Faraday Room and Faraday Cage: Protect Your Privacy with a Specially Built Room
![]()
This is the most effective legal and, at the same time, highly discreet way to protect against information leaks through technical means. If a Faraday room is built to the first or second category described below, there is no need to equip the protected space with detectors, analyzers with memory, walk-through metal detectors or other conspicuous devices beyond the acoustic noise generator and transducers incorporated into its construction.
In principle, this also rules out the possibility of human error found in other ways of securing a space. The principle lies in creating high-quality shielding around the area of interest and adding mains and other filters. Signals from possible eavesdropping devices, compromising computer emissions or other methods of leaking information and data are literally “locked in”: they have nowhere else to propagate. Just as the physical law of conservation of matter applies, so does the law of conservation of energy. What happens to these signals within the space then depends solely on the type of Faraday room or cage and the precision of its construction.

Absorbers incorporated into the construction of a Faraday room or cage ensure that signals striking the absorbing material are converted into thermal energy, significantly reducing the number of signal reflections within the space. Depending on the quality of the absorber, this thermal energy is measurable only at higher power levels, on the order of tens to hundreds of watts, depending on the operating frequency.
In a non-absorptive Faraday room, the signals present are, put simply, attenuated by repeated reflections from the shielding walls. If the room is built using unsuitable technology or inadequate materials, the signals leave the space with a certain undefined attenuation that even differs with each direction of propagation.
Poorly executed, semi-amateur Faraday room designs pose a major security risk because the user mistakenly relies on the space being adequately protected.
Examples of installations in progress.
Among other materials, the designers use a three-layer material to build Faraday rooms. In terms of electromagnetic shielding, it meets the requirements for high-quality shielding of both the electric and magnetic components extremely well. This also provides protection against EMP, a high-energy electromagnetic pulse produced, for example, as a by-product of an uncontrolled chain reaction involving the fission of atomic nuclei, that is, a nuclear explosion. EMP destroys all electronic equipment containing semiconductor components, such as diodes, transistors, integrated circuits and processors, unless it is specially protected, even far from the center of the explosion. The only active electronic components immune to EMP even without protection are vacuum tubes.
The adaptable construction system of a non-absorptive Faraday room allows us to accommodate
clients who cannot select the most suitable space from several alternatives. Power, network and other essential cables are fitted during installation with high-quality filters that prevent hostile signals from penetrating in either direction. Precise workmanship is a reliable guarantee of performance, which we also substantiate with a measurement report prepared by us. Once completed, the room is visually indistinguishable from any ordinary office space, with no obvious signs of special modifications. The construction time depends on the layout, type and size of the space and ranges from 3 to 12 weeks. Prices can start at €350 excluding VAT per cubic meter of protected space.
Faraday rooms and chambers can, of course, also be divided into roughly three groups.
1. Absorptive anechoic chambers or rooms form the first and highest-quality group. Thanks to their construction and choice of materials, they offer the greatest attenuation and are used in radio-frequency laboratories, institutions assessing electromagnetic compatibility, and laboratories carrying out measurements and assessments of antenna radiation patterns and other properties, for example, or compromising emissions from military equipment. Building this type of room requires not only greater financial investment but, above all, a larger space. If absorption is to be sufficiently effective from frequencies on the order of 150 MHz, you must allow for a loss of at least 2 meters of space in every direction, including from the floor and ceiling.
At higher frequencies, this distance is, of course, shorter. Depending on the frequency band, the attenuation of this type of room ranges from -130 dB to beyond -180 dB.
2. Non-absorptive Faraday cages or rooms belonging to the second group are, in terms of their price-to-performance ratio, the most suitable for protection against eavesdropping. If certain technological procedures are followed, suitable materials are used and the installer has the appropriate measuring equipment, their effectiveness fully meets even strict CISPR standards. The attenuation of this type of room is better than -100 dB.
In practice, this means that a high-power eavesdropping device or bug whose signal strength is, for example, -40 dBm at a distance of 10 meters will have a signal strength below -140 dBm at the same distance beyond the wall of a Faraday room. The sensitivity threshold of receivers is usually around -110 to
-120 dBm. Put simply: radio eavesdropping cannot overcome attenuation of this magnitude.
3. “Commercial” Faraday cages, which share only a trade name with a genuine Faraday cage or room, form the last group. They primarily serve as a way for certain operators to make easy money, although that is probably how things work in every field. These are mainly constructions involving copper foil glued to walls, which has only a negligible effect compared with the designs described above.
In promotional materials and descriptions of these designs, it is usually impossible even to find specific attenuation values for particular frequency bands. Another problem is that their designers have no reliable way to measure or check this insertion loss. A relatively costly and time-consuming method is replaced by the use of several types of more or less readily available eavesdropping devices and a practical test of how much their range is reduced. This substitute method provides almost no meaningful information, and it cannot reveal whether a free “window” happens to exist at a neighboring frequency a few MHz away from that of the test device, which could allow a successful information leak. Adding layers of copper foil helps to some extent, but it is still only a slight improvement in the dismal performance of these designs. Paradoxically, the price of this option can often be comparable to, or even higher than, the price of our construction solution. You may also encounter “special coatings” that have slightly absorptive properties, but again, this technology cannot be compared with a genuine Faraday room. For obvious reasons, implementing this technology takes incomparably less time than any of the preceding options.
An Effective Solution for Reliable Protection Against RF Radiation
Exposure to Electromagnetic Radiation
Yarns made from fibers with exceptional properties are turned into fabrics that effectively shield electromagnetic fields. Their shielding performance, which can be adjusted to suit the application, exceeds 80 dB.
The yarns are produced in various forms for home textiles, clothing, industrial and military applications.
Protect Your Sleep and Wellbeing
Electrosmog (EMF) is a collective term for all artificially generated electric, magnetic and electromagnetic fields. Electrosmog is invisible, inaudible and odorless, yet omnipresent. Its sources include all kinds of household electrical installations, high-voltage power lines, induction heaters, computers, Wi-Fi, anti-theft devices, cordless telephones (DECT), mobile phones, baby monitors, television, radar, radio and television broadcasting equipment, wireless communication, smart meters, smart homes and remote controls.
Electromagnetic Radiation Is Increasing
As electricity consumption continues to rise and wireless communication technologies expand rapidly alongside changes in working practices and social behavior, the intensity and volume of radiation increase.
5G: With global mobile data traffic expected to grow eightfold by the end of 2021, a more efficient technology is needed, with higher data rates, greater capacity, better security and more efficient spectrum use. Streaming, autonomous public transport, tracking and monitoring, self-driving cars, drones, security systems and real-time information require continuous wireless access at high speeds and large capacities, without dead zones.
Curtains and Awnings: Highly Effective and Aesthetically Pleasing
Electromagnetic Compatibility (EMC)
as a Prerequisite for Efficiency and Safety
and correctly assess potential risks in good time.
Risks when operating electronic equipment
A host of electronic systems used for diagnostic purposes, monitoring and treatment, surveillance and production in areas such as hospitals or laboratories, military facilities or in industry. Internal or external influences generated by electromagnetic fields can result in significant disturbances and have fatal consequences.
Risks during data processing
Unexpected problems in electronic data processing or time-consuming disruptions of the computer network are phenomena which regrettably are fairly common. To an increasing extent they are due to electromagnetic interference.
Risks for data security
Data security has to be a prime consideration wherever sensitive data are processed. Entire IT systems can be disrupted from outside with relatively little effort. Suitable measures should also be taken to prevent unauthorised access to sensitive data. Using appropriate means, data on computer screens, graphics and video cards can be accessed even without cable connection from as far away as about 100 metres.










