boiler automatically switches to the other (gas).
Firewood – coal – pellets – gas
These units are currently offered by: the manufacturer of the ‘Cooper’ universal boiler, which runs on ‘gas, wood, coal and pellets’, and others.
The wide choice of fuels (pellets, firewood, coal, gas) gives this boiler a major advantage. If one type of fuel is unavailable, you can always switch to another and stay warm.
| Manufacturer and model | Characteristic |
| Teplodar Kupper OK15 (Russia) | Boiler type – single-circuit. The combustion chamber is sealed. Installation – floor-mounted. Heating area – 150 m². Output – 15 kW. Fuel type – natural gas. Type of solid fuel – wood, pellets, coal. No display. Efficiency is 78%. Chimney diameter: 150 mm. Weight: 98 kg. Two-stage heating, featuring a removable viewing window that ensures the flame is completely extinguished in the firebox. In addition to the standard water jacket, there is also a heat exchanger in the firebox. Output regulation from 30 to 100 per cent (boilers can be fitted with a combustion controller). Spacious firebox, allowing firewood up to 400 mm in length to be loaded horizontally and 500 mm vertically, or two buckets of coal. The inclusion of a tubular electric heater allows the heating system to be maintained after the fuel has finished burning. |
| Raton KS-TG-35U (Belarus) | Boiler type – single-circuit. The combustion chamber is open. Installation – floor-standing. Heating area – 340 m². Output – 35 kW. Fuel type – natural gas. Type of solid fuel – wood, pellets, coal, peat. No display. Electric ignition. Operating temperature – 95 ºС. Heat exchanger material – steel. Efficiency is 77%. The boiler is designed for heating residential buildings equipped with continuous heating systems with natural or forced circulation of the coolant. |
| Teplodar Uyut-10 (Russia) | “Uyut” is a budget-friendly boiler designed for rooms up to 100 square metres. The firebox is positioned horizontally, allowing the boiler to be fuelled with logs up to 0.5 metres in length. The boiler’s high efficiency is ensured by the original design of the water circuit: stagnant zones are eliminated and the heat transfer surface area is increased to 1.1 m². Option to install a gas or pellet burner. Boiler type – single-circuit. The combustion chamber is sealed. Installation – floor-standing. Heating area – 100 m². Output – 10 kW. Fuel type – natural gas. Type of solid fuel – wood, pellets, coal. No display. Mechanical ignition. Efficiency is 72 per cent. Chimney diameter is 115 mm. Weight – 67 kg. |
How to ensure long-term operation of a solid-fuel boiler
Heating kit
| The set includes: a controller, a fan, a coolant temperature sensor and an 85°C emergency thermostat. |
| Maintaining the boiler’s preset temperature |
| Selection of the heating hysteresis. |
| The fan slows down as the set temperature is reached. |
| Fan speed settings. |
| Protection against condensation and corrosion. |
| Maximum temperature alarm protection (fan shutdown and forced start-up of the pumps). |
| Protection against power loss. |
| Room thermostat app. |
| Maintaining the water temperature in the boiler. |
| Selection of DHW hysteresis. |
| Boiler or heating priority. |
| Summer mode. |
| When you place an order via our website, we will also provide you with a wiring diagram showing how to connect the controller to the fan and the boiler pump. Price: 10,400 ₽ |
Heating + Boiler Set
| The set comprises: a controller, a fan, a coolant temperature sensor, a boiler temperature sensor and an 85°C safety thermostat. |
| Maintaining the boiler’s preset temperature |
| Selection of the heating hysteresis. |
| The fan slows down as the set temperature is reached. |
| Fan speed settings. |
| Protection against condensation and corrosion. |
| Maximum temperature alarm protection (fan shutdown and forced start-up of the pumps). |
| Protection against power loss. |
| Room thermostat app. |
| Maintaining the water temperature in the boiler. |
| Selection of DHW hysteresis. |
| Boiler or heating priority. |
| Summer mode. |
| When you place an order via our website, we will also provide you with a wiring diagram showing how to connect the controller to the fan, the boiler and the boiler pumps. Price: 11,700 ₽ |
Important notices
- A hole must be made in the door of the ash pan (blower) to accommodate the fan.
- The boiler must be sufficiently airtight with the door closed to prevent the fan from blowing combustion products into the room.
- The boiler must also be airtight to ensure that combustion does not continue when the fan switches off and the damper closes.
Application of the ‘Heating’ kit.
We light the boiler and switch on the controller. The fan starts up, blowing air into the combustion chamber. As soon as the boiler has warmed up a little – for example, to the 40°C we have set – the circulation pump switches on. This function protects the boiler from condensation and subsequent corrosion during a cold start. The pump will not stop after this. The boiler must heat up to the operating temperature we have set, for example 70 °C. As it approaches this temperature, the fan begins to slow down and, once the set temperature of 70 °C is reached, the fan switches off. In this case, the damper closes and the flow of air into the boiler stops. Combustion ceases, the pumps draw heat from the boiler and it cools down. We can also set the value by which the boiler temperature must fall for the fan to start running again. For example, 5 degrees. If there is no air supply to the boiler, the temperature will begin to drop. When the temperature drops by the hysteresis value, the fan starts running and the temperature rises again to 70 °C. And to ensure that the boiler does not go out at all during this time, the controller briefly switches on the fan to keep the fuel smouldering.
The “Heating plus DHW” package application.
The controller is already controlling the heating circulation pump, the boiler pump and the fan. The room thermostat is connected. We light the boiler and switch on the controller. The fan starts up, blowing air into the combustion chamber. As soon as the boiler has warmed up slightly – for example, to the 40°C we have set – the heating circulation pump or the boiler pump, or both pumps, will switch on, depending on the priority we have selected. This function protects the boiler from condensation and subsequent corrosion during a cold start. Thereafter, the pump is controlled by the room thermostat and the boiler temperature sensor. The boiler must heat up to the operating temperature we have set, for example 70 °C. As it approaches this temperature, the fan begins to slow down and, once the set temperature of 70 °C is reached, the fan switches off. In this case, the damper opens and the flow of air into the boiler stops. Combustion ceases, the pumps draw heat from the boiler, and the boiler cools down.
The same thing happens when the set room temperature is reached and when the boiler is running at full capacity, regardless of whether the boiler has reached the set temperature or not. The same thing happens when the boiler is operating in summer mode.
We have already mentioned the emergency thermostat. It is fitted in both units. It forces the fan to stop if, for any reason, the temperature of the boiler coolant exceeds 85 °C.
A ready-made solution.
The Lavoro ECO L series boiler is already fitted with an automatic control system and a fan. It is a modern steel hot-water boiler operating in semi-automatic mode. It is designed for heating residential and industrial premises, as well as for domestic hot water (DHW) production. The fuel used includes wood, coal and various types of fuel briquettes. As the boiler is fitted with a modern automatic control system that regulates the air supply via a fan, the burning time per load is significantly increased whilst fuel consumption is reduced. The operating principle is based on the boiler heating water to a preset temperature via a controlled air supply to the furnace; once this temperature is reached, it seamlessly switches to a smouldering (economy) mode. The boiler operates in both closed and open heating systems and is manufactured from 5 mm thick 09G2S steel. All the walls and partitions of the boiler are filled with water. The boiler is fitted with a large, convenient door with a locking mechanism to ensure it is securely fastened. This makes it easy to clean and maintain. All boilers are also fitted with a space for installing an electric heating element. In the standard configuration, the boiler is supplied with a ‘Heating’ controller, which controls the fan and the central heating pump; on request, the boiler can be fitted with a ‘Heating + DHW’ controller, which allows additional control of the boiler pump. All boilers are fitted with a space for installing an electric heating element. In the basic configuration, the boiler is supplied with a ‘Heating’ controller, which controls the fan and the central heating pump; On request, the boiler can be fitted with a ‘Heating + DHW’ controller, which can be used to control the boiler pump as well. All boilers are fitted with a space for installing an electric heating element. In the basic configuration, the boiler is supplied with a ‘Heating’ controller, which controls the fan and the central heating pump; On request, the boiler can be fitted with a ‘Heating + DHW’ controller, which allows additional control of the boiler pump.
Contents of the delivery
Boiler automation Fan Boiler cleaning scraper Grate thermomanometer
- Power output from 12 to 102 kW
- Manufacturer’s price from 49,900 ₽ to 209,900 ₽
When you place an order via our website, you pay the manufacturer directly; you will receive the boiler at the manufacturer’s price, and you will also receive the following from us free of charge:
- The most detailed diagram of the turnkey boiler pipework. You simply need to assemble it according to the diagram; – a detailed equipment list; – a wiring diagram showing the connection of the controller to the fan, the boiler and the boiler pumps. No one else does this apart from us.
Gas pellets
A pellet-gas boiler is a device that can easily switch from heating with one type of fuel to heating with another. This usually takes about 15 minutes.
It is also possible to replace the burner here in the event of a conversion. Tubular electric heaters are available in a wide range of models.
The use of an LPG pressure cylinder is permitted.
The efficiency of the pellet-gas boiler is 90 per cent.
The unit has several combustion chambers. The system comprises two burners and a number of control and shut-off devices. It offers a high level of safety and automation. Nevertheless, like any dual-fuel gas boiler, a gas-pellet boiler requires compliance with PPB and SNiP regulations (some excerpts are described at the beginning of the article).
Don’t forget to clean the boiler from time to time. During maintenance, you should remove any accumulated wood dust and soot from the electric motor and moving parts.
What do you need to work with pellets?
To convert the boiler to run on wood pellets, a pellet burner must be installed and connected to the fuel hopper. Once all the necessary work has been carried out, the boiler operates as follows:
- The pellets are fed into the burner along the conveyor from the fuel hopper;
- Electric ignition occurs instantly via a piezoelectric element;
- A built-in fan is activated in the burner, which increases the pressure, causing the pellets to burn at a high temperature, artificially raised.
Gas-pellet boilers are usually made of cast iron and, given their large size and weight, are mounted on a concrete foundation.
What do you need to work with gas?
Pellet boilers with gas burners are primarily connected to gas cylinders and storage tanks. Such units are becoming increasingly popular in the construction of houses and on plots of land where the installation of mains gas is planned in the near future.
If you wish to connect a gas burner, first close the unused firebox with an airtight lid. You must then install the burner in the space specifically designated for gas appliances. Finally, set the gas flow control switch. That’s it. The whole process took no longer than 15 minutes.

Wirbel ECO-CK 20 combi boiler
Do it yourself
For residents in the private sector, connecting to the gas mains is not a cheap business. Consequently, many try to save money on buying a gas boiler and continue using their solid-fuel boilers by fitting a burner to the lower chamber. However, owners of such heating systems do not fully realise that they will consume much more gas, as solid-fuel boilers are not designed to run on gas, and consequently, such modifications are highly inefficient, as all the heat escapes up the flue – in other words, we are simply heating the street. On the other hand, it is possible to significantly improve the efficiency of a solid-fuel boiler if substantial modifications are made to its design. First and foremost, however, I would like to point out that once these modifications have been made, the boiler can no longer be used for solid-fuel heating.

The essence of the conversion of the KST solid-fuel boiler involves welding steel pipes (1-inch in diameter) above the burner inside the boiler. In this case, the burner flame will not go directly into the flue, but will heat the pipes through which water circulates.
First of all, the boiler must be dismantled and the cladding removed. We will then proceed to the marking stage.
When marking out, it is important to bear in mind a few key points: – Position the pipes at a distance of 30 mm from the burner. – The pipework should be sloped to prevent water from stagnating and boiling inside the pipes. – The pipes must be arranged in 3 rows, spaced 15–20 mm apart.
Using an angle grinder, cut a small window in the water jacket on the outside of the boiler. It is important to cut with a margin so that the pipes can be welded in place later. To drill large holes in the metal for the pipes, use a hole saw with a fluted blade. The diameter of the drill bit must be a few millimetres larger than the diameter of the pipe (in this case, the drill bit diameter is 35 mm for a 1″ pipe) to allow the pipe to be positioned at an angle.
To prevent the crown from overheating and the solder joint from coming loose, you need to keep pouring soapy water over the drilling site as you go. You can use a mineral water bottle with a perforated cork for this purpose.

Drilling a single hole in 3 mm-thick steel takes 20–30 seconds on average; after 3–4 holes, remember to take a break to allow the drill bit to cool down.

As the work is complex and demanding, it is best to weld the pipes using gas welding or semi-automatic equipment.

Once all the pipes have been welded, you can start sealing the water jacket; to do this, weld a stud from the fittings in the centre, which will prevent the boiler from swelling at the repair site in future.

In the final stage, we apply a sealant around the edge of the window we cut out earlier.
Before fitting the casing and installing the boiler in its original position, fill it with water and check that there are no leaks. If a leak is found anywhere, you will need to cut out the opening again and weld the affected areas.
Firewood – pellets – gas
If you are interested in this type of heating system, the table below provides details of a manufacturer of gas, solid fuel and pellet boilers, including their most popular model and a brief description.
| Manufacturer and model | Characteristic |
| Atmos DC 18 SP (Czech Republic) | The new range of ‘ATMOS’ combi boilers: DC 15EP (L), DC 18SP (L), DC 25SP (L), DC 32SP (L) enables environmentally friendly wood combustion based on the generator gasification principle, combined with a burner for pellets, natural gas or extra-light heating oils (depending on which burner is fitted to the boiler). Boiler type – single-circuit. The combustion chamber is open. Installation – floor-standing. Heating area – 300 m². Output – 20.5 kW. Type of solid fuel – firewood, pellets. No display. Boiler – external (optional). Water heater capacity: 78 l. Heat exchanger material – steel. Overheating protection – yes. Frost protection – yes. It has a thermostat. Ignition is mechanical. Efficiency is 92 per cent. Weight – 429 kg. Another advantage of this model is that the boiler takes up less space than many other boilers. |
Atmos DC 18 SP (Czech Republic) Combined boilers for domestic heating are therefore an excellent way not only to keep your home warm, but also to save money. As you always have the option to choose your fuel and switch between them automatically, your home will be heated at any time of the year, even if one particular type of fuel is unavailable. Combined solid fuel and gas boilers are characterised by their reliability, high performance and versatility.
Pyrolysis
Solid-fuel boilers that operate using pyrolytic combustion are marketed as gas boilers. Such boilers are not only reliable and durable, but also offer the highest efficiency of any boilers currently available. Furthermore, it is possible to regulate the output in these boilers, a feature lacking in many other types of heating system.
Such boilers differ from conventional ones in that they burn not only the fuel itself (wood) but also wood gas, which is released from the wood as a result of the increased temperature to which the wood fuel is subjected. As the wood gas is burnt, the formation of soot is completely prevented.
Furthermore, using this type of boiler produces a relatively small amount of ash, which is a rather important feature for any type of boiler. The main disadvantage of boilers of this type is that they need to be connected to the mains to operate, and they are also quite expensive. Such boilers can run on absolutely any type of wood or wood waste. Furthermore, domestic wood-fired boilers are relatively simple to manufacture.

Pyrolysis boiler plant
One of the advantages of gas boilers is that they can operate successfully for 30 hours on a single full load of solid fuel. This operating time is not standard. Like many other things, the operating time of a boiler on a single load of solid fuel depends on a number of factors. These factors include:
- Outdoor air temperature;
- The air temperature in the room itself (its required limits);
- The quality of a building’s insulation and the thermal conductivity of the building materials from which the building’s walls are constructed;
- The type of firewood and its total moisture content;
- The correct installation of the entire heating system and its condition.
But even under the most unfavourable conditions, such a boiler will perform better and more economically than its counterparts. This was made possible by the combustion of wood gas. Burning any type of wood that contains a certain amount of moisture does not produce the same temperature as burning gas.
Furthermore, burning gas requires far less air than burning wood or coal. This affects not only the combustion temperature of the fuel, but also the burning time of the fuel. An important factor is the ability to regulate the boiler’s output relatively easily or to automate this regulation using auxiliary thermostats. A solid-fuel gas boiler thus offers all the functions of electric or gas boilers.