No Administrator Access to Your Solar Inverter or Full Control of a Three-Phase Huawei SUN2000?

Loading

Resetting a Huawei SUN2000-(3KTL-12KTL)-M1, (8KTL-20KTL)-M2, (3KTL-20KTL)-M0, (2KTL-6KTL)-L1 Solar Inverter
Do you lack administrator access to your solar inverter or full control of your three-phase Huawei SUN2000 inverter?

 Nedeštruktívne Technoogie ktoré nikde nekúpiš. 

A company commissions and configures your entire solar system, but after a while there is no one available to manage your solar
project? You have to call another company or check the solar system yourself.
But how can you do this if you do not have a password for the Huawei SUN2000 inverter?
Have you been using FusionSolar as a user, without the option to run tests or change parameters?
We will help you unlock all the functions needed for full management of the SUN2000 solar system.
The first step is to physically reset the Huawei SUN2000 inverter.

Before taking this step, however, it is advisable to create an installer account in the FusionSolar app — Installer Registration.
You can then try connecting directly to the SUN2000 inverter through the Huawei Smart Dongle WLAN-FE communication module. Connect via WiFi or Bluetooth.
Launch FusionSolar and sign in as an installer and then add a device,
using Device commissioning rather than Plants, Device, Add. Scan the QR code
on the right-hand side of the SUN2000 inverter. The SUN2000 network and serial number will appear.

Solar inverter password

Select the Installer connection and enter the password.
The default password for the SUN2000 inverter is: 00000a,
or you can also try 00000abc, Solar4Ever, solar4ever, 0000000a, Changeme.
After five attempts, the SUN2000 locks you out for 10 minutes. You can then try other passwords.
If none of them works, your installer has changed the password to their own.

Solar inverter login


Resetting the password on a SUN2000 inverter is very simple. The inverter must, of course, be operational and connected to AC/DC.
Check that the AC and DC power supplies are connected and that the DC and AC indicators are lit continuously green,
or have been flashing slowly for more than 3 minutes.
This means that the DC input voltage is sufficient to reach the inverter’s start-up voltage.
L1=100V DC
M1=200V DC
Step 1.
Then complete the following operations within three minutes!
A. Set both the AC and DC circuit-breaker switches to OFF and wait until all the LEDs on the inverter’s front panel go out.
(This does not refer to the bottom switch on the SUN2000, but to the switches on the AC+DC input circuit breakers.)
Warning
On SUN2000-(3KTL-20KTL)-M0 models, the AC switch must be switched off, and the password can be reset by switching the DC switch ON/OFF.
The battery DC switch on the SUN2000-(2-6KTL)-L1 must be switched off, and the password can be reset by operating the AC and DC switches on the inverter.
B. Set both the AC and DC switches to ON and wait until the LEDs flash green at long intervals.
C. Set both the AC and DC switches to OFF again and wait until the LEDs on the inverter’s front panel go out.
D. Set both the AC and DC switches to ON again. When the LEDs on the inverter’s panel flash slowly green, the password reset has been successful.

Step 2.
Wait for the inverter to restart. When the LEDs flash green at long intervals, the inverter has restarted successfully.
Step 3.
Launch the FusionSolar app on your mobile phone
using the Installer account. After scanning the QR code on the right-hand side of the SUN2000, a window for entering a new password will appear. Enter the password twice.
The password must be reset within 10 minutes. (If you do not change the password within 10 minutes, all parameters will remain as they were before you started the password reset process.)

Sometimes the password is also written above the SUN2000 QR code. However, the password is no longer shown on newer inverter versions.
Set a new password on the app’s login screen and connect to the inverter.

Why is it sometimes advisable to change the SUN2000 password? Particularly if you have a disagreement with your installation company. The solar equipment is your property, so the installer could even have switched it off remotely. This way, they will still have access to it but will no longer be able to make system changes.


Switching a solar inverter off or on remotely Huawei inverters can be started remotely.
Requirements for a technician or installer to switch off the solar system:
The device is connected to the FusionSolar cloud.

Procedure

Solar system shutdown by a technician
On the home screen, select the plant containing the device you want to switch off/on.

Advertisements

Switching off the solar system
Select Device Management > click the inverter’s SN.

Remote shutdown of the solar system
Switch the device on/off using the button shown in the image.

Advertisements
AliExpress

Leave a Reply

Your email address will not be published. Required fields are marked *