How to Choose a Storage Water Heater by Capacity and Power

Loading

Contents

This article concerns calculating water supply networks in a private house. Since the typical water supply layout of a small cottage is not very complicated, we do not need to venture into a jungle of complex formulas. Readers will, however, need to learn a certain amount of theory.
Part of a private house’s water supply system. Like any other building-services system, it needs preliminary calculations.

Animal repellents Non-destructive
deterrence of
rodents,
wildlife
and snakes.

Features of Cottage Wiring

What actually makes a private house’s water supply simpler than that of an apartment building, apart from the total number of plumbing fixtures?

There are two fundamental differences:

  • With hot water, there is generally no need to provide continuous circulation through risers and heated towel rails.
  • If circulation connections are present, calculating the hot-water network becomes much more complicated: pipes must carry not only the water drawn by residents but also continuously circulating volumes of water.

In our case, the distance from plumbing fixtures to the boiler, water heater or main connection is short enough to disregard how quickly hot water reaches the tap.

Important: For readers unfamiliar with domestic hot-water circulation layouts: in modern apartment buildings, hot-water risers are connected in pairs. A pressure difference at the connections, created by a retaining washer, keeps water circulating through the risers. This ensures rapid hot-water delivery to taps and year-round heating of bathroom towel rails.

The heated towel rail is warmed by continuous circulation through the hot-water risers.

  • The private house’s water supply uses a dead-end layout, meaning a constant load on particular sections of the distribution system. By comparison, a ring water network, where each section can be supplied from two or more sources, must be calculated separately for every possible connection layout.

Other Parameters

The criteria above are the main considerations when choosing a water heater, but other characteristics can influence the model selected, including workmanship, materials and equipment cost. Stainless-steel tanks are considered the most durable. A removable heat exchanger is an important advantage because you can remove it yourself. Avoid equipment using foam rubber as insulation, since this material is very short-lived. The price also directly depends on the manufacturer and the country where the unit was assembled.

A hot-water system makes your home comfortable and cosy. This is easily achieved with a quality water heater. The choice of models is currently wide, and after calculating the necessary parameters, everyone can select equipment offering good value for money.

What We Think

We need to:

  1. Estimate water use during peak demand.
  2. Calculate the cross-section of a water pipe capable of delivering this flow at an acceptable velocity.

Note: the maximum water velocity that does not create hydraulic noise is approximately 1,5 m/s.

  1. Calculate the head at the final fixture. If it is unacceptably low, consider increasing the pipe diameter or installing a booster pump.

Consumption

This can be roughly estimated using consumption rates for individual plumbing fixtures. If needed, the data can easily be found in an appendix to SNiP 2.04.01-85; for convenience, an extract is given below.

Advertisements
Fixture TypeCold-Water Consumption, l/sTotal Hot- and Cold-Water Consumption, l/s
Garden tap0,30,3
Toilet bowl with flush valve1,41,4
Toilet with cistern0,100,10
Shower0,080,12
Bath0,170,25
Kitchen sink0,080,12
Washbasin0,080,12

In apartment buildings, consumption calculations use a probability coefficient for fixtures being used simultaneously. For our purposes, simply add the water consumption of fixtures that can operate together. A washbasin, shower and toilet, for example, give a total flow of 0,12 + 0,12 + 0,10 = 0,34 l/s.

Add the water consumption of fixtures capable of operating simultaneously.

Which Water Heater Should You Choose?

Water heater diagram.

Depending on the task, a suitable water heater can be calculated in two ways. The first considers the stored water volume and calculates the heat-exchanger capacity and power supply. The second calculates the water heater’s volume for storing heat generated over a given time by a source of a given power.

Whichever method is used, water’s storage capacity is always characterised by its heat capacity. This value is constant and equals 4,187 kJ.kg / °C. For example, heating 1 kg of water by 1 °C requires heat equal to 4,187 kJ. This requires 1 163 kWh.

Construction of an electric water heater.

For example, if your water heater holds 1000 litres and the water must be heated to 50 °C, the thermal energy requirement is calculated as follows: 1000 × 50 = 58 kWh.

The heat exchanger’s output depends on the temperature difference between the heating and heated water, as well as its heat-transfer coefficient. Each heat exchanger has its own coefficient, so there can be no universal formula for calculating a water heater. The easiest way to select a heat exchanger is to use the diagrams manufacturers provide in their technical specifications.

With this simple principle in mind, you can consider the individual characteristics.

Standard Electric Water Heater Construction

Diagram of the water heater’s storage tank.

In our country, water heaters and boilers are generally regarded as different devices. In fact, the difference is that the boiler has a tank for heating and storing hot water, which is why technical literature calls them ‘storage water heaters’. They also differ by heat source. Direct and indirect heating systems are currently available. If the device itself generates heat using an electric heating element or gas burner, it is a direct heating system. Indirect heating uses a heat-transfer medium supplied at a certain temperature from a heating boiler. Storage water heaters are the most commonly used; their layout is shown in Figure 1.

Calculation table for a storage water heater.

Before buying a particular water heater, calculate all parameters and consider your home’s characteristics and future operating conditions. Be sure to assess:

  • the condition of electrical wiring;
  • the possible load on the electrical wiring;
  • whether a gas connection is available;
  • the serviceability of all equipment serving the house, including any water pumps.

Installing a storage water heater.

Also consider how many people will use the heater and roughly estimate their daily hot-water consumption. You can then select a particular model.

To choose the right water heater, first determine its main characteristics:

Advertisements
  • the most suitable energy source;
  • the required volume of heated water;
  • heat-transfer fluid consumption;
  • heating time.

The water heater is calculated using these parameters.

Energy Source for Heating Water

Water heater heating circuit.

Gas and electricity are the main energy sources for water heaters. More unusual sources, such as solar panels, also exist but are not very common here. An accurate calculation therefore requires comparing the advantages and disadvantages of gas and electricity.

  1. Electric water heaters are available with power ratings from 1 to 6 kW. Gas water heater output starts at 4 kW.
  2. Gas storage water heaters generally have larger hot-water tanks, up to 150 litres, while electric models rarely exceed 100 litres.
  3. Gas in Russia is much cheaper than electricity.

Diagram of a pressurised water heater.

The choice seems clear, without complicated calculations. Producing 100–150 litres of hot water with a gas heater takes approximately half the time required by an electric system. However, electric units require no additional wiring equipment: a simple socket is enough. Specialists need not be called to install such a heater. A gas water heater, on the other hand, must connect to a gas main, which is not available at every holiday cottage. A chimney is also needed for safe installation.

Prices of water heaters using different energy sources cannot be compared directly. Electric-system costs depend mainly on heating-element power and tank volume. Gas-heater prices depend on the combustion-chamber type, which may be internal or external. Installing an internal-chamber device takes minimal effort and time, but these units cost roughly twice as much as those with an external chamber.

Another condition must be considered: gas water heaters can heat the surrounding air significantly. In holiday cottages and small rooms, this can become a real problem if the heater is installed in the kitchen, for example.

No single recommendation can therefore be made for choosing a water heater with a particular energy source.

Cross-Section

The cross-section of a water pipe can be calculated in two ways:

  1. Selection using a table of values.
  2. Calculation using the maximum permissible flow velocity.

Selection Using a Table

The table really needs no commentary.

Nominal Pipe Bore, mmConsumption, l/s
100,12
150,36
200,72
251,44
322,4
403,6
506

For example, a DN15 pipe is sufficient for a flow of 0,34 l/s.

Note: DN, or nominal bore, approximately equals the internal diameter of water and gas pipes. For polymer pipes labelled by outside diameter, the internal diameter differs by roughly one size: a 40 mm polypropylene pipe, for example, has an internal diameter of approximately 32 mm.

Nominal bore is approximately equal to internal diameter.

Calculating Flow

The diameter of a water supply pipe can be calculated from the water flowing through it using two simple formulas:

  1. The formula for calculating cross-sectional area from its radius.
  2. The formula for calculating flow through a known cross-section at a known velocity.

The first formula is S = π r ^ 2, where:

  • S is the required cross-sectional area.
  • π is pi, approximately 3,1415.
  • r is the cross-sectional radius, half the DN or internal pipe diameter.

The second formula is Q = VS, where:

  • Q — consumption;
  • V is the flow velocity;
  • S is the cross-sectional area.

For easier calculation, all values are converted to SI units: metres, square metres, metres per second and cubic metres per second.

SI units.

Let us calculate the minimum nominal pipe bore ourselves using the following inputs:

  • The flow through it is the same 0,34 litres per second.
  • The flow velocity used in the calculations is the maximum permissible 1,5 m/s.

Let us begin.

  1. The flow in SI units equals 0,00034 m3/s.
  2. According to the second formula, the cross-sectional area must be at least 0,00034 / 1,5 = 0,00027 m2.
  3. According to the first formula, the squared radius is 0,00027 / 3,1415 = 0,000086.
  4. Take the square root of this number. The radius is 0,0092 metres.
  5. To obtain DN or internal diameter, multiply the radius by two. The result is 0,0184 metres or 18 millimetres. As you can easily see, it is close to the result from the first method, though not exactly the same.

Energy Consumption

After deciding that an indirect water heater is needed and calculating its volume, calculate how much hot water is required for everyday living. Consider a family of 4, analysing average daily use over a week and peak demand on a weekday morning.

  1. Weekly Analysis
  • Washing dishes requires approximately 5 litres of hot water per minute. Allow about 5 minutes for rinsing. Washing dishes twice daily uses 50 litres of hot water for kitchenware each day. Multiplied by 7 days, this totals 350 litres per week.
  • Each person bathes 2-3 times weekly, using approximately 170 litres each time. 4 * 2,5 = 10 * 170 = 1700 litres in 7 days.
  • Add another 4-5 showers of 10 minutes at a flow of approximately 12 l/min. 4,5 * 10 * 12 = 540 per family member, or 2 160 litres per week for everyone.
  • Minor hygiene tasks, such as washing hands, cleaning shoes and housework, use approximately 10 litres per person daily, totalling 280 litres over the period studied.

Total: 350 + 1700 + 2160 + 280 = 4490 litres per week. Allowing for guests and contingencies gives approximately 5000 litres weekly. However, the heater is calculated in hours, so convert to those units: 5000/7/24 = 30 litres of hot water per hour, the average consumption of a family of 4.

Using our temperature-to-power data gives the required average energy consumption: 30 * 0,0375 = 1,125 kW/h.

Pressure

Let us begin with a few general observations:

  • Typical pressure in the cold-water supply main is 2 to 4 atmospheres (kgf/cm2)… This depends on the distance to the nearest pumping station or water tower, the terrain, the condition of the main, the type of valves on the main supply and many other factors.
  • The absolute minimum head allowing all modern plumbing fixtures and water-using household appliances to operate is 3 metres… For example, Atmor instantaneous water heater instructions explicitly state that the lower activation threshold of the pressure sensor switching on heating is 0,3 kgf/cm2.

The device’s pressure sensor activates at a head of 3 metres.

For reference: at atmospheric pressure, 10 metres of head corresponds to an excess pressure of 1 kgf/cm2.

In practice, a minimum head of five metres at the final fixture is preferable. A small reserve compensates for unaccounted losses in connections, shut-off valves and the fixture itself.

We need to calculate the head loss in a pipe of known length and diameter. If the difference between the head corresponding to mains pressure and the head loss in the water supply exceeds 5 metres, our system will work perfectly. If it is smaller, increase the pipe diameter or add pumping, whose cost will clearly exceed the additional cost of increasing the pipes by one diameter size.

How, then, is pressure in a water supply network calculated?

The applicable formula is H = iL (1 + K), where:

  • H is the required head-loss value.
  • i is the so-called hydraulic gradient of the pipe.
  • L is the pipe length.
  • K is a coefficient determined by the water supply system’s function.

K is the easiest value to determine.

It equals:

  • 0,3 for domestic and drinking-water purposes.
  • 0,2 for industrial or fire-protection purposes.
  • 0,15 for fire protection and production.
  • 0,10 for firefighting.

The photograph shows a firefighting water supply system.

Measuring a pipe’s length or a section of it presents no particular difficulty, but the concept of hydraulic gradient deserves separate discussion.

Its value is influenced by:

  1. Pipe-wall roughness, which depends on material and age. Plastics have smoother surfaces than steel or cast iron; steel pipes also accumulate scale and rust over time.
  2. Pipe diameter. The relationship is inverse: the smaller the pipe, the greater its resistance to water movement.
  3. Flow velocity. Resistance increases as velocity rises.

Previously, hydraulic losses at valves also had to be considered. Modern full-bore ball valves, however, create roughly the same resistance as the pipe and can safely be disregarded.

An open ball valve offers almost no resistance to water flow.

Calculating hydraulic gradient yourself is difficult, but fortunately unnecessary: all required values are available in the so-called Shevelev tables.

To give readers an idea, below is a small extract from a table for a plastic pipe with a diameter of 20 mm.

Consumption, l/sFlow Velocity, m/s1000i
0,251,24160,5
0,301,49221,8
0,351,74291,6
0,401,99369,5

What is 1000i in the table’s rightmost column? It is simply the hydraulic gradient over 1000 linear metres. To obtain i for our formula, divide it by 1000.

Let us calculate head loss in a 20 mm pipe, 25 metres long, with a flow velocity of one and a half metres per second.

  1. Find the corresponding parameters in the table. For these conditions, 1000i equals 221,8; i = 221,8 / 1 000 = 0,2218.

The Shevelev tables have been reprinted many times since their first edition.

  1. Substitute all values into the formula: H = 0,2218 * 25 * (1 + 0,3) = 7,2085 metres. With an inlet pressure of 2,5 atmospheres, outlet pressure will be 2,5 – (7,2 / 10) = 1,78 kgf/cm2, which is more than satisfactory.

Connecting an Indirect Water Heater with Recirculation

Pipework for different types of indirect water heaters with recirculation is installed according to the drawing. When selecting components, consider the characteristics of the home’s heating system.

The following 3 installation systems can connect the water circuit to the heater:

  1. Installing three-way valves.
  2. Installing a dual circulation pump.
  3. Control using hydraulic separators.

Using fluid recirculation systems significantly increases heating-system performance and improves the efficiency of heating fluid and rooms from boilers.

When installing indirect systems with three-way valves, remember that this method is intended for tanks with increased displacement. The design calculates how a dual-circuit heating installation will be implemented.

Connecting the Water Heater to Boiler Equipment

Monitoring water-temperature information is very important. If the water in heater tanks is set to a much higher temperature than the heating circuits themselves, all equipment may operate incorrectly.

This prevents switching to heating the heating circuits. Indirect water heaters can also be installed using two circuits. The required option also depends on the water in the supply system. If water in the main channel has high hardness, systems with three-way valves are preferable, since dual-circuit systems can quickly fail because of blockages.

Advertisements